Normal Operation

1. 

Home Display

 

a. Alternates between the display of Time of Day and Number of Days until the Next Backwash. 

 

 

- Days Remaining until the Next Backwash will count down from the entered value until it    

 

 

  reaches 1 day remaining.

 

 

- A Backwash Cycle will then be initiated at the next designated regeneration time.

2. 

Battery Back-Up

 (Uses a standard 9-volt alkaline battery.)

  

 

 

Features of Battery Back-Up:

 

 

• During power failures, the battery will maintain the time of day as long as the battery has    

 

 

  power. 

                             The display is turned off to conserve battery power during this time. To confirm that the    

 

 

  battery is working, press either button and the display will turn on for five (5) seconds.

 

 

• If power failure occurs while system is regenerating, the Isobar III valve will motor to a  

   

                              shut off position to prevent constant flow to drain. Depending upon system pressure and 

 

 

  other factors, it is possible to observe a reduced flow to drain during this step. After power                 

 

                is restored, the valve will return and finish the cycle where it left off prior to the power 

                              interruption.

   

 

 

• When used without battery back-up, during a power failure, the unit stops at its current    

                              point in the regeneration position and then restarts at that point when the power is re

                              stored. The time will be offset by the increment of time the unit was

 

without power, so it is   

 

                necessary to reset the time of day on  the unit. No other system will be affected.

Starting Extra Regeneration Cycle

1. To Start 

Delayed Extra Cycle

 

 

 

Example

 (  

1

  )  - 

  

If Days Remaining Until Next    

Regeneration does not read ‘1’, press and hold the

  

Set/Change

 button for 3 seconds until the display reads ‘1’.

 

Regeneration cycle will initiate at the next designated regeneration time.

2. To start 

Immediate Extra Cycle 

               

First complete above step. 

 

With Days Remaining Until Next Regeneration at ‘1’.

 

Press and hold the 

Set/Change

 button.

 

After 3 seconds, the regeneration cycle will begin.

3. To 

Fast Cycle 

thru regeneration 

First complete above 2 steps.

 

Note

:

 Press and hold the 

Set/Change

 button for 3 seconds to advance to the next cycle step.

 

Fast Cycle is not necessary unless desired to manually step through each cycle step.

 

(Repeat until valve returns to the home display)

 

Set Up Using Buttons and Display on Valve

Содержание SIDEWINDR SW10

Страница 1: ...Installation Operation Manual...

Страница 2: ...ke from a few seconds to a minute depending on the amount of oxygen and the pressure This noticeable side effect tells you the system is working properly and also will actually enhance the palatabilit...

Страница 3: ...quirements Page 6 Set Up Utilizing Bluetooth App Page 10 Set Up Using Buttons and Display on Valve Page 13 Master Programming Page 16 Control Valve Power Assembly Page 17 Valve Body Assembly Page 19 T...

Страница 4: ...l plastic Noryl threaded fittings Specifications General Specifications SW10 SW13 Smart Blend Media Capacity cu ft 1 5 cu ft 2 5 cu ft Mineral Tank Size 10 x 54 13 x 54 Service Flow Rate Continuous gp...

Страница 5: ...loosely Use caution with lubricated O rings 2 Attach the mounting screw in the bottom before completely tightening the plumbing connections 3 Attach air intake tubing to push lock elbow on side of con...

Страница 6: ...obtain di electric unions to prevent dissimilar metal corrosion Note Where the drain line is elevated above the control valve or exceeds 20 feet in length to reach the drain use 3 4 I D drain line tu...

Страница 7: ...m being plugged with floating media on initial backwash H Remove funnel and clean filter media from tank threads I Remove cap from distributor tube J Replace tank closure on mineral tank 3 Turn OFF ma...

Страница 8: ...runs clear close the tap NOTE Any time media other than very fine mineral on initial startup is apparent in the service lines it usually indicates one of the following problems A The unit is plumbed i...

Страница 9: ...in to REGISTER YOUR PRODUCT online at www watersoftinc com 4 Leave this manual with the homeowner Important Notice The plumbing system piping pressure tank hot water tanks softeners etc that have been...

Страница 10: ...the default password the first time you connect to it the app will ask you to enter the password After entering it the first time you should not need to enter it again unless it changes 3 BTLE Valve d...

Страница 11: ...s in ORANGE with a set button can be changed For Filters Set Backwash Frequency This sets the amount of day between backwash cycles Change Time of Day Press SET to set time automatically based on devi...

