background image

Page 17

  
 
 
 
  

 

 

 

 
 
 

 
 

 

Watts Premier

 8716 W Ludlow Drive Suite #1

Peoria, AZ 85381

RO-Pure PLUS

  System conforms to NSF Standard 58 for specific claims.

RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVALS:
Note:  Depending on incoming feed water conditions replacement time frame may vary.

Description    Change 

time 

Frame 

Sediment Pre-filter:   

#105311   

6 Months   

 

Carbon Pre-filter: 

 

#105351   

6 Months 

VOC Carbon filter   

#105381   

12 Months  

 

50 GPD R.O. Membrane: 

#105331   

2 to 5 years 

 

This system has been tested according to NSF/ANSI 58 for reduction of the substances listed below.  The concentration of the indicated substances in water 

entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI 58.  This 

system has been tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or arsenate) at concentrations of 0.30 mg/L or 

less.   This system reduces pentavalent arsenic, but may not remove other forms of arsenic.  This system is to be used on water supplies containing a detectable free 
chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic.  Treatment with chloramine (combined 

chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic,  Please see the Arsenic Facts section of the Performance Data 

Sheet for further information.

 

Avg. In. 

Avg. Eff. 

% Reduction  pH 

Pressure 

Max Eff. 

Inf. challenge 

Max Allowable

 

(mg/L) 

(mg/L)     mg/L 

concentration 

concentration

 

 

 

   

 

mg/L 

mg/L

Arsenic (Pentavalent) 

.310 

0.001 

99.6% 

7.24 

50psi 

0.002 

   0.30±10% 

   0.010 mg/L

Barium Reduction 

9.2 

0.08 

99.0% 

7.64 

50psi 

0.12 

   10.0±10% 

    2.0

Cadmium Reduction 

0.031 

0.0004 

98.0% 

7.49 

50psi 

0.0008 

    0.03±10% 

    0005

Chromium (Hexavalent) 

0.30 

0.002 

99.0% 

7.24 

50psi 

0.004 

    0.03±10% 

    0.1

Chromium (Trivalent) 

0.30 

0.001 

99.0% 

7.64 

50psi 

0.002 

    0.03±10% 

    0.1

Copper Reduction 

3.2 

0.02 

99.0% 

7.40 

50psi 

0.04 

    3.0±10% 

    1.3

Cysts 

92,000#/ml 

3 #/ml 

99.99% 

7.44 

50psi 

18      minimum 50,000/mL 

     N/A 

Fluoride Reduction 

8.7 

0.19 

97.0% 

7.24 

50psi

 

0.3 

    8.0±10% 

    1.5    

Lead Reduction 

0.15 

0.002 

98.8% 

7.39 

50psi 

0.005 

    0.15±10% 

    0.0107

Perchlorate 

130 

2.8 

97.9%

Radium 226/228 

25pCi/L 

5pCi/L 

80.0% 

7.24 

50psi 

5pCi/L 

    25pCiL±10% 

    5pCiL

Selenium 

94.85 

<0.2 

97.0% 

7.24 

50psi 

<0.2 

    0.10±10% 

    0.05

TDS 

770 

35 

95.0% 

7.28 

50psi 

26.0 

    750±40mg/L 

    187

Turbidity 

11.3 

0.1 

99.0% 

7.43 

50psi 

0-1 

    11±1mg/L 

    0.5NTU

 

Recovery - 22% 

 

 Daily Production Rate - 20.5 GPD 

 

Efficiency - 10.5%

Depending on water chemistry, water temperature, and water pressure Premier’s R.O. Systems production and performance will vary.

Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under

operating conditions that approximate typical daily usage. Recovery rating means the percentage of the influent water to the membrane portion 

of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the 

storage tank is bypassed. There is an average of 4 gallons of reject water for every 1 gallon of product water produced.

REFER TO OWNER’S INSTALLATION/SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY 

INFORMATION.

Phone: (480) 675-7995                                  Fax:  (623) 866-5666                                     www.PremierH2o.com

GENERAL USE CONDITIONS:

1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality.  DO NOT use with water that 

is microbiologically unsafe or unknown quality without adequate disinfection before and after the system.  Systems certified for cyst reduction may be used on 

disinfected water that may contain filterable cysts.

2. Operating Temperature: 

 

 

Maximum: 100°F (40.5°C) 

 

 

Minimum: 40° (4.4°)

3. Operating Water Pressure: 

 

 

Maximum: 85 psi (6.0kg/cm2)   

 

Minimum: 40 psi (2.8kg/cm2)

4. pH 

 

 

 

 

2 to 11

5. Maximum Iron present in incoming water supply must be less than 0.2 ppm.

6. Hardness of more than 10 grains per gallon (170 ppm) may reduce RO membrane life expectancy.

7. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.

