5
Installation
S19-921
Bradley •
215-1546 Rev. U: ECO 23-05-022B 1/3/2024
Step 3: Test Eyewash Unit
1 . After completing installation, test the eyewash station for proper
operation by pulling down the tray . Check for proper water
flow and quickly close the tray . Visually inspect the eyewash
unit weekly for cleanliness and proper solution level (per ANSI
Standard Z358 .1-2014) . When the water level drops below the
15-minute fill line, the tank must be emptied and then refilled .
To refill the eyewash tank, follow the procedures outlined in Step 2
found on page 4 .
2 . Attach the eyewash inspection tag (supplied) to the eyewash
unit . This tag is to be used for weekly inspection documentation .
Hook-and-loop fasteners are provided to attach the tag to the unit .
3 . If the eyewash unit is not working properly, remove it from the
hazard area and contact Bradley Company immediately .
Clamp
Latch
Cap
Pedestal
Pierce
Tank
Snorkel
Drain Hole