Страница 12: ...p Option 2 Touch any graph to enlarge and see details Enlarged graphs are able to be zoomed in by pinching with two fingers Enlarged graph shown below Regenerate Unit at Next Regen Time button This wi...

Страница 13: ...in at the set Backwash Time A 00 setting will cancel this feature The Max Value for this item is 29 Example Every 6 days A 06 Default Setting To Adjust this Value Press the Set Change Button To Accept...

Страница 14: ...where it left off prior to the power interruption When used without battery back up during a power failure the unit stops at its current point in the regeneration position and then restarts at that po...

Страница 15: ...after running water in the backwash step Note Depending upon system pressure and other factors it is possible to observe a small amount of flow to drain in the rest cycle Step 4 Air Replenish Default...

Страница 16: ...y screen The number of minutes allotted for the selected backwash step is displayed on the far right Change the digit values using the Set Change and Menu Enter buttons as described above Note on Air...

Страница 17: ...17 Control Valve Powerhead Assembly 3 4 5 6 7 8 10 11 15 14 13 18 17 12 16 E LETTERS IN DIAGRAM REPRESENT WIRING CONNECTIONS 1 E P M P P M 9 F F...

Страница 18: ...X125 1 7 Back Plate 20001X005 1 8 Lower Front Base For Cover 20111X002 1 9 Legacy View Motor Assy 20016X006 1 10 Lower Back Base For Cover 20111X003 1 11 Valve Cover 20111X000 1 12 6 32 X 5 16 Phillip...

Страница 19: ...19 Sidewindr Valve Body Assembly 2 8 1 3 19 20 27 14 15 AIR INJECTION ASSEMBLY Located near base of tank To Air Injection Assembly 4 21A 9 10 11 12 17 18 16 13 22 26 21B 25 24 23 5 7 6 6 6 6A...

Страница 20: ...0009X228 1 10 BLFC Ferrule 3 8 20251X305 1 11 Plug 3 8 20009X005 1 12 10 24 X 3 4 Screw SST 20001X226 2 13 3 8 Push Lock Plug 20009X010 1 14 Injector Cap 20009X001 1 15 Injector Seal 20001X224 1 16 In...

Страница 21: ...N A 5 20015X 6 33000X 7 20015X 8 20015X 9 20015X 20015X 10 GA Q06 11 57005X 12 GA R06 13 20017X 20018X 14 57005X 15 70000X 16 70000X 17 20015X 18 02105 19 20015X 20015X 20 20015X 21 20015X 22 20561X...

Страница 22: ...4 3 8 Brine Tubing per ft 57005X001 2 15 Bracket Retainer 70000X034 1 16 Sidekick Air Injection Bracket 70000X035 1 17 3 8 Push Lock Ball Valve 20015X022 1 18 Self Tapping Screw NA 2 19a 10 Sidekick M...

Страница 23: ...units 20017X284 3 1 Female Straight Slip Set optional 20017X288 4 1 NPT Straight Set optional 20017X289 5 3 4 NPT Straight Set optional 20017X307 6 1 X 3 4 Brass Sweat Connector Set optional 20017X304...

Страница 24: ...cover C To Replace Piston Assembly 1 Follow steps A1 A3 2 Disconnect the meter signal wire from the circuit board 3 Remove lower back base screws and detach lower back base 4 Remove screw and washer a...

Страница 25: ...at www watersoftinc com E To Replace Meter 1 Follow steps A1 A3 2 Unplug meter cable from front of circuit board 3 Unscrew meter assembly nut from valve body 4 Remove meter from valve body and clean o...

Страница 26: ...r Quality Check items listed in 1 and 2 Bypass valve open Close bypass valve Channeling Check for too slow or high service flow Check for media fouling Lack of aeration in water Program valve to draw...

Страница 27: ...ion If the encoder is plugged in and snapped into place skip to step 2 below If encoder is disconnected reconnect it and cycle power to clear the error 2 Disconnect powerhead from valve body cycle pow...

Страница 28: ...e following factors The electrical outlet is not powered or is switched off The power cable has come unplugged from the circuit board The power supply has come unplugged from your electrical outlet Th...

Страница 29: ...es service charges delivery expenses property damage administrative fees or any costs incurred by the purchaser in removing or reinstalling the water treatment equipment The Warranty does not cover an...

Страница 30: ...30...

Страница 31: ...31 710 Orange Street Ashland OH 44805 PH 419 289 1500 FAX 419 289 1515 www watersoftinc com 0423TV...

Отзывы: