background image

Line

Function

Setting range  

or display

Setting range  

or display

Basic  

setting

DHW setting 

(domestic hot water)

If the installation is fitted with the DHW kit.

1610

Comfort setting

Reduced setting (line 1612)… 

65 °C

1

55 °C

The backup electrical system is required to reach this level 

1612

Reduced setting

8 °C    

Comfort setting (line 1610)

1

40 °C

Energy meter

3121

Heat delivered heating 1

--

3122

Heat delivered DHW 1

--

3123

Cooling delivered cooling 1

--

3124

Not used

--

3125

Not used

--

3126

Not used

--

3128

Heat delivered heating 2

--

3129

Heat delivered DHW 2

--

3130

Cooling delivered cooling 2

--

3131

Not used

--

3132

Not used

--

3133

Not used

--

3135

Heat delivered heating 3

--

3136

Heat delivered DHW 3

--

3137

Cooling delivered cooling 3

--

3138

Not used

--

3139

Not used

--

3140

Not used

--

3142

Heat delivered heating 4

--

3143

Heat delivered DHW 4

--

3144

Cooling delivered cooling 4

--

3145

Not used

--

3146

Not used

--

3147

Not used

--

3149

Heat delivered heating 5

--

3150

Heat delivered DHW 5

--

3151

Cooling delivered cooling 5

--

3152

Not used

--

3153

Not used

--

3154

Not used

--

3156

Heat delivered heating 6

--

3157

Heat delivered DHW 6

--

3158

Cooling delivered cooling 6

--

3159

Not used

--

3160

Not used

--

Operation manual "1780 - EN"

Hydraulic indoor unit

- 14 -

Содержание WSYP100DG6

Страница 1: ...40549 D sseldorf Germany Subject to modifications without notice Non contractual document WSYP100DG6 Heat pump air water split system hydraulicindoorunit Fujitsu General Euro GmbH Werftstrasse 20 4054...

Страница 2: ...of the installation 5 Operation of the installation 6 User interface Room control unit option and Room thermostat option 6 Description of the display 8 Appliance start up 9 Quick start up 9 Setting th...

Страница 3: ...with your installer Do not climb on the top of the outdoor unit The room in which the appliance is operating must be correctly ventilated in order to prevent any loss of oxygen if there is an escape...

Страница 4: ...freely The great stability in a regulation system for floor heating systems avoids sharp differences in temperature However this stability involves a reaction time of the order of several hours approx...

Страница 5: ...ontrol unit Heat pumps are systems that can be connected to any form of low temperature heat distribution systems the heat captured by the heat pump can therefore be used in different ways Floor heati...

Страница 6: ...at option figure 2 C Auto Auto ESC OK 0 4 8 12 16 20 24 1 2 3 4 5 6 7 8 11 5 2 10 11 Room control unit T75 T78 Room thermostat T55 T58 1 2 3 4 5 6 7 8 9 User interface Operation manual 1780 EN Hydraul...

Страница 7: ...ng to the heating program Summer winter mode switchover is automatic Constant comfort temperature Constant reduced temperature Stand by mode with anti frost protection Provided that the heat pump s el...

Страница 8: ...r operation Default message Service Special operation INFO Information level activated PROG Program activated ECO ECO mode activated Heating temporarily stopped temperature ambiante Hour Parameter num...

Страница 9: ...t time Engage the start stop switch During the regulator initialisation phase the display shows all the symbols and then Data update and then State heat pump Select the AUTO heating mode figure 6 Sele...

Страница 10: ...to confirm Turn the knob Select line 1 Hours minutes Press OK to confirm The hour display flashes Turn the knob to set the time Press OK to confirm The minutes display flashes Turn the knob to set th...

Страница 11: ...ase on 2nd phase off 3rd phase on 3rd phase off Default values Copy Mon Sun Mon Fri Sat Sun Monday Tuesday Sunday Holidays heating circuit 1 Holidays heating circuit 2 Operation level Period 1 Period...

Страница 12: ...list Choose the desired menu Scroll the function lines Choose the desired line Adjust the parameter Check the setting by pressing OK To return the menu press ESC If no setting is made for 8 minutes t...

Страница 13: ...ase Off end 00 00 10 min 17 00 565 3rd phase On start 00 00 10 min 566 3rd phase Off end 00 00 10 min 575 Copy 576 Standard values No Yes No Yes OK The standard values memorised in the regulator repla...

Страница 14: ...eat delivered heating 2 3129 Heat delivered DHW 2 3130 Cooling delivered cooling 2 3131 Not used 3132 Not used 3133 Not used 3135 Heat delivered heating 3 3136 Heat delivered DHW 3 3137 Cooling delive...

Страница 15: ...d DHW 10 3186 Cooling delivered cooling 10 3187 Not used 3188 Not used 3189 Not used Error 6711 Heat pump Reset No Yes No Maintenance special regime 7141 Emergency regime Off On Off Off Heat pump func...

Страница 16: ...heat pump is operating electrical power failure or unprogrammed pressing of the on off switch on the hydraulic unit the display will show error 370 when the appliance restarts Do not be concerned the...

Страница 17: ...rs on PROG mode or AUTO mode for piloting by the regulation board The difference between the comfort temperature and the reduced temperature is from 3 5 C Frost protection temperature is set directly...

Страница 18: ...nstaller If frequent refills are required it is essential that you look for any leaks The frequent water supply is at risk of scaling for the Heat exchanger and degrades performance and longevity of i...

Страница 19: ...Operation manual 1780 EN 19 Hydraulic indoor unit...

Страница 20: ...as this could have harmful effects on your health and on the environment The dismantling and treatment of refrigerant oil and other parts must be done by a qualified installer in accordance with relev...

Отзывы: