manualshive.com logo in svg
background image

 

WL500

 Manual 

                                                                           Page 66   Revision 4‐10‐2019 

Pre‐installation and sanitization procedures as prescribed in this manual must be performed before 
installing the 

WL500 Water Treatment System

 
Always install indoors and place the 

Waterlogic WL500

 

Water Treatment System

 

on a firm, flat and 

stable surface.     
 
Attach the water supply line to the 1/4” feed water inlet bulkhead fitting on the back of the unit.  

Waterlogic

 requires the use of a water pressure regulator.  Water feed pressure must be between 40‐

60 psi.   Turn on the water supply and check for leaks.     

 

1.

 

Check to ensure that both the RED Power Switch and the GREEN Heater / 
Compressor switches are in the 

O=OFF 

position.  

NOTE:

  Switches have internal 

LED that illuminates when placed in 

I=ON

 position.  

 

2.

 

Connect the power cord to the back of the 

Waterlogic WL500

 

Water 

Treatment System

 

and to a 120 Volt supply. 

 

3.

 

Turn the RED Power Switch to I=ON position.   

 

       CAUTION!  

NEVER TURN ON HEATER BEFORE FILLING HOT TANK. 

GREEN Compressor/Heater Switch must be in the O=OFF position while the Hot 
Tank is empty.  Damage could occur within one minute and the overload (high 
limit) will require manual reset if heater is turned on with an empty Hot Tank.  

 

4.

 

Prime the Cold Circuit.  Holding a container under the dispensing faucet, press and hold the main 
dispensing button until a continuous flow of water is obtained.  Once a continuous flow is obtained, 
release the dispensing button.  Cold Tanks are now full.   

 

5.

 

Prime the Hot Tank.  Holding a container under the dispensing faucet, press the hot button (Button 
3) followed by the main dispensing button until a continuous flow of water is obtained.  Once a 
continuous flow is obtained, release the main dispensing button.  Hot Tank is now full.  

 

6.

 

Prime the Sparkling Circuit.  Holding a container under the dispensing faucet, press the sparkling 
button (Button 2) followed by the main dispensing button until all water is dispensed and a 
continuous flow of gas is obtained.  Once a continuous flow of gas is obtained, release the main 
dispensing button and the Sparkling Tank will regenerate itself.   

 

7.

 

Verify that the UV Lamp operates as expected (no alarm annunciated on the display). 

 

WARNING!  

ULTRAVIOLET RADIATION.  

Protect your skin and eyes against ultraviolet rays.  

Never look directly at an operating UV light. Always disconnect before removal.

 

 

8.

 

Press the cold button and dispense cold‐water into the drip tray to test the alarm.  Ensure that the 
drip tray alarm will sounds for 15 seconds, Drip Tray Fault is present on the LCD display, and the unit 
cuts off water supply.  Empty the drip tray and wipe dry.  While the drip tray is unattached from the 
front Panel dry the alarm sensor connectors.  Carefully install drip tray to avoid damage to the metal 
sensor clips.  Do not jam drip tray back into the unit and make sure it is properly seated. 

 

   GREEN                      RED 

   GREEN                      RED 

Содержание WL500 - Sparkling

Страница 1: ...ne Optional 1 8 NPT Female Thread to Compression Fitting Used to connect hose to drain fittings 1 Unpack the Waterlogic WL500 Water Treatment System and check exterior for damage WARNING WL500 WATER T...

Страница 2: ...ROPER PERSONAL PROTECTIVE EQUIPMENT Always ensure proper ventilation and use proper personal protective equipment such as gloves and eye protection when using chemicals Refer to Material Safety Data S...

Страница 3: ...cur within one minute and the overload high limit will require manual reset if heater is turned on with an empty Hot Tank Fill the Cold Circuit with Sanitizer 17 Wait 10 seconds for the unit to perfor...

Страница 4: ...least 5 minutes UV System Functional Test WARNING ULTRAVIOLET RADIATION Protect your skin and eyes against ultraviolet rays Never look directly at an operating UV light Disconnect before removing 24 D...

Страница 5: ...9 F You can monitor the Hot Tank temperature by selecting the hot button when the Temp Display is RANGING Dispense a cup of hot water to ensure the temperature odor taste is acceptable WARNING VERY HO...

Страница 6: ...or Citric Acid Based Cleaner Plastic Tubing at least 4 feet in length and assorted quick connect fittings TDS Meter and Test Strips for measuring chlorine Optional 1 8 NPT Female Thread to Compressio...

Страница 7: ...emove Fitting from CO2 Line 7 Attach Water Inlet Valve 8 Add 1 2 drops of Bleach into the Sparkling Tank through the Sparkling Water Level Sensor line 9 Connect Drain Water line and fitting to the Spa...

Страница 8: ...ank has a drain port and is the only tank that is open to atmosphere through the vent and faucet Prior to draining the Hot Tank turn the GREEN Compressor Heater Switch off O OFF and dispense 2 liters...

Страница 9: ...kling water out of the Sparkling Chamber through the faucet of the WL500 Water Treatment System into the drip tray holds 1 5 liters or other container until only CO2 gas is dispensed The Sparkling Cha...

Страница 10: ...areful not to touch UV Lamp surface as oils from your hands can cause dark spots and impact the performance of the system Always wipe off lamp with alcohol wipe or equivalent if needed Ensure lamp wir...

Страница 11: ...he knock out in base cabinet up to the CO2 IN bulkhead fitting on the back of the WL500 Always secure the CO2 bottle with a chain or strap to prevent tipping 6 Establish 40 60 psi 0 5 gal min potable...

Страница 12: ...Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration system condenser to dissipate heat Warmer environments require more clearance around th...

Страница 13: ...inuous flow of water is obtained Once a continuous flow is obtained release the dispensing button Cold Tanks are now full 5 Prime the Hot Tank Holding a container under the dispensing faucet press the...

Страница 14: ...generate the sparkling water by dispensing until a continuous flow of gas is obtained and release to let the pump inject cold water below 7 7 C 46 F into the chamber This provides Premium Sparkling Wa...

Отзывы: