14.2
First-time start-up defaults
The pump is preset with operational parameters as shown in table below.
Parameter
630 default
Language
Not set
Default mode
Manual
Default manual speed
165 rpm
Pump status
Stopped
Max speed
265 rpm
Direction
CW
Pumphead
620R
Tube size
15.9 mm
Tube material
Bioprene
Flow calibration
0.061 l/rev
Flow units
rpm
SG value
1
Keypad lock
Disabled
Auto-restart
OFF
Analog signal type
mA
Analog scaling type
mA
Analog min current
5 mA
Analog max current
19 mA
Analog min flow rate/rpm
0 rpm
Analog max flow rate/rpm
265 rpm
Beeper
ON
Security code
Not set
MemoDose flow rate
Mid flow rate of chosen pumphead
MemoDose volume
100 ml
Pump number baud rate
9600
Stop bits
2
Remote start/stop input
High = stop
Leak detector input
High = leak
Input 4
Disabled
Input 5
Disabled
Output 1
Run/stop
Output 1 - status
High = run
Output 2
Direction
46
m-630dun-en-08.2