background image

Page 13

  
 
 
 
  

 

 

 

 
 
 

 
 

 

Place a towel under the RO module to catch any excess water that 

may drip out from the filters during the changeover.

Step  1     

Your RO module is equipped with valve heads which will automatically turn off the water supply to each 

filter when the filter is released, thus you do not need to turn off the incoming water supply at the Adapt-

a-Valve. The RO faucet must be off when filters are replaced. To make the removal of the filter cartridges 

easier, the heads & cartridges may be swiveled up to 90 degrees as shown in the pictures below.

Step  2    

To  install  a  filter  cartridge:

 Remove the seal cap and insert 

the  cartridge  into  the  valve  head  until  you  hear  an  audible  “click” 

(the  button  does  not  need  to  be  pressed  to  install  new  filters).    

Step 3   

To remove a filter cartridge:

 Push & hold the button on the 

valve head above the filter. Pull cartridge downward (from the 

head) to remove. Release button and discard old filter.  

Changing The Filter Cartridges

Membrane Replacement (2 - 5 Years)

√ 

One Membrane    

(50 GPD Green Label P/N: 105331)

Replace: 

 

Membranes have a life expectancy between 2 and 5 years, depending on the incoming water conditions and the 

amount the RO system is used. This reverse osmosis membrane is critical for effective reduction of total dissolved solids 

(TDS). The product water should be tested periodically to verify that the system is performing satisfactorily.

 

Normally, a membrane would be replaced during a semiannual or annual filter change.  However, if at any time you  

notice a reduction in water production or an unpleasant taste in the reverse osmosis water, it could be time to replace the 

membrane. Premier recommends replacing the membrane when TDS reduction falls below 75%.

 

A water sample may be sent to Premier for a free diagnosis of your membranes performance.  To send a water 

sample, use 2 clean containers and fill 1/2 cup of tap water in one container and 1/2 cup of RO water in 2nd container. Clearly 

label each sample. Send the samples to the address listed on the cover of this manual attention “Water Samples”. Premier 

will test the water and mail or call you with the results.

You must reset the faucet monitor. Follow procedure on page 8.

Note:

This reverse osmosis system contains a replaceable component (the RO membrane) which is critical to the 

efficiency  of  the  system.  Replacement  of  this  reverse  osmosis  membrane  should  be  with  one  of  identical 

specifications  as  defined  by  Premier  to  assure  the  same  efficiency  and  contaminant  reduction  performance.

Annual Maintenance

 

-(

Sanitization Recommended See PG.15

)

√ 

One sediment filter  

(Red Label P/N: 105311)

√ 

One carbon pre-filter  

(Yellow Label P/N: 105351)

 One carbon VOC-filter   (Silver Label P/N: 105381) 

Replace:

√ 

One sediment filter  

(Red Label P/N: 105311)

√ 

One carbon pre-filter  

(Yellow Label P/N: 105351)

Replace:

6 Month System Maintenance

Tip:

This is a good time to check the air pressure in your storage 

tank. For instructions please see page 14.
Flush first tank full after completing the annual maintenance.

Note:

PULL

PRESS

Содержание RO-PURE Plus

Страница 1: ...r failure to follow any attached instructions or operating parameters may lead to the product s failure Model RO PURE Plus System Tested and certified by WQA against NSF ANSI Standard 58 for the reduc...

Страница 2: ...nge 6 months The second stage contains a 5 micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane recommended...

Страница 3: ...ion 9 Drain Saddle Tube Connection 9 Blue Tube Connection 10 Red Tube Connection 10 Green Tube Connection 11 Reverse Osmosis Module Mounting 11 Tank Ball Valve Installation 11 Blue Tube Connection Fro...

Страница 4: ...aximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5 NTU Hardness Maximum 10 Grains Per Gallon Hardness Recommended hardness not to exceed 10 grains per gallon or 1...

Страница 5: ...LUE TUBING WITH 90 BEND 4FT 11 400048 3 8 BLACK TUBING 3FT X 1 12 142002 1 4 RED TUBING WITH 90 BEND 4FT 13 105311 SEDIMENT PRE FILTER RED 14 105351 CARBON PRE FILTER YELLOW 15 105331 REVERSE OSMOSIS...

Страница 6: ...hen drilling Watts accepts no responsibility for damage resulting from the installation of faucet Diamond tip bit recommended Marble Counter top We recommend contacting a qualified contractor for dril...

Страница 7: ...e lubricant if needed Assemble Faucet Figure C 7 Align the release button on the back of the upper faucet assembly approximately 45 left off the back of the lower faucet assembly 8 Press the upper fau...

Страница 8: ...pter no washer 1 Brass Adapter with black washer 1 White rubber washer Make sure that the black collet is installed in to the 1 4 opening on the Adapt a valve Don t forget to install the white compres...

Страница 9: ...second drain Installation of the drain saddle near a garbage disposal may cause the drain line to plug If no other installation of drain line is available Premier offers drain line installation kit pa...

Страница 10: ...E THE FLOW RESTRICTOR OR CUT THE RED TUBING AS IT WILL DAMAGE THE FLOW RESTRICTOR Blue Tube Connection From FAUCET To The RO Module Locate the 1 4 BLUE tube from the RO faucet Insert the open end of t...

Страница 11: ...uick connect ball valve supplied in the parts bag onto the stainless steel connector on the tank Note Do not over tighten plastic connections Step 17 Step 18 Note Set the blue ball valve knob in line...

Страница 12: ...be used for drinking Open the RO faucet and leave it open until water begins to trickle out this may take a few minutes and the water will come out slowly Step 4 Turn on the incoming cold water at the...

Страница 13: ...would be replaced during a semiannual or annual filter change However if at any time you notice a reduction in water production or an unpleasant taste in the reverse osmosis water it could be time to...

Страница 14: ...ur face Using a dosing syringe see figure slowly insert 1 teaspoon 5 mL of common household bleach into the tube WARNING Do not use needle syringe DANGER IF BLEACH GETS IN EYES Hold eye open and rinse...

Страница 15: ...tank Once the storage tank is empty remove all filter cartridges order not important place them into a sealed plastic bag and store in your refrigerator NOTICE DO NOT FREEZE To Restart System Step 1...

Страница 16: ...y storage tank of water Set tank air pressure between 5 7 psi See previous page Low Pressure in Tank Use a Digital Air Gauge for best results The empty tank pressure should be 5 7 psi See page 14 4 Wa...

Страница 17: ...Cysts 92 000 ml 3 ml 99 99 7 44 50psi 18 minimum 50 000 mL N A Fluoride Reduction 8 7 0 19 97 0 7 24 50psi 0 3 8 0 10 1 5 Lead Reduction 0 15 0 002 98 8 7 39 50psi 0 005 0 15 10 0 0107 Perchlorate 130...

Страница 18: ...ONITRILE 98 0 024 0 0006 DICHLOROACETONITRILE 98 0 0096 0 0002 TRICHLOROACETONITRILE 98 0 015 0 0003 HALOKETONES HK 1 1 DICHLORO 2 PROPANONE 99 0 0072 0 0001 1 1 1 TRICHLORO 2 PROPANONE 96 0 0082 0 00...

Страница 19: ...onvert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water utility contact the utility to find out if free chlorine or combined chlorine is used in the water...

Страница 20: ...Page 20 This page intentionally left blank...

Страница 21: ...Purchase __________ Date of Install ___________ Installed by _____________ NOTES Date Sediment Filter 6 months Membrane 2 5 years Carbon Pre Filter 6 months VOC Post Filter 12months Model Number _____...

Страница 22: ...exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is micro biologically unsafe or of unknown quality without adequate disinfe...

Отзывы: