Line
Function
Setting range
or display
Setting range
or display
Basic
setting
Heating / Cooling time program, circuit 1
500
Pre-selection (Day / Week)
Mon-Sun, Mon-Fri, Sat-Sun,
Monday, Tuesday, …
Mon-Sun
501
1st phase On (start)
00:00 --:--
10 min
6:00
502
1st phase Off (end)
00:00 --:--
10 min
22:00
503
2nd phase On (start)
00:00 --:--
10 min
--:--
504
2nd phase Off (end)
00:00 --:--
10 min
--:--
505
3rd phase On (start)
00:00 --:--
10 min
--:--
506
3rd phase Off (end)
00:00 --:--
10 min
--:--
515
Copy
516
Standard values, Circuit 1
No, Yes
No
Yes + OK: The standard values memorised in the regulator replace and cancel the customised heating programs. Your
customised settings are therefore lost
Time program 4 / DHW
If the installation is fitted with the DHW kit.
560
Pre-selection (Day / Week)
Mon-Sun, Mon-Fri, Sat-Sun,
Monday, Tuesday, …
Mon-Sun
561
1st phase On (start)
00:00 --:--
10 min
00:00
562
1st phase Off (end)
00:00 --:--
10 min
05:00
563
2nd phase On (start)
00:00 --:--
10 min
14:30
564
2nd phase Off (end)
00:00 --:--
10 min
17:00
565
3rd phase On (start)
00:00 --:--
10 min
--:--
566
3rd phase Off (end)
00:00 --:--
10 min
--:--
575
Copy
576
Standard values
No, Yes
No
Yes + OK: The standard values memorised in the regulator replace and cancel the customised heating programs. Your
customised settings are therefore lost
Holidays, heating circuit 1
(For the Holiday program is active, the heating mode should be on AUTO)
641
Preselection
Period 1 to 8
Period 1
642
Date holidays start (Day / Month)
01 01 31 12
1
643
Date holidays end (Day / Month)
01 01 31 12
1
648
Heating schedule during the holidays
Frost protection, Reduced
Frost
protection
Heating adjustment, circuit 1
710
Comfort ambient temperature setpoint
Reduced setpoint…
Comfort setpoint max
0,5 °C
20 °C
712
Reduced ambient temperature setpoint
Frost-free temp…
Comfort temperature
0,5 °C
19 °C
714
Frost-free ambient temperature setpoint
4 °C… Reduced temperature
0,5 °C
8 °C
Cooling circuit 1
901
Operating mode
Off, Automatic
Off
902
Comfort cooling setpoint
17 40 °C
0,5 °C
24 °C
903
Reduced cooling setpoint
17 40 °C
0,5 °C
26 °C
Operation manual "1780 - EN"
- 13 -