26
Troubleshooting Guide
SYMPTOM
PROBABLE CAUSE
CORRECTION
1. Fails to Regenerate
Automatically
Power supply plugged into
intermittent or dead power source
Connect to constant power source
Improper control valve
programming
Reset program settings
Defective power supply
Replace power supply
Defective Drive motor
Replace motor
2. Regeneration at
Wrong Time
Time of day improperly set, due to
power failure
Reset time of day programming and
install 9-volt battery.
Regeneration time set improperly
Reset regeneration time program-
ming
3. Poor Water Quality
Check items listed in #1 and #2
Bypass valve open
Close bypass valve.
Channeling
Check for too slow or high service
flow. Check for media fouling.
Lack of aeration in water
Program valve to draw air more
frequently
Increase number of minutes in air
draw cycle
Clean injection assembly and screen
4. Loss of Water
Pressure
Fouled media
Clean media. Pretreat to prevent.
Improper backwash setting
Backwash more frequently
5. Continuous Flow To
Drain
Foreign material in control
Call dealer. Clean valve and replace
pistons and seals.
Internal control leak
Same as above.
Valve jammed in backwash or rapid
rinse position
Same as above.
Motor stopped or jammed
Check for jammed piston. Replace
piston and seals. Replace motor if
motor is unresponsive.