background image

Page 2

  
 
 
 
  

 

 

 

 
 
 

 
 

 

Thank you for your purchase of a state of the art Premier Reverse Osmosis (RO) water treatment system.

 Water 

quality concerns are becoming more of a focus for the public.  You may have heard about contaminants in the drinking 

water such as Arsenic, Chromium, Cryptosporidium or Giardia.  There may also be some local water issues such as 

high levels of Lead and Copper. This Premier water treatment system has been designed and tested to provide you 

with high quality drinking water for years to come.  The following is a brief overview of the system.

Your Reverse Osmosis System:

Osmosis is the process of water passing through a semi permeable membrane in order to balance the concentration 

of contaminants on each side of the membrane. A semi permeable membrane is a barrier that will pass only certain 

particles like clean drinking water, but not other particles like arsenic and lead. 

Reverse osmosis uses a semi permeable membrane; however, by applying pressure across the membrane, it 
concentrates contaminants (like a strainer) on one side of the membrane, producing crystal clear water on the other. 

This is why RO systems produce both clean drinking water and rinse water that is flushed from the system. This reverse 

osmosis system also utilizes carbon block filtration technology, and can therefore provide a higher quality drinking 

water than carbon filtration systems alone. 

Your system is a four stage RO which is based upon separate treatment segments within the one complete water 

filtration system. These stages are as follows:

  

Stage 1 – Sediment filter, recommended change 6 months.

The first stage of your RO system is a five micron sediment filter that traps sediment and other particulate 

matter like dirt, silt and rust which affect the taste and appearance of your water. 

Stage 2 – Carbon filter, recommended change 6 months.

The second stage contains a 5 micron carbon block filter.  This helps ensure that chlorine and other materials 

that cause bad taste and odor are greatly reduced.  

Stage 3- Membrane, recommended change 2-5 years.

Stage three is the heart of the reverse osmosis system, the 50GPD (Gallons Per Day) RO membrane.  This 

semi permeable membrane will effectively remove TDS,  Sodium and a wide range of contaminants such 

as Chromium, Arsenic, Copper, Lead as well as Cysts, such as Giardia and Cryptosporidium.  Because the 

process of extracting this high quality drinking water takes time, your RO water treatment system is equipped 
with a storage tank. 

Stage 4- VOC Block filter, recommend change 12 months.

 

 Premier RO-Pure Plus system conforms to NSF/ANSI 58 for VOC reduction. Through the specialty (VOC) 

like MTBE’s, Atrazine, Benzene, 2,4-D,Lindane and others from your drinking water. It is estimated that 

VOC’s are present in one-fifth of the nation’s water supplies. These water contaminants can enter ground 

water   from a variety of sources including localized use of herbicides and pesticides, gasoline or oil spills, 
leaking underground fuel tanks, septic system cleaners, and chemicals used in the dry-cleaning industry. 
See performance data sheet for individual contaminants and reduction performance.

Note: 

Filter & Membrane life may vary based upon local water conditions and/or use patterns.

System Maintenance

Just because you cannot taste it, does not mean that it is not there. Contaminants such as Lead, Chromium and Arsenic 

are undetectable to the taste.  Additionally, over time if you do not replace the filter elements, other bad tastes and 

odors will be apparent in your drinking water.  

It is important to change out your filters at the recommended intervals as indicated in this system manual.  When 

replacing the filter elements, pay special attention to any cleaning instructions. Should you have any further questions 

please refer to our web site at 

www.premierH2o.com

 or call our customer service department at 

1-800-752-5582.

Содержание RO-PURE Plus

Страница 1: ...r failure to follow any attached instructions or operating parameters may lead to the product s failure Model RO PURE Plus System Tested and certified by WQA against NSF ANSI Standard 58 for the reduc...

Страница 2: ...nge 6 months The second stage contains a 5 micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane recommended...

Страница 3: ...ion 9 Drain Saddle Tube Connection 9 Blue Tube Connection 10 Red Tube Connection 10 Green Tube Connection 11 Reverse Osmosis Module Mounting 11 Tank Ball Valve Installation 11 Blue Tube Connection Fro...

