![Waterous Eclipse Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/waterous/eclipse/eclipse_installation-operation-and-maintenance-manual_3642883054.webp)
54
|
90
Connecting the Temperature Gauge
8
Use the illustration and instructions to connect the
temperature gauge wires and components.
Note:
The wire is supplied by the installer.
1 Secure the neutral wire between the signal
terminal on the gauge and the larger spade on
the temperature sender.
2 Secure the power wire between the positive
terminal on the gauge and terminal 4 on the
relay panel.
3 Secure the neutral wire between the smaller
spade on the temperature sender and terminal
5 on the relay panel.
4 Secure the ground wire to the negative terminal
on the gauge.
5 Wire the warning light into the circuit.
6 Secure the ground wire to one of the gauge
light terminals.
7 Secure the power wire to the other gauge light
terminal.
8 If you are installing a 24 V system, wire the
resistor into the circuit.
1
3
5
2
7
6
4