manualshive.com logo in svg
background image

6

Installation and  

Start-Up Procedures

Each water conditioner includes 8’ of drain line.

1. Placement

Place your appliance in desired location. Turn off electricity and water 

supply to water heater. Make sure inlet/outlet and drain connections 

meet the applicable local codes. Check arrows on valve to be sure 

water flows in proper direction.
See Figures 1, 2, & 3 

CAUTION: DO NOT PLUMB APPLIANCE IN BACKWARD.
2. Connecting Water Lines

Lift and remove the valve cover. Attach the water lines to the in and 

out connections. Do not over tighten connections on the plastic 

threads. Check inlet connection and outlet connection to be certain 

water flows in the proper direction. (As you face the front of the 

appliance, the inlet is on the left and the outlet is on the right.) See 

Figure 2

3. Drain Line

The drain line must be a minimum of 

1

2

" I.D. tubing and should make 

the shortest run to a suitable drain. The drain line may be elevated 

up to 8 feet from the discharge on the appliance as long as the water 

pressure in your system is 40 psi or more. If drain line is 25’ or lon-

ger, increase drain line to 

5

8

" I.D. Also, the end of the drain line must 

be equal in height or lower than the control valve. See Figure 1.

4. Flushing

Before placing your appliance in service, it is very important to flush 

the cold water lines of any debris. Turn on water supply, open the 

nearest cold water tap and let the water run for 2 to 3 minutes until 

the water flows clear. Then put the by-pass in the Service position. 

See Figures 4 through 6.

5. Check Leaks

Close faucet and check for leaks. If leaks are found, turn off main 

water supply and open the nearest cold water faucet to depressurize 

lines. Close faucet to eliminate siphoning action. Repair leaks. Turn 

on water supply and electricity to water heater.
Place the bypass valve in the Service position. See Figure 6.

6. Connect Overflow Line

The overflow line is used to direct excess water to a floor drain if the 

brine tank fills with too much water, or the appliance malfunctions. 

The overflow line must end at a drain that is at least 3" lower than the 

bottom of the overflow fitting. It is a gravity line and cannot be run 

overhead. See Figure 7.

7. Complete The Installation

Open a cold water tap and allow the appliance to flush for 20 

minutes or until approximately 72 gallons has passed through the 

appliance per NSF requirements.

8. Plug In Transformer

See Figure 8.

9. Water Testing

The water conditioner, like any other appliance, requires correct 

installation and setting for optimum performance. To ensure proper 

settings, you need to obtain an accurate water test. 

Do this as follows:

For municipally supplied or “City” water, call your water utility compa-

ny. Ask them the hardness, iron content and pH levels of your water.
For well water, have a sample of your untreated water tested for 

hardness, iron and pH. To find a facility to test your water sample, 

check your Yellow Pages under Water Analysis or Water Testing.
If you feel you have an abnormal amount of iron, be sure to use salt 

with an iron-cleaning additive. 

10. Adding Water & Salt 

Be sure to remove any packaging or installation materials before 

adding salt. Next, add no more than 3 gallons of water to the brine 

cabinet. Then add salt to the brine cabinet, wait 2 hours then push 

the REGENERATE button and hold for 5 seconds. A regeneration 

cycle will begin and continue for approximately 27 minutes. After the 

first regeneration, your appliance will automatically refill the correct 

amount of water in the brine cabinet. See Figure 9.

11. Refill Salt 

Refill Salt when the salt level drops below the water level in the brine 

cabinet. Always keep salt above water level. See Figure 9.

CAUTION! Failure to install, operate and maintain your water 

treatment appliance as instructed will VOID the product limited 

warranty.

Содержание PWSCAB30K Pure Water

Страница 1: ...ed for operating parameters to ensure proper use with your water supply Table of Contents Pages How To Get the Maximum Efficiency From Your Appliance 2 Checklist Before Installation 2 Do s and Don ts...

Страница 2: ...ed to verify that your appliance is right for the job See Page 4 3 Water Supply Flow Rate 5 gallons per minute is recommended as minimum 4 Drain Drain appliance to floor drain or washer drain To preve...

Страница 3: ...s Valves To simplify installation and servicing a one piece or a three way by pass valve system is recommended when installing your appliance A bypass system also provides access to untreated water wh...

Страница 4: ...here is a threaded connection to facilitate repairing a potential leak in one of your soldered joints 3 To prevent heat damage to the plastic pipe threads of the adapter prepare the copper tail assemb...

Страница 5: ...5 Reference Illustrations Figure 7 Figure 8 Plugging In Transformer Do not plug transformer into an outlet that is controlled by on off switch Adding Salt To The Brine Cabinet Figure 9...

Страница 6: ...lve in the Service position See Figure 6 6 Connect Overflow Line The overflow line is used to direct excess water to a floor drain if the brine tank fills with too much water or the appliance malfunct...

Страница 7: ...ut ton and hold for 3 seconds The REGENERATE button is used when starting your water conditioner to start an immediate regeneration or to restore capacity if you have run out of salt If your appliance...

Страница 8: ...s Pressing and releasing the SET button will advance programming to the next step 6 If Gallons was chosen 12 is now displayed If Liters was chosen 24 is displayed Pressing and releasing the CHANGE but...

Страница 9: ...9 Controller Layout Figure 10...

Страница 10: ...abinet Figure 11 Item Description QTY 1 Valve Cover Assembly 1 2 Salt Port Cover 1 3 12 Volt Transformer Power Cord 1 4 Cabinet 1 5 2 Piece Overflow 1 6 Brine Tubing 3 8 18 7 Support Panel 1 8 Compute...

Страница 11: ...Adapter Assembly 1 2 3 4 I O Adapter O ring 2 3 Resin Tank Assembly empty 1 4 End Cap O ring 2 5 Drive End Cap Assembly w o motor magnet disc 1 6 Screw 4 7 O ring Small End Cap 1 8 Injector Assembly...

Страница 12: ...The gasket seals at its outer edges and between the inlet screen and nozzle opening These areas must be free of defects such as tears or pits and be free of debris 4 Injector Nozzle 1 Creates the vac...

Страница 13: ...ontroller The three wire assembly connecting the black wafer Hall Effect Sensor or the Controller board must not be severely bent folded over cut or broken Care should be taken when putting the Sensor...

Страница 14: ...Cap When assembling the Drain End Cap to the Main Valve Body care should be taken to make sure the small O ring is aligned with the opening in the Main Valve Body and that the large O ring stays in th...

Страница 15: ...alve retainer 5 push in and turn clockwise to unlock the retainer CAUTION Do not attempt to remove the retainer with the piston assembly in place This will damage the housing and or the retainer Push...

Страница 16: ...ession nuts are tight 2 Guide and Lock Set 1 Should not be loose 3 Float Grommet 2 Should keep float from moving up or down 4 Bell Float 1 5 Float Washer 1 6 Float Rod 1 7 Air Check Brine Well Assembl...

Страница 17: ...17 ITEM NO QTY DESCRIPTION 1 1 Fill Plug 2 2 O ring Parts Diagrams Fill Plug Assembly Tank Bottom Figure 18...

Страница 18: ...sehold plumbing system Repair the leak No read out in display Electric cord is unplugged Plug in transformer No electric power at outlet Check power source Make sure outlet is not controlled by a swit...

Страница 19: ...10 gpm 14 5 Pressure drop service flow rate of 4 gpm 4 0 psi Maximum flow rate to drain during regeneration gpm 2 0 Water Pressure minimum maximum psi 20 120 Controller type 4 Button Regeneration time...

Страница 20: ...warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLEST EXTENT PER...

Отзывы: