manualshive.com logo in svg
background image

6

System Specifications

Dimensions - Weights

C

E

F

G

B

D

A

FRONT

HC-200 & HCP-200

SIDE

HCTA-200

C

E

F

G

B

D

A

FRONT

Series HC-200 & HCP-200

NOTICE

Service gpm is for a single mineral tank system ONLY. For HCP-200 Series systems, you will need to 

multiply the Service gpm by (x2) for Duplex, (x3) for Triplex and (x4) for Quadplex systems.

NOTICE

Dimensional data is for a single mineral tank system ONLY. HCP-200 models are composed of multiple HC-200 systems which 

can be arranged accordingly to suit floor space availability. See Space Required in table below for single tank systems and  

estimate 2 spaces for duplex, 3 spaces for triplex and 4 spaces for quadplex HCP-200 series systems.

MODEL NO. 

DIMENSIONS

WEIGHTS

A

B

C

D

E

F

G

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

lbs.

kgs.

M4043B-29NT

67

3

/

8

1711

67

3

/

8

1711

77

7

/

8

1978

16

406

21

1

/

4

538

18

457

40

1016

265

120

M4047B-29NT

67

3

/

4

1721

67

3

/

4

1721

77

1

/

8

1959

17

432

22

1

/

4

564

18

457

40

1016

350

159

M4048B-29NT

68

1

/

2

1740

68

1

/

2

1740 78

15

/

16

2004

18

1

/

8

460

23

1

/

4

589

24

607

41

1041

400

182

M4052B-29NT

70

1

/

2

1791

70

1

/

2

1791 80

15

/

16

2055

21

1

/

8

536

24

11

/

16

627

24

607

50

1270

600

273

M4058B-29NT

76

3

/

4

1949

76

3

/

4

1949

87

1

/

8

2213

24

1

/

8

613

26

1

/

4

665

30

762

50

1270

710

323

M4059B-29NT

80

1

/

4

2038

80

1

/

4

2038

93

1

/

8

2302

30

1

/

8

765

30

1

/

8

764

39

991

48

1219

1160

527

M4060B-29NT

86

2184

86

2184

97

7

/

16

2449

36

1

/

8

917

36

1

/

8

917

39

991

60

1524

1560

709

Series HCTA-200

MODEL NO. 

DIMENSIONS

WEIGHTS

A

B

C

D

E

F

G

in.

in.

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

lbs.

kgs.

M4043TA-29NT

67

3

/

8

1711

67

3

/

8

1711

77

7

/

8

1978

16

406

60

1524

18

457

40

1016

450

205

M4047TA-29NT

67

3

/

4

1721

67

3

/

4

1721

77

1

/

8

1959

17

432

60

1524

18

457

40

1016

500

227 

M4048TA-29NT

68

1

/

2

1740

68

1

/

2

1740

78

15

/

16

2004

18

1

/

8

460

70

1778

24

610

41

1041

800

364

M4052TA-29NT

70

1

/

2

1791

70

1

/

2

1791

80

15

/

16

2055

21

1

/

8

536

75

1905

24

610

50

1270

1200

545 

M4058TA-29NT

76

3

/

4

1949

76

3

/

4

1949

87

1

/

8

2213

24

1

/

8

613

87

2210

30

762

50

1270

1400

636

M4059TA-29NT

80

1

/

4

2038

80

1

/

4

2038

93

1

/

8

2302

30

1

/

8

765

104

2642

39

991

48

1219

2200

1000

M4060TA-29NT

86 

2184

86

2184

97

7

/

16

2449

36

1

/

8

917

115

2921

39

991

60

1524

3000

1364

MODEL NO.