TECHNICAL & WARRANTY INFORMATION

Содержание RO-PURE Plus

Страница 1: ...r failure to follow any attached instructions or operating parameters may lead to the product s failure Model RO PURE Plus System Tested and certified by WQA against NSF ANSI Standard 58 for the reduc...

Страница 2: ...nge 6 months The second stage contains a 5 micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane recommended...

Страница 3: ...ion 9 Drain Saddle Tube Connection 9 Blue Tube Connection 10 Red Tube Connection 10 Green Tube Connection 11 Reverse Osmosis Module Mounting 11 Tank Ball Valve Installation 11 Blue Tube Connection Fro...

Страница 4: ...aximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5 NTU Hardness Maximum 10 Grains Per Gallon Hardness Recommended hardness not to exceed 10 grains per gallon or 1...

Страница 5: ...LUE TUBING WITH 90 BEND 4FT 11 400048 3 8 BLACK TUBING 3FT X 1 12 142002 1 4 RED TUBING WITH 90 BEND 4FT 13 105311 SEDIMENT PRE FILTER RED 14 105351 CARBON PRE FILTER YELLOW 15 105331 REVERSE OSMOSIS...

Страница 6: ...hen drilling Watts accepts no responsibility for damage resulting from the installation of faucet Diamond tip bit recommended Marble Counter top We recommend contacting a qualified contractor for dril...

Страница 7: ...e lubricant if needed Assemble Faucet Figure C 7 Align the release button on the back of the upper faucet assembly approximately 45 left off the back of the lower faucet assembly 8 Press the upper fau...

Страница 8: ...pter no washer 1 Brass Adapter with black washer 1 White rubber washer Make sure that the black collet is installed in to the 1 4 opening on the Adapt a valve Don t forget to install the white compres...

Страница 9: ...second drain Installation of the drain saddle near a garbage disposal may cause the drain line to plug If no other installation of drain line is available Premier offers drain line installation kit pa...

Страница 10: ...E THE FLOW RESTRICTOR OR CUT THE RED TUBING AS IT WILL DAMAGE THE FLOW RESTRICTOR Blue Tube Connection From FAUCET To The RO Module Locate the 1 4 BLUE tube from the RO faucet Insert the open end of t...

Страница 11: ...uick connect ball valve supplied in the parts bag onto the stainless steel connector on the tank Note Do not over tighten plastic connections Step 17 Step 18 Note Set the blue ball valve knob in line...

Страница 12: ...be used for drinking Open the RO faucet and leave it open until water begins to trickle out this may take a few minutes and the water will come out slowly Step 4 Turn on the incoming cold water at the...

Страница 13: ...would be replaced during a semiannual or annual filter change However if at any time you notice a reduction in water production or an unpleasant taste in the reverse osmosis water it could be time to...

Страница 14: ...ur face Using a dosing syringe see figure slowly insert 1 teaspoon 5 mL of common household bleach into the tube WARNING Do not use needle syringe DANGER IF BLEACH GETS IN EYES Hold eye open and rinse...

Страница 15: ...tank Once the storage tank is empty remove all filter cartridges order not important place them into a sealed plastic bag and store in your refrigerator NOTICE DO NOT FREEZE To Restart System Step 1...

Страница 16: ...y storage tank of water Set tank air pressure between 5 7 psi See previous page Low Pressure in Tank Use a Digital Air Gauge for best results The empty tank pressure should be 5 7 psi See page 14 4 Wa...

Страница 17: ...Cysts 92 000 ml 3 ml 99 99 7 44 50psi 18 minimum 50 000 mL N A Fluoride Reduction 8 7 0 19 97 0 7 24 50psi 0 3 8 0 10 1 5 Lead Reduction 0 15 0 002 98 8 7 39 50psi 0 005 0 15 10 0 0107 Perchlorate 130...

Страница 18: ...ONITRILE 98 0 024 0 0006 DICHLOROACETONITRILE 98 0 0096 0 0002 TRICHLOROACETONITRILE 98 0 015 0 0003 HALOKETONES HK 1 1 DICHLORO 2 PROPANONE 99 0 0072 0 0001 1 1 1 TRICHLORO 2 PROPANONE 96 0 0082 0 00...

Страница 19: ...onvert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water utility contact the utility to find out if free chlorine or combined chlorine is used in the water...

Страница 20: ...Page 20 This page intentionally left blank...

Страница 21: ...Purchase __________ Date of Install ___________ Installed by _____________ NOTES Date Sediment Filter 6 months Membrane 2 5 years Carbon Pre Filter 6 months VOC Post Filter 12months Model Number _____...

Страница 22: ...exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is micro biologically unsafe or of unknown quality without adequate disinfe...

Отзывы: