Line
Function
Setting range
or display
Setting
increment
Basic
setting
Time program 5 / Cooling
If the installation is fitted with the cooling kit (Only with the cooling kit option).
600
U
Pre-selection (Day / Week)
Mon-Sun, Mon-Fri, Sat-Sun,
Monday, Tuesday, …
Mon-Sun
601
U
1st phase On (start)
00:00... --:--
10 min
8:00
602
U
1st phase Off (end)
00:00... --:--
10 min
20:00
603
U
2nd phase On (start)
00:00... --:--
10 min
--:--
604
U
2nd phase Off (end)
00:00... --:--
10 min
--:--
605
U
3rd phase On (start)
00:00... --:--
10 min
--:--
606
U
3rd phase Off (end)
00:00... --:--
10 min
--:--
615
U
Copy
616
U
Default values
No, Yes
No
Yes + OK: The default values memorised in the regulator replace and cancel the customised heating programs. Your
customised settings are therefore lost.
Holidays, heating circuit 1
(For the Holiday program is active, the heating mode should be on AUTO).
641
U
Preselection
Period 1 to 8
Period 1
642
U
Period Start (Day / Month)
01 01 31 12
1
643
U
Period End (Day / Month)
01 01 31 12
1
648
U
Operating level
Frost protection, Reduced
Frost
protection
Holidays, heating circuit 2
(For the Holiday program is active, the heating mode should be on AUTO).
If the installation consists of 2 heating circuits (Only with the 2nd circuit kit option).
651
U
Preselection
Period 1 to 8
Period 1
652
U
Period Start (Day / Month)
01 01 31 12
1
653
U
Period End (Day / Month)
01 01 31 12
1
658
U
Operating level
Frost protection, Reduced
Frost
protection
Heating, circuit 1
710
U
Comfort setpoint
Reduced setpoint…
Comfort setpoint maximum
0,5 °C
20 °C
712
U
Reduced setpoint
Frost protection setpoint…
Comfort setpoint
0,5 °C
19 °C
714
U
Frost protection setpoint
4 °C… Reduced setpoint
0,5 °C
8 °C
716
S
Comfort setpoint maximum
20 °C 35 °C
1 °C
28 °C
720
I
Heating curve slope (
0,1... 4
0,02
0,5
721
I
Heating curve displacement (
-4,5 °C... 4,5 °C
0,5 °C
0
726
I
Heating curve adaption
Off, On
Off
Warning !
Not to modify, let on "Off".
730
I
Summer / Winter heating limits
8 °C 30 °C
0,5 °C
18 °C
When the average of the outside temperatures over the past 24 hours reaches 18°C, the regulator switches off the heating
(as an economy measure). During summer mode, the display shows "Eco". This function is only active in automatic mode.
732
S
24-hour heating limit
-10 °C... 10 °C
1 °C
-2 °C
This function enables you partially to offset the automatic summer / winter switchover during the intermediate seasons.
Increasing the value delays the switchover to summer regime.
Decreasing the value advances the switchover to summer regime.
This function is only active in automatic mode.
Installation and operating manual "1532 - EN"
Air to Water Heat Pump