MINERAL TANK

BRINE TANK

SOFTENING

LBS. SALT PER

FLOW RATE & PRESSURE

TANK

RESIN

GRAVEL (LBS)

TANK

SALT

CAPACITY

REGENERATION

SERV

DROP

BKW

SIZE

Ft

3

1/4X1/8 / #20

SIZE

FILL

MAX

MIN

MAX

MIN

GPM

PSI

GPM

M4043B-29NT

14" x 65"

3

- / 60

18" x 40"

400

90 K

60 K

45

18 

25/40

15/25

5

M4047B-29NT

16" x 65"

4

- / 80

18" x 40"

400

120 K

80 K

60

24 

35/55

15/25

7

M4048B-29NT 

18" x 65"

5

- / 100

24" x 41"

600

150 K

100 K

75

30 

57/65

15/25

10

M4052B-29NT

21" x 62"

7

- / 100

24" x 50"

600

210 K

140 K

105

42 

60/77

15/25

12

M4058B-29NT

24" x 72"

10

100 /100

30" x 50"

1200

300 K

200 K

150

60 

74/97

15/25

15

M4059B-29NT

30" x 72"

15 

200 / 200

39" x 48"

2200

450 K

300 K

225

90 

80/100

15/25

25

M4060B-29NT

36" x 72"

20 

300 / 200

39" x 60"

2200

600 K

400 K

300

120 

84/105

15/25

35

Specifications

SIDE

Содержание HC-200 Series

Страница 1: ...Installation Operation and Maintenance 2 Commercial Water Softeners Series HC 200 HCTA 200 HCP 200 HC 200 Simplex Systems HCTA 200 Duplex Alternating Systems HCP 200 Duplex Triplex and Quadplex Progre...

Страница 2: ...ality components Simple programming corrosion resistant mineral tank s and an easy to service design ensures this system will be durable and easy to maintain Thank You The Watts Team Softened water pr...

Страница 3: ...r that is microbiologically unsafe or of unknown quality This system will not make microbiologically unsafe water safe Water that is unsafe must be treated separately from this conditioner Operating a...

Страница 4: ...exchange water softening is a process where an ion exchange resin is used to effectively exchange calcium and magnesium hardness cations for sodium cations in the water New or freshly regenerated ion...

Страница 5: ...neration B System 7 2 Mineral Tanks 1 Meter Immediate Regeneration C System 14 2 8 Mineral Tanks 2 8 Meters Immediate Regeneration Progressive Flow Tank Staging GPM Threshold for Progressive Feature _...

Страница 6: ...2184 977 16 2449 361 8 917 361 8 917 39 991 60 1524 1560 709 Series HCTA 200 MODEL NO DIMENSIONS WEIGHTS A B C D E F G in in in mm in mm in mm in mm in mm in mm lbs kgs M4043TA 29NT 673 8 1711 673 8 1...

Страница 7: ...EL NO ORDERING CODE DESCRIPTION SPACE REQUIRED WEIGHT D X W X H LBS M4043TI NH 68110194 3 Cubic Foot 2 Progressive Duplex Softener with Flow Meters 38 x 55 x 87 530 M4047TI NH 68110195 4 Cubic Foot 2...

Страница 8: ...rding to the diagram below according to your specific series number If any components are missing or damaged contact your Watts representative If they can not be reached contact Watts customer service...

Страница 9: ...with the top of the tank Test the tape cap to make sure it can not come off during the media loading process 4d For systems 24 in diameter and larger fill the mineral tank 1 3 full with water to prev...

Страница 10: ...P14 port s of the control valve controller s See pages 14 15 for P14 location 18 If applicable install a metal bonding strap across metal inlet and outlet plumbing lines to maintain electrical contin...

Страница 11: ...te and local codes Do not construct drain line to elevations that exceed 4 feet above the control valve s drain port 11 The full weight of the piping and valves must be supported by pipe hangers or ot...

Страница 12: ...12 Installation Diagrams Series HCTA 200 Duplex Alternating Systems Top View Side View Front View...

Страница 13: ...13 Installation Diagrams Series HCP 200 Progressive 2 4 Tank Systems Top View Side View Front View...

