2 Installation
2 1 Regulation installation
and maintenance conditions
The appliance must be installed and the maintained
by an approved professional in accordance with the
prevailing regulations and code of practice, in particular:
- The legislation on the handling of refrigerants.
- Heating installation with floor heating system.
- Low voltage electrical installations - Rules.
2 2 Unpacking and reservations
2 2 1 Receipt
Carefully check, in the carrier's presence, the general
appearance of the appliances and check that the
outdoor unit is not laid on its side or back.
In the case of any dispute, state any appropriate
reservations to the carrier in writing within 48 hours and
send a copy of this letter to the After-Sales service.
2 2 2 Handling
The outdoor unit should not be laid on its side or back
during transport.
If not kept upright during transport, the appliance could
be damaged through displacement of the refrigerant
and deformation of the compressor suspension.
Any damage caused by transportation of the unit lying
down is not covered by the warranty.
If necessary the outdoor unit may be tilted only during
manual handling (to go through a door or use a staircase).
This operation must be conducted very carefully and
the appliance must be immediately restored to upright
position.
2 2 3 Accessories provided
Accessories provided with the outdoor unit (
).
Accessories provided with the hydraulic unit (
2 3 Installation position
The choice of the position for installation is particularly
important insofar as any later movement is a delicate
operation requiring the intervention of a qualified person.
Choose the site of the outdoor unit and the hydraulic
unit after discussion with the customer.
Observe the maximum and minimum distances between
the hydraulic unit and the outdoor unit (
the guarantee of the performances and the system's
service life depend on this.
2 4 Installation of the outdoor unit
2 4 1 Installation precautions
"
The outdoor unit must only be installed outdoor
(outdoors). If a shelter is required, it must have
broad openings on the 4 walls and observe the
installation clearances (
).
• Choose a site that is preferably sunny and sheltered
from strong cold predominant winds (mistral,
tramontana, etc…).
• The unit must be easily accessible for future installation
and maintenance work (
).
• Ensure that it is possible to make the connections to
the hydraulic unit easily.
• The outdoor unit is able to withstand bad weather but
avoid installing in a position where it is likely to be
exposed to significant dirt or flowing water (under a
defective gutter for example).
• Water may drain away from the outdoor unit when it
is operating. Do not install the appliance on a paved
terrace; choose a well-drained place (e.g. gravel
or sand). If the installation is in an area where the
temperature can be lower than 0°C for a long period,
check that the presence of ice does not present any
danger. A drainage pipe can also be connected to the
outdoor unit (
).
1
3
2
4
1
Elbow
For draining away the
condensates
2
Plug (x 2)
3
Flexible insulation
plate
For filling the empty space
at the input to the
interconnection cable
figure 9 - Accessories provided with the outdoor unit
8
5
6
7
5
Bracket
To secure the hydraulic
model
6
Outdoor sensor
To monitor the outside
temp
7
Adaptater
1/2" - 5/8" and/or
1/4" - 3/8"
To connect the flared
connection and the
hydraulic unit
8
Nut 1/2"
and/or 1/4"
figure 10 - Accessories provided with the hydraulic unit
"
Model Comfort 10 only
Installation and operating manual "1532 - EN"
Air to Water Heat Pump
- 12 -