Scope of application
This heat pump provides :
- Heating in winter.
- Control of two heating circuits*.
- Production of domestic hot water*
(provided that combined with a DHW tank).
- Cooling* in summer (for floor heating-cooling system
or fan-convectors).
- Installation with boiler connection* as a supplementary
heating for the coldest days.
- Heating the swimming pool*.
*
: These options require the use of additional kits
(see para. "Optional equipment").
Installation and operating manual "1364 - EN"
Split system (3-phase)
- 4 -
Optional equipment
• 2nd circuit kit (UTW-KZS*A).
- for connecting 2 heating circuits.
• DHW kit (UTW-KDW*A).
- for connecting a DHW tank (with built-in electrical
backups).
• Boiler connection kit (UTW-KBS*A).
-for connecting a boiler to the heat pump.
• Room thermostat (UTW-C55*A).
- for correcting the ambient temperature.
• Room control unit (UTW-C75*A).
- for correcting the ambient temperature and
programming the heat pump.
• Cooling kit (UTW-KCL*A).
• Swimming pool kit (UTW-KSP*A).
• High flow rate circulating pump kit (UTW-PHF*A).
- for the installation of 1 circuit floor heating.
• Cooling kit (UTW-KCH*A) compatible with high flow
rate circulating pump.
Packing list
Heat pump
Outdoor unit
Hydraulic module
112
WO*K112LCT
WS*K160DA9
140
WO*K140LCT
160
WO*K160LCT