Страница 14: ...Power Supply 3150 3900 Valves Wire Harness Meter Cable Power Supply Communication Cables Hinge Mount mount per valve model noted 44404 Rev A 44403 Rev A HC 200 HCTA 200 HCP 200 Systems use 2900 2900S...

Страница 15: ...15 Wiring Diagram 44403 Rev A Wiring diagrams are reference only All wiring should be done by a certified electrician and meet all electrical codes...

Страница 16: ...menu navigation Network two to eight valves via shielded CAT5 cables LED Status Indicator Blue In Service Flashing Blue Regeneration Queued Green Regeneration Flashing Green Standby Red Error conditio...

Страница 17: ...17 Controller Display...

Страница 18: ...egeneration If regeneration occurs for any reason prior to the delayed regeneration time the manual regeneration request shall be cleared Pressing the Extra Cycle button while in regeneration will cau...

Страница 19: ...ote Regeneration Ability to trigger a regeneration via a remote input Regeneration Types Softener Filter Meter Delayed When volume remaining reaches zero and the scheduled regeneration time is reached...

Страница 20: ...n the NXT2 circuit board Activates during selected cycle step Activates upon selected start time Range 0 91 minutes Deactivates upon selected end time Range Start Time plus 1 minute Activates when sel...

Страница 21: ...amming certain values may not be able to be viewed or set 7 The controller will display local information not system information 8 In the event of a regeneration occurring while displaying mas ter pro...

Страница 22: ...e button to advance to the next value Press the Left button to retreat to the previous value 3 Where applicable use the Up and Down buttons to adjust a value as desired 4 After progressing through all...

Страница 23: ...splayed When regeneration has been completed the display will return to the main screen Example Real time flow rate reading Example Peak flow since last regeneration Example Gallons at the outlet sinc...

Страница 24: ...n buttons to adjust as desired 3 Press the Extra Cycle button to advance to the Month field Press the Up or Down buttons to adjust as desired 4 Press the Extra Cycle button to advance to the Calendar...

Страница 25: ...X X X X X X X Off Immediate Delayed Auxiliary 1 2 X X X X X X X X X X Off Alarm Based Cycle Based Time Based Lock Window 1 2 X X X X X X X X X X On Off Meter Type X X X X X X X X Paddle 0 75 1 1 5 2...

Страница 26: ...the other end of the hose inside a water permeable bag and locate the bag over the floor drain 14 Insert a garden hose into the bag side of the poly vinyl hose to fill the hose and PVC pipe with wate...

Страница 27: ...ON 5 0 GPM F 14 SOFTENER 3 1 68108571 V7103 07 FC BUTTON 7 0 GPM F 16 SOFTENER 3 1 68108574 V7103 10 FC BUTTON 10 0 GPM F 18 SOFTENER 3 1 68108575 V7103 12 FC BUTTON 12 0 GPM F 21 SOFTENER 3 1 6810857...

Страница 28: ...3E BRINE TANK ASSY 24X41 BLK W GRID AIR CHECK FOR 1 2 BRINE HOSE 13 1 68102503 G2004B BRINE TANK ASSY 24X50 BLK W GRID AIR CHECK FOR 1 2 BRINE HOSE 13 1 68102512 G2009A BRINE TANK ASSY 30X50 BLK W AIR...

Страница 29: ...00 Upper Powerhead 2900 UPPER POWERHEAD ITEM NO QTY PART NUMBER DESCRIPTION 1 1 68104633 K4560410 NT UPPER POWERHEAD F 2900S 24V NXT2 W POWER SUPPLY NO TIMER 2 1 68104575 K4560219 02 COVER FOR 2750 29...

Страница 30: ...30 NXT2 Controller Assembly NXT2 CONTROLLER ASSEMBLY ITEM NO QTY PART NUMBER DESCRIPTION 1 1 68104777 K4562115 CONTROLLER ASSEMBLY NXT2 1...

Страница 31: ...31 NXT to NXT2 Conversion Kit NXT TO NXT2 CONVERSION KIT ITEM NO QTY PART NUMBER DESCRIPTION 1 1 68104778 K4562121 01 CONTROLLER ASSY CONV KIT NXT TO NXT2 W 24V US POWER SUPPLY 1...

Страница 32: ...rts 2900 Lower Powerhead 2900 LOWER POWERHEAD ITEM NO QTY PART NUMBER DESCRIPTION 1 1 68104635 K4560411 NT LOWER POWERHEAD F 2900S 24V NTXT2 NO COVER 2 1 68104574 K4560217 02 COVER FOR 2900 LOWER POWE...

Страница 33: ...DOWNFLOW F 2900S UPPER 4 1 68104546 K4560128 SEAL SPACER KIT F 2900S LOWER 5 1 68104732 K4561550 PISTON ASSEMBLY DOWNFLOW HWBP F 2900S LOWER 5 1 68104733 K4561555 PISTON ASSEMBLY DOWNFLOW NHWBP F 2900...

Страница 34: ...BRINE FLOW WASHER 25 GPM 5 1 68104118 K4512095 BRINE FLOW WASHER 50 GPM 5 1 68104119 K4512097 BRINE FLOW WASHER 1 0 GPM 6 1 68104079 K4510913 00 INJECTOR NOZZLE 00 VIOLET 6 1 68104080 K4510913 000 INJ...

Страница 35: ...00 INJECTOR NOZZLE 00 VIOLET 5 1 68104080 K4510913 000 INJECTOR NOZZLE 000 BROWN 5 1 68104081 K4510913 BL INJECTOR NOZZLE 2 BLUE 5 1 68104082 K4510913 G INJECTOR NOZZLE 4 GREEN 5 1 68104083 K4510913 R...

Страница 36: ...1 7CB INJECTOR NOZZLE 7C BLACK 3 1 68104214 K4514802 3Y INJECTOR THROAT 3C YELLOW 3 1 68104215 K4514802 4G INJECTOR THROAT 4C GREEN 3 1 68104216 K4514802 5W INJECTOR THROAT 5C WHITE 3 1 68104217 K4514...

Страница 37: ...04109 K4512085 FLOW CONTROL WASHER 1 2 GPM 2 1 68104110 K4512086 FLOW CONTROL WASHER 1 5 GPM 2 1 68104111 K4512087 FLOW CONTROL WASHER 2 0 GPM 2 1 68104112 K4512088 FLOW CONTROL WASHER 2 4 GPM 2 1 681...

Страница 38: ...h Electronic Meter 2 INCH STAINLESS STEEL METER ASSY ITEM NO QTY PART NUMBER DESCRIPTION 1 1 68104756 K4561934 10 METER ASSEMBLY COMPLETE 2 STAINLESS STEEL MECH ELEC 2 1 68104199 K4514716 METER DOME P...

Страница 39: ...generation Inlet of control plugged due to foreign material broken loose from pipes by recent work done on plumbing system Remove piston and clean control valve Loss of mineral through drain line Air...

Страница 40: ...ected system type in Master Programming Push correct valve settings in Master Settings Motor Stall No Changes Detected in the Optical Sensor for 6 Seconds The motor is on but no encoder pulses are det...

Страница 41: ...41 Water Softener Flow Diagrams Down Flow Brining 2 Backwash Position 3 Brine Position 4 Slow Rinse Position 5 Rapid Rinse Position 6 Brine Tank Refill Position 1 Service Position...

Страница 42: ...42 Water Softener Flow Diagrams Up Flow Brining 2 Brine Position 3 Slow Rinse Position 4 Backwash Position 5 Rapid Rinse Position 6 Brine Tank Fill Position 1 Service Position...

Страница 43: ...43 Flow Data and Injector Draw Rates Down Flow...

Страница 44: ...ilox Micro Z and neutralizing media are also not covered by this warranty In the event of a covered defect within the warranty period the Company will at its option replace or recondition the product...

Отзывы: