Summary of Contents for Basic

Page 1: ...INSTALLATION AND OPERATION INSTRUCTIONS FOR REVERSE OSMOSIS SYSTEMS Basic Premium MetalsMaster BioMaster Other Custom ...

Page 2: ...system assembly bracket should be hung on a wall or sink cabinet side wall with the two screws provided Be sure to either 3 1 Leave enough length of both blue and orange tubing so the system assembly can be lifted off the mounting screws and removed from under the sink for periodic cartridge replacement or 3 2 Leave enough bottom clearance to remove and replace the cartridges from their respective...

Page 3: ...rs The ultraviolet light used for sterilizing is at a specific wavelength 254 nm that destroys or inactivates the DNA of micro organisms to render them harmless Important Safeguards Never look directly at an unshielded UV lamp It can cause permanent eye damage Always wear protective eye wear such as eye glasses or safety glasses Great caution should be exercised when handling a lamp to avoid burns...

Page 4: ...ucet stud 2 2 Place the stud through the hole from the top of the sink or countertop Properly position the faucet handle and faceplate with gasket 2 3 From under the counter slide on the black locating washer used where a 1 2 hole is available or reverse when mounting on stainless steel or when using drilled hole 2 4 Slide on the washer and nut 2 5 Be sure faucet spout and body are in proper posit...

Page 5: ...ainst drilling pressure Do not drill through both sides of the drain pipe If possible place the hole so the drain saddle fitting will angle toward the faucet location 5 3 Position the drain saddle so that the drain fitting is over the hole in the drain pipe 5 4 Tighten the drain saddle screws evenly and firmly so a good seal is made Avoid over tightening Note Some state or local codes may require ...

Page 6: ...d hand tighten firmly 9 6 Reconnect the processed water line by inserting it into the quick connect fitting C 10 Ultraviolet Lamp Installation Systems with the Polisher Biolyte Ultraviolet Sanitizer Only 10 1 Unscrew white cap with silicon plug from stainless steel UV chamber 10 2 Carefully insert bulb into the quartz sleeve Be sure the wire is hanging out of the quartz sleeve 10 3 Push the stoppe...

Page 7: ...o trickle within a few minutes The RO system should now be processing water 4 Close the faucet when water begins to trickle and DO NOT open the faucet again for at least 2 to 3 hours It will take approximately 2 to 3 hours for the holding tank to fill 5 After 2 to 3 hours open the faucet and completely drain the storage tank You should expect air and carbon fines black powder from the carbon filte...

Page 8: ...nged at a minimum every 12 months or earlier if you notice any change in the taste or smell of your water Again your local water professional will be familiar with the quality of your water supply and can offer valuable advice and or periodic testing depending on the quality of your feed water Replacing Filter Cartridges 1 1 Turn off the feed water supply to the RO system assembly Open the RO fauc...

Page 9: ... the processed water line by inserting it into the quick connect fitting 2 10 Slowly turn on the feed water while checking for any leaks WARNING This reverse osmosis membrane contains a preservative solution to prevent microbiological growth and freezing which if ingested may cause irritation of the gastrointestinal tract colic diarrhea or other similar symptoms Therefore 2 to 5 gallons approximat...

Page 10: ...artz sleeve 3 9 Remove silicon plug from cap 3 10 Slide the wire through the hole in the cap 3 11 Carefully screw the cap onto the UV chamber DO NOT CROSS THREAD There is a glow bottle starter attached to the lamp This can be left inside of the cap 3 12 Replace the silicon plug around the wire into the cap 3 13 Plug the wire into the power adapter 3 14 Plug the adapter into the correct power suppl...

Page 11: ...d b Storage tank diaphragm ruptured b Replace storage tank c Tank valve partially closed c Completely open tank valve 3 High TDS product water a Check valve failure on flow control a Replace check valve tee b Membrane fouled hydrolyzed ruptured b Replace membrane or attacked by bacteria c TDS increased in feedwater c Contact dealer for revised product water TDS d Filters weren t flushed properly d...

Page 12: ...he off position or replace valve assembly b Leak around stem O ring seals worn b Replace valve assembly on valve assembly 8 Overflow at faucet air gap a Drain tubing kinked or plugged a Straighten and clean flush drain tubing b Tubing connections are reversed b Check tubing connections and correct c Air gap plugged c Clean with vinegar and or soap d Drain tubing not in downward sloped d Check for ...