10
Level IV Viewing History - H Values
Historical information can be viewed by pressing the SET and
DOWN buttons simultaneously, with the ProSense controller in
the home position. Release both buttons when the controller
displays an “H” value. Press the UP or DOWN buttons to
navigate to each setting.
PROGRAMMING MODE continued
H#
Description
Range
Notes
H0*
Initial Setting Value
Cubic Feet or Liters
Resin Volume, Holding SET for 3 seconds
will reset control to factory defaults
H1
Days since last regeneration
0-255
H2
Current Flow Rate
Depends on turbine used
H3
Water used today in gallons or m
3
since Time of
Regeneration
0-131,070 or 0-1,310.7 m
3
H4
Water used since last regeneration in gallons or m
3
0-131,070 or 0-1,310.7 m
3
H5*
Total water used since reset in 100s
0-999900 gallons or 0-9999m
3
Holding SET key for 3 seconds will reset
H5 and H6 to zero.
H6*
Total water used since reset in 1,000,000
4,294 x 10
6
gal or 4,264 x 10
4
m
3
Holding SET key for 3 seconds will reset
H5 and H6 to zero.
H7
Average usage for Sunday in gallons or m
3
0-131,070 gallons or 0-1,310.70 m
3
H8
Average usage for Monday in gallons or m
3
0-131,070 gallons or 0-1,310.70 m
3
H9
Average usage for Tuesday in gallons or m
3
0-131,070 gallons or 0-1,310.70 m
3
H10
Average usage for Wednesday in gallons or m
3
0-131,070 gallons or 0-1,310.70 m
3
H11
Average usage for Thursday in gallons or m
3
0-131,070 gallons or 0-1,310.70 m
3
H12
Average usage for Friday in gallons or m
3
0-131,070 gallons or 0-1,310.70 m
3
H13
Average usage for Saturday in gallons or m
3
0-131,070 gallons or 0-1,310.70 m
3
H14
Average service cycle
0-255 days
Last 4 Regens
H15*
Peak Flow Rate
0-200 gpm or 1000Lpm
Holding SET key for 3 seconds will reset
H15 to zero.
H16
Day and Time of Peak Flow Rate
Time and day that peak flow occurred
H17*
Months since service
0-2184 months
Holding SET key for 3 seconds will reset
H17, H18 and H19 to zero.
H18
Number of Low Salt Alarms
0-65536
H19
Number of Reduced Capacity Alarms
0-65536
H r
Number of regenerations since last serviced
0-65536
Holding Set key for 3 seconds will reset Hr to zero.
*H0, H5, H6, H15, H17 values can be reset by pressing and holding for 3 seconds while the value is being displayed.
Program Reset
The ProSense controller can be reset to original factory
parameters when viewing the H0 parameter. Press and hold
the SET button for three seconds while H0 is displayed.
Release the button. All settings except for Time of Day and Day
of Week will be reset. The ProSense controller will now display
the resin volume. Refer to Level I Programming.
NOTE: After a program reset all programmed values will
reset to default settings.
Manual Regeneration Options
The ProSense controller features several options that offer
additional flexibility for manually regenerating the softener. On
twin tank systems the tank in standby will move to service.
Then the tank that was in service will be regenerated.
Delayed Manual Regeneration
Press and release the REGEN button to start a delayed
manual regeneration. The Regeneration icon on the display
will flash indicating a regeneration will start when the time of
day reaches the programmed time of regeneration. Pressing
the REGEN button again will turn off the regeneration icon and
cancel the delayed regeneration.
Immediate Manual Regeneration
Pressing and holding the REGEN button for three seconds
starts an immediate manual regeneration. A solid regeneration
icon will be displayed. The controller will immediately begin
a regeneration on the tank in service. To advance to the next
step in the regeneration cycle press and release the SET and
UP buttons simultaneously. To advance the system through all
steps of regeneration and return to service, press and hold the
SET and UP keys simultaneously for three seconds.
Delayed Second Regeneration
Pressing and releasing the REGEN button while the controller
is in regeneration will program the control for a delayed second
regeneration. A flashing x2 icon next to the regeneration icon
will appear indicating a second regeneration will start when
the time of day reaches the programmed time of regeneration.
The delayed second regeneration will be performed on the new
tank in service.
Double Immediate Manual Regeneration
Back-to-Back manual regenerations are initiated by pressing
and holding the REGEN button for three seconds while the
controller is in the regenerating mode. A solid x2 icon next to
the regeneration icon will appear indicating a second manual
regeneration will start immediately after current regeneration is
complete.
Содержание IOM-WQ-PROSENSE
Страница 20: ...20 PROBE KIT Item No QTY Part No Description 1 1 30212618 Probe Cable Clips Kit 1...
Страница 23: ...23 ProSense METER FLOW DATA...
Страница 24: ...24 ProSense INJECTOR FLOW DATA 1600 SERIES INJECTORS...
Страница 25: ...25 PROSENSE CONTROL VALVE DIMENSIONS...
Страница 27: ...27 Slow Rinse Position Rapid Rinse Position Brine Tank Fill Position WATER CONDITIONER FLOW DIAGRAMS continued...
Страница 29: ...29 SERVICE ASSEMBLIES continued...