Страница 4: ...aximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5 NTU Hardness Maximum 10 Grains Per Gallon Hardness Recommended hardness not to exceed 10 grains per gallon or 1...

Страница 5: ...LUE TUBING WITH 90 BEND 4FT 11 400048 3 8 BLACK TUBING 3FT X 1 12 142002 1 4 RED TUBING WITH 90 BEND 4FT 13 105311 SEDIMENT PRE FILTER RED 14 105351 CARBON PRE FILTER YELLOW 15 105331 REVERSE OSMOSIS...

Страница 6: ...hen drilling Watts accepts no responsibility for damage resulting from the installation of faucet Diamond tip bit recommended Marble Counter top We recommend contacting a qualified contractor for dril...

Страница 7: ...e lubricant if needed Assemble Faucet Figure C 7 Align the release button on the back of the upper faucet assembly approximately 45 left off the back of the lower faucet assembly 8 Press the upper fau...

Страница 8: ...pter no washer 1 Brass Adapter with black washer 1 White rubber washer Make sure that the black collet is installed in to the 1 4 opening on the Adapt a valve Don t forget to install the white compres...

Страница 9: ...second drain Installation of the drain saddle near a garbage disposal may cause the drain line to plug If no other installation of drain line is available Premier offers drain line installation kit pa...

Страница 10: ...E THE FLOW RESTRICTOR OR CUT THE RED TUBING AS IT WILL DAMAGE THE FLOW RESTRICTOR Blue Tube Connection From FAUCET To The RO Module Locate the 1 4 BLUE tube from the RO faucet Insert the open end of t...

Страница 11: ...uick connect ball valve supplied in the parts bag onto the stainless steel connector on the tank Note Do not over tighten plastic connections Step 17 Step 18 Note Set the blue ball valve knob in line...

Страница 12: ...be used for drinking Open the RO faucet and leave it open until water begins to trickle out this may take a few minutes and the water will come out slowly Step 4 Turn on the incoming cold water at the...

Страница 13: ...would be replaced during a semiannual or annual filter change However if at any time you notice a reduction in water production or an unpleasant taste in the reverse osmosis water it could be time to...

Страница 14: ...ur face Using a dosing syringe see figure slowly insert 1 teaspoon 5 mL of common household bleach into the tube WARNING Do not use needle syringe DANGER IF BLEACH GETS IN EYES Hold eye open and rinse...

Страница 15: ...tank Once the storage tank is empty remove all filter cartridges order not important place them into a sealed plastic bag and store in your refrigerator NOTICE DO NOT FREEZE To Restart System Step 1...

Страница 16: ...y storage tank of water Set tank air pressure between 5 7 psi See previous page Low Pressure in Tank Use a Digital Air Gauge for best results The empty tank pressure should be 5 7 psi See page 14 4 Wa...

Страница 17: ...Cysts 92 000 ml 3 ml 99 99 7 44 50psi 18 minimum 50 000 mL N A Fluoride Reduction 8 7 0 19 97 0 7 24 50psi 0 3 8 0 10 1 5 Lead Reduction 0 15 0 002 98 8 7 39 50psi 0 005 0 15 10 0 0107 Perchlorate 130...

Страница 18: ...ONITRILE 98 0 024 0 0006 DICHLOROACETONITRILE 98 0 0096 0 0002 TRICHLOROACETONITRILE 98 0 015 0 0003 HALOKETONES HK 1 1 DICHLORO 2 PROPANONE 99 0 0072 0 0001 1 1 1 TRICHLORO 2 PROPANONE 96 0 0082 0 00...

Страница 19: ...onvert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water utility contact the utility to find out if free chlorine or combined chlorine is used in the water...

Страница 20: ...Page 20 This page intentionally left blank...

Страница 21: ...Purchase __________ Date of Install ___________ Installed by _____________ NOTES Date Sediment Filter 6 months Membrane 2 5 years Carbon Pre Filter 6 months VOC Post Filter 12months Model Number _____...

Страница 22: ...exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is micro biologically unsafe or of unknown quality without adequate disinfe...