Item #

Item

QtY.

DescrIptIon

1

Piston Assembly

1

The Piston should have a gasket on the shaft side of the flange and a spring pressed onto a boss on the other 

side. The gasket should be free of defects such as cuts or debris. The Piston is Teflon coated and should be free of 

scratches. The Piston should move freely in the housing; silicone lubrication is recommended on the Piston shaft.

2

O-ring

1

Seals the brine valve to the drive endcap.

3

Housing

1

Should have a Quad-ring for the Piston seal. The Quad-ring (4) is held in place by the brine valve retainer (5). The 

brine valve housing has four retaining lugs that secure the brine valve retainer. Just inside the entrance hole for 

the Brine Piston (1) is a concave seat area that must be free of defects such as nicks, indentations or debris. If any 

defects are detected by visual inspection, repair or replace as needed.

To replace the Quad-ring, it will be necessary to remove the brine valve housing assembly from the drive end cap 

(after by-passing and depressurizing the conditioning appliance). Push the piston assembly (1) out of the housing. 

To remove the brine valve retainer (5) push in and turn “clockwise” to unlock the retainer. CAUTION! Do not attempt 

to remove the retainer with the piston assembly in place. This will damage the housing and/or the retainer. Push 

the piston back into the housing to dislodge the old Quad-ring (4) and discard it. Remove the piston, insert the new 

Quad-ring and lock the retainer onto the housing by pushing in and turning “counterclockwise” to secure the Quad-

ring. Replace the piston assembly and attach the brine valve assembly to the drive end cap and restore service to 

the conditioning appliance.

4

Quad Ring

1

Seals piston and housing assembly.

5

Quad Ring Retainer

1

Holds quad ring in place.

6

.5 gpm Flow Control

1

The Flow Control has two distinct and different sides. One is “flat;” the other is “concave.” The button should be 

centered in the housing opening with the concave side facing the Housing Cap.

7

O-ring

1

Seals the housing cap to the housing.

8

Housing Cap Assembly

1

Held in place by two 

5

8

"

 machine screws that engage the Housing flange. An O-ring seals the Housing Cap and 

Housing. Place the O-ring into the housing opening, lubricate with silicone grease and then use a twisting action to 

insert the Housing Cap.

9

Clip

1

Locking Clip.

10

Screw

2

Secures housing cap to housing.

Parts Diagrams

Brine Valve Housing Assembly

Figure 16

Содержание PWSCAB30K Pure Water

Страница 1: ...ed for operating parameters to ensure proper use with your water supply Table of Contents Pages How To Get the Maximum Efficiency From Your Appliance 2 Checklist Before Installation 2 Do s and Don ts...

Страница 2: ...ed to verify that your appliance is right for the job See Page 4 3 Water Supply Flow Rate 5 gallons per minute is recommended as minimum 4 Drain Drain appliance to floor drain or washer drain To preve...

Страница 3: ...s Valves To simplify installation and servicing a one piece or a three way by pass valve system is recommended when installing your appliance A bypass system also provides access to untreated water wh...

Страница 4: ...here is a threaded connection to facilitate repairing a potential leak in one of your soldered joints 3 To prevent heat damage to the plastic pipe threads of the adapter prepare the copper tail assemb...

Страница 5: ...5 Reference Illustrations Figure 7 Figure 8 Plugging In Transformer Do not plug transformer into an outlet that is controlled by on off switch Adding Salt To The Brine Cabinet Figure 9...

Страница 6: ...lve in the Service position See Figure 6 6 Connect Overflow Line The overflow line is used to direct excess water to a floor drain if the brine tank fills with too much water or the appliance malfunct...

Страница 7: ...ut ton and hold for 3 seconds The REGENERATE button is used when starting your water conditioner to start an immediate regeneration or to restore capacity if you have run out of salt If your appliance...

Страница 8: ...s Pressing and releasing the SET button will advance programming to the next step 6 If Gallons was chosen 12 is now displayed If Liters was chosen 24 is displayed Pressing and releasing the CHANGE but...

Страница 9: ...9 Controller Layout Figure 10...

Страница 10: ...abinet Figure 11 Item Description QTY 1 Valve Cover Assembly 1 2 Salt Port Cover 1 3 12 Volt Transformer Power Cord 1 4 Cabinet 1 5 2 Piece Overflow 1 6 Brine Tubing 3 8 18 7 Support Panel 1 8 Compute...

Страница 11: ...Adapter Assembly 1 2 3 4 I O Adapter O ring 2 3 Resin Tank Assembly empty 1 4 End Cap O ring 2 5 Drive End Cap Assembly w o motor magnet disc 1 6 Screw 4 7 O ring Small End Cap 1 8 Injector Assembly...

Страница 12: ...The gasket seals at its outer edges and between the inlet screen and nozzle opening These areas must be free of defects such as tears or pits and be free of debris 4 Injector Nozzle 1 Creates the vac...

Страница 13: ...ontroller The three wire assembly connecting the black wafer Hall Effect Sensor or the Controller board must not be severely bent folded over cut or broken Care should be taken when putting the Sensor...

Страница 14: ...Cap When assembling the Drain End Cap to the Main Valve Body care should be taken to make sure the small O ring is aligned with the opening in the Main Valve Body and that the large O ring stays in th...

Страница 15: ...alve retainer 5 push in and turn clockwise to unlock the retainer CAUTION Do not attempt to remove the retainer with the piston assembly in place This will damage the housing and or the retainer Push...

Страница 16: ...ession nuts are tight 2 Guide and Lock Set 1 Should not be loose 3 Float Grommet 2 Should keep float from moving up or down 4 Bell Float 1 5 Float Washer 1 6 Float Rod 1 7 Air Check Brine Well Assembl...

Страница 17: ...17 ITEM NO QTY DESCRIPTION 1 1 Fill Plug 2 2 O ring Parts Diagrams Fill Plug Assembly Tank Bottom Figure 18...

Страница 18: ...sehold plumbing system Repair the leak No read out in display Electric cord is unplugged Plug in transformer No electric power at outlet Check power source Make sure outlet is not controlled by a swit...

Страница 19: ...10 gpm 14 5 Pressure drop service flow rate of 4 gpm 4 0 psi Maximum flow rate to drain during regeneration gpm 2 0 Water Pressure minimum maximum psi 20 120 Controller type 4 Button Regeneration time...

Страница 20: ...warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLEST EXTENT PER...

Отзывы: