SAFETY INFORMATION

This water conditioner’s control valve conforms to UL/CE 

Standards. Generic valves were tested and certified for 

compliance as verified by the agency listing. 

•  Please review the entire Installation and Operation 

Manual before installing the water conditioning system.

•  As with all plumbing projects, it is recommended that 

a trained professional water treatment dealer install 

the water conditioning system. Please follow all local 

plumbing codes for installing this water conditioning 

system.

•  This system will not make microbiologically unsafe water 

safe. Water that is unsafe must be treated separately 

from this conditioner.

•  This water conditioning system is to be used only for 

potable water.

•  Inspect the water conditioning system for carrier shortage 

or shipping damage before beginning installation. 

•  Use only lead-free solder and flux, as required by 

federal and state codes, when installing soldered copper 

plumbing.

•  Use caution when installing soldered metal piping near 

the water conditioning system. Heat can adversely affect 

the plastic control valve and bypass valve.

•  All plastic connections should be hand tightened. Teflon

®

 

tape may be used on connections that do not use an 

O-ring seal. Do not use pipe dope type sealants on the 

valve body. 

Do not use pliers or pipe wrenches.

•  Do not use petroleum-based lubricants such as Vaseline, 

oils or hydrocarbon-based lubricants. Use only 100% 

silicone lubricants.

•  Use only the power transformer supplied with this water 

conditioning system. 

•  All electrical connections must be completed according to 

local codes.

•  The power outlet must be grounded.
•  Install an appropriate grounding strap across the inlet and 

outlet piping of the water conditioning system to ensure 

that a proper ground is maintained. 

•  To disconnect power, unplug the AC adapter from its 

power source.

•  Observe drain line requirements. 
•  Do not support the weight of the system on the control 

valve fittings, plumbing, or the bypass.

•  Do not allow this water conditioning system to freeze. 

Damage from freezing will void this water conditioning 

system’s warranty.

•  Operating ambient temperature:  34° to 120°F  (1° to 

49°C).

•  Operating water temperature: 34° to 100°F  (1° to 38°C).
•  Operating water pressure range : 25 to 120 psi (1.38 

to 8.27 bar). In Canada the acceptable operating water 

pressure range is 25 to 100 psi (1.38 to 6.89 bar).

•  Observe all warnings that appear in this manual.
•  Keep the media tank in the upright position. Do not turn 

upside down or drop. Turning the tank upside down or 

laying the tank on its side can cause media to enter the 

valve.

•  Use only regenerants designed for water conditioning. Do 

not use ice melting salt, block salt or rock salt.

During cold weather it is recommended that the installer warm 

the valve to room temperature before operating.
Teflon

®

 is a trademark of E.I. duPont de Nemours.

HOW TO USE THIS MANUAL

This installation manual is designed to guide the installer 

through the process of installing and starting up water 

conditioning systems featuring the ProSense controller.
This manual is a reference and will not include every system 

installation situation. The person installing this equipment 

should have:

•  Training on the ProSense control valve.
•  Knowledge of water conditioning and how to determine 

proper control settings.

•  Adequate plumbing skills.

PRE-INSTALLATION CONSIDERATIONS

Water Pressure

A minimum of 25 pounds of water pressure is required for 

regeneration valve to operate effectively.

Electrical Facilities

A continuous 115 volt, 60 Hertz current supply is required. 

Make certain the current supply is always hot and cannot be 

turned off with another switch.

Existing Plumbing

Condition of existing plumbing should be free from lime and 

iron buildup. Piping that is built up heavily with lime and/or iron 

should be replaced. If piping is clogged with iron, a separate 

iron filter unit should be installed ahead of the water softener.

Location Of Softener And Drain

The softener should be located close to a drain.

Bypass Valves

Always provide for the installation of a bypass valve.

Tank and Probe Assembly

Use only 100% silicone lubricant on the probe O-rings  

(Figure 2). Do not allow the lubricant to come into contact with 

the probe pins. Install the probe assemblies into the tank and 

secure with the locking clasp (Figure 3). 
Important: The pins on the probes will only fit into the bulkhead 

fittings one way. The pins must go into the matching holes at 

the bottom of the fitting. The probe with the shortest length of 

wire must be on top. 

NOTE: Do not attempt to tighten or loosen the Bulkhead 

fittings as they are secured with a locking 

adhesive.

Lubricate

Probe Pins

Figure 2 

Figure 3 

 

Locking Clasp

Bulkhead Fitting

Содержание IOM-WQ-PROSENSE

Страница 1: ...__________ Model No __________________________________________ Water Test __________________________________________ Capacity Per Unit ____________________________________ Mineral Tank Size __________...

Страница 2: ...8 to 8 27 bar In Canada the acceptable operating water pressure range is 25 to 100 psi 1 38 to 6 89 bar Observe all warnings that appear in this manual Keep the media tank in the upright position Do n...

Страница 3: ...T ADD SALT AT THIS TIME 9 Open the user supplied feed water valve Check for leaks and repair as needed 10 Allow the inside hot and cold faucet to remain open until all air has been purged from the plu...

Страница 4: ...ON TIME when programming the time of regeneration and the days of regeneration 14 The display cursor is next to TIME DAY when programming the current time and day 15 The hourglass is displayed when th...

Страница 5: ...ps carefully as they differ from previous valve instructions NOTE The ProSense controller will be shipped in the service treated water position Do not rotate the camshaft before performing the followi...

Страница 6: ...f f f f 3 3 3 3 to to 18 15 or press then or press press then or press press then or press press then or press press then or press press then press PM f Cubic f Cubic feet f feet Lbs ft 3 Salt Amount...

Страница 7: ...pplications Level IV History H Values Allows access to historical information for troubleshooting the system NOTE If a button is not pushed for thirty seconds the controller returns to normal operatio...

Страница 8: ...Tank Sensors Disabled P14 Refill Rate 1 700 1 1 gpm x 100 Used with salt amount to calculate refill time P15 Draw Rate 1 700 1 1 gpm x 100 Used with salt amount to calculate draw time P16 Flow sensor...

Страница 9: ...in See Notes Automatically calculated from resin volume and salt dosage settings and draw rate C2 Slow Rinse 0 200 See Notes Initial time automatically calculated to provide two bed volumes of rinse C...

Страница 10: ...value is being displayed Program Reset The ProSense controller can be reset to original factory parameters when viewing the H0 parameter Press and hold the SET button for three seconds while H0 is dis...

Страница 11: ...names such as Clorox If stronger solutions are used such as those sold for commercial laundries adjust the dosage accordingly 1 Dosage Polystyrene resin 1 2 fluid ounce 35 5 mL per cubic foot Non resi...

Страница 12: ...and extension cables are used for twin unit parallel and alternating applications Four standard connections are required for operation the power transformer the flow sensor motor optical sensor and th...

Страница 13: ...hrust 14 1 14430 Screw Hex Washer Head 15 2 19160 Screw 6 32 x 3 8 Pan Head 16 2 15172 Scrw Flat Head 17 2 10340 Washer Lock 4 Zinc 18 1 16433 Switch Micro Low DB 19 1 10218 Switch Micro 20 2 15692 Wa...

Страница 14: ...or 1 Natural 23 1 10914 1 Throat Injector 24 1 13303 O ring 021 25 1 15607 Screw Hex Slotted 26 1 25363 Screw Hex WSH HD 27 1 15348 O ring 563 28 1 13173 Retainer DLFC Button 29 1 12085 Washer Flow 1...

Страница 15: ...13287 O ring 123 3 1 14865 Adapter Assy 2nd Tank ProSense 4 1 19054 O ring 124 5 1 40538 Retainer 32mm O ring Dist 7000 6 1 61419 Kit 1 05 Distributor Adapter 7 1 18303 O ring 336 8 4 13255 Clip Mount...

Страница 16: ...12473 Screw Hex Wsh 10 24 x 5 8 3 1 14038 Meter Cap Assy 4 1 13847 O ring 137 Std 560CD Meter 5 1 13509 Impeller Meter 6 4 13314 Screw Slot Ind Hex 8 18 x 60 7 4 13255 Clip Mounting 8 4 13305 O ring 1...

Страница 17: ...3847 O ring 137 STD 560CD Meter 4 1 13509 Impeller Meter 1 13509 01 Impeller Celcon 5 1 13882 Post Meter Impeller 6 1 15043 Body Meter 9000 1 7 1 14960 Flow Straightener 1 8 4 13305 O ring 119 9 2 150...

Страница 18: ...1 1 13399NP By Pass Body 1 NP 2 1 14105 Seal By Pass 560CD 3 1 11972 Plug By Pass w Wax 4 1 11978 Plate By Pass Top 5 1 13604 01 Label By Pass Standard Mount 6 8 15727 Screw Hex Wsh Hd 10 24 x 1 2 7...

Страница 19: ...13305 O ring 119 2 2 13255 Clip Mounting 3 2 13314 Screw Slot Ind Hex 8 18 x 60 4A 1 18706 Yoke 1 NPT Plastic 1 18706 02 Yoke 3 4 NPT Plastic 4B 1 41027 01 Yoke 3 4 NPT Cast Machd 1 41026 01 Yoke 1 N...

Страница 20: ...20 PROBE KIT Item No QTY Part No Description 1 1 30212618 Probe Cable Clips Kit 1...

Страница 21: ...al through drain line A Air in water system A Assure that well system has proper air eliminator control Check for dry well condition B Improperly sized drain line flow control B Check for proper drain...

Страница 22: ...t no dirt or rubbish is clogging any of the cam slots If motor continues to rotate indefinitely replace the following components in this order 1 Wire Harness Motor Home Switch Sensor Assy 2 Controller...

Страница 23: ...23 ProSense METER FLOW DATA...

Страница 24: ...24 ProSense INJECTOR FLOW DATA 1600 SERIES INJECTORS...

Страница 25: ...25 PROSENSE CONTROL VALVE DIMENSIONS...

Страница 26: ...26 WATER CONDITIONER FLOW DIAGRAMS In Service Position Tanks Switching Position Meter Initiated Regeneration Backwash Position Brine Draw Position In Service Position Tanks Switched...

Страница 27: ...27 Slow Rinse Position Rapid Rinse Position Brine Tank Fill Position WATER CONDITIONER FLOW DIAGRAMS continued...

Страница 28: ...ic 60390 Meter Assy 9000 ProSense 1 Ext 60390NP Meter Assy 9000 ProSense 1 Ext N P 60390 20 Meter Assy 9000 ProSense 1 Ext BSP Metric 60612 Meter Assy 9000 ProSense 1 Std Range HW 150 60612NP Meter As...

Страница 29: ...29 SERVICE ASSEMBLIES continued...

Страница 30: ...anties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLEST EXTENT PERMITT...

Отзывы: