2 4 Installation of the outdoor unit
2 4 1 Installation precautions
"
The outdoor unit must only be installed outside
(outdoors). If a shelter is required, it must have
broad openings on the 4 walls and observe the
installation clearances (
figure 11
).
• Choose a site that is preferably sunny and sheltered
from strong cold predominant winds (mistral,
tramontana, etc…).
• The unit must be easily accessible for future installation
and maintenance work.
• Ensure that it is possible to make the connections to
the hydraulic unit easily.
• The outdoor unit is able to withstand bad weather but
avoid installing in a position where it is likely to be
exposed to significant dirt or flowing water (under a
defective gutter for example).
• Water may drain away from the outdoor unit when it
is operating. Do not install the appliance on a paved
terrace ; choose a well-drained place (e.g. gravel
or sand). If the installation is in an area where the
temperature can be lower than 0°C for a long period,
check that the presence of ice does not present any
danger. A drainage pipe can also be connected to the
outdoor unit (see
figure 12, page 14
).
• Nothing should obstruct the air circulation through the
evaporator and from the fan.
• Keep the outdoor unit away from heat sources and
inflammable products.
• Make sure the appliance not disturb the surrounding
area or users (noise level, draught generated, low
1000 mm
ou plus
200 mm
300 mm
200 mm
1000 mm ou plus
150 mm
150 mm
300 mm
Max. 500 mm
1000 mm
1500 mm
250 mm
250 mm
500 mm
Max. 500 mm
1500 mm ou plus
300 mm
500 mm
1500 mm ou plus
1500 mm
500 mm
Max. 300 mm
1500 mm
Figure 11 - Minimum installation clearances around outdoor unit
or more
or more
or more
or more
Installation and operating manual "1364 - EN"
- 13 -
Split system (3-phase)