Page 15

  
 
 
 
  

 

 

 

 
 
 

 
 

 

Check Air Pressure in the Tank

NOTICE

    

Check air pressure only when tank is empty of water!

Check air pressure in the storage tank when you notice a decrease in available water from the RO sys

-

tem. Air can be added with a bicycle pump using the schrader valve that is located on the lower side of 

the tank behind the blue plastic cap.

Step 1: 

 Turn off the incoming water supply to the RO.

Step 2: 

 Open the RO Faucet and allow water to drain from the tank 

until it is completely empty.

TIP:    

 When water from the RO faucet slows to a trickle, with the 
faucet still in the open  position, you may add air to the 
tank to purge any left over water, this will ensure that the 
tank is completely empty. 

Step 3: 

 Once all water in the tank is purged, check air pressure using an air pressure gauge, it 

should read between 5 - 7 PSI. (Digital air pressure gauge is recommended)

Step 4: 

Follow startup procedure on page 12.

Procedure for Extended Non-Use (More than 2 months)

Turn off the water supply to your RO system at the adapt-a-valve and open the RO faucet to drain the 

storage tank.  Once the storage tank is empty, remove all filter cartridges (order not important), place 

them into a sealed plastic bag and store in your refrigerator. 

NOTICE

  

DO NOT FREEZE

To Restart System:

Step 1: 

  Reinstall all filters on to the RO unit. Filters are color coded to match the filter heads they 

snap in to.  Refer to page 13 step three for cartridge installation procedure.

Step 2:  

  Turn on water supply to the system at the Adapt-a-Valve.  (Check frequently over the next 

24 hours to ensure no leaks are present).

NOTICE

    If you have connected your RO system to a refrigerator / ice maker, make sure the 

ice maker is off (do not allow water to flow to the ice maker) until the tank has been 

allowed to completely fill. 

Step 3: 

  Open the RO faucet and leave it open until water begins to trickle out (it will come out 

slowly).

Step 4: 

  Close the RO faucet allowing the storage tank to fill with water.  It may take 3 to 6 hours 

to fill the tank completely depending on the production capability of the membrane, local 

water temperature and water pressure. 

Step 5: 

  After the Tank has filled, open the RO Faucet to flush the tank completely. You will know 

that the tank is empty when the flow rate from the RO faucet is down to a trickle.  The 

second tank can be used for drinking. 

Содержание RO-PURE Plus

Страница 1: ...r failure to follow any attached instructions or operating parameters may lead to the product s failure Model RO PURE Plus System Tested and certified by WQA against NSF ANSI Standard 58 for the reduc...

Страница 2: ...nge 6 months The second stage contains a 5 micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane recommended...

Страница 3: ...ion 9 Drain Saddle Tube Connection 9 Blue Tube Connection 10 Red Tube Connection 10 Green Tube Connection 11 Reverse Osmosis Module Mounting 11 Tank Ball Valve Installation 11 Blue Tube Connection Fro...

Страница 4: ...aximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5 NTU Hardness Maximum 10 Grains Per Gallon Hardness Recommended hardness not to exceed 10 grains per gallon or 1...

Страница 5: ...LUE TUBING WITH 90 BEND 4FT 11 400048 3 8 BLACK TUBING 3FT X 1 12 142002 1 4 RED TUBING WITH 90 BEND 4FT 13 105311 SEDIMENT PRE FILTER RED 14 105351 CARBON PRE FILTER YELLOW 15 105331 REVERSE OSMOSIS...

Страница 6: ...hen drilling Watts accepts no responsibility for damage resulting from the installation of faucet Diamond tip bit recommended Marble Counter top We recommend contacting a qualified contractor for dril...

Страница 7: ...e lubricant if needed Assemble Faucet Figure C 7 Align the release button on the back of the upper faucet assembly approximately 45 left off the back of the lower faucet assembly 8 Press the upper fau...

Страница 8: ...pter no washer 1 Brass Adapter with black washer 1 White rubber washer Make sure that the black collet is installed in to the 1 4 opening on the Adapt a valve Don t forget to install the white compres...

Страница 9: ...second drain Installation of the drain saddle near a garbage disposal may cause the drain line to plug If no other installation of drain line is available Premier offers drain line installation kit pa...

Страница 10: ...E THE FLOW RESTRICTOR OR CUT THE RED TUBING AS IT WILL DAMAGE THE FLOW RESTRICTOR Blue Tube Connection From FAUCET To The RO Module Locate the 1 4 BLUE tube from the RO faucet Insert the open end of t...

Страница 11: ...uick connect ball valve supplied in the parts bag onto the stainless steel connector on the tank Note Do not over tighten plastic connections Step 17 Step 18 Note Set the blue ball valve knob in line...

Страница 12: ...be used for drinking Open the RO faucet and leave it open until water begins to trickle out this may take a few minutes and the water will come out slowly Step 4 Turn on the incoming cold water at the...

Страница 13: ...would be replaced during a semiannual or annual filter change However if at any time you notice a reduction in water production or an unpleasant taste in the reverse osmosis water it could be time to...

Страница 14: ...ur face Using a dosing syringe see figure slowly insert 1 teaspoon 5 mL of common household bleach into the tube WARNING Do not use needle syringe DANGER IF BLEACH GETS IN EYES Hold eye open and rinse...

Страница 15: ...tank Once the storage tank is empty remove all filter cartridges order not important place them into a sealed plastic bag and store in your refrigerator NOTICE DO NOT FREEZE To Restart System Step 1...

Страница 16: ...y storage tank of water Set tank air pressure between 5 7 psi See previous page Low Pressure in Tank Use a Digital Air Gauge for best results The empty tank pressure should be 5 7 psi See page 14 4 Wa...

Страница 17: ...Cysts 92 000 ml 3 ml 99 99 7 44 50psi 18 minimum 50 000 mL N A Fluoride Reduction 8 7 0 19 97 0 7 24 50psi 0 3 8 0 10 1 5 Lead Reduction 0 15 0 002 98 8 7 39 50psi 0 005 0 15 10 0 0107 Perchlorate 130...

Страница 18: ...ONITRILE 98 0 024 0 0006 DICHLOROACETONITRILE 98 0 0096 0 0002 TRICHLOROACETONITRILE 98 0 015 0 0003 HALOKETONES HK 1 1 DICHLORO 2 PROPANONE 99 0 0072 0 0001 1 1 1 TRICHLORO 2 PROPANONE 96 0 0082 0 00...

Страница 19: ...onvert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water utility contact the utility to find out if free chlorine or combined chlorine is used in the water...

Страница 20: ...Page 20 This page intentionally left blank...

Страница 21: ...Purchase __________ Date of Install ___________ Installed by _____________ NOTES Date Sediment Filter 6 months Membrane 2 5 years Carbon Pre Filter 6 months VOC Post Filter 12months Model Number _____...

Страница 22: ...exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is micro biologically unsafe or of unknown quality without adequate disinfe...

Отзывы: