manualshive.com logo in svg
background image

 

WL500

 Manual 

                                                                           Page 57   Revision 4‐10‐2019 

 

20.

 

Flush the Cold Tank.  Run several gallons of water through the faucet by dispensing cold water to 
dilute and remove the sanitizer from the cold circuit.  You can use chlorine test strips to evaluate the 
water. Once the sanitizer odor/taste has been flushed out of the cold side of the machine, move to 
the sparkling circuit. 

 

21.

 

Flush the Sparkling Chamber.  Dispense sparkling water until only gas comes out.  Let the Sparkling 
Tank regenerate.  This should take approximately 1 minute, 20 seconds.  Listen for the booster 
pump to turn off.  Repeat the sparkling water regeneration until the sanitizer odor/taste has been 
flushed out.   

 

22.

 

The sanitization process for the Cold and Sparkling Circuits is now complete.    

 
Fill the Hot Tank 
 

23.

 

Press the Hot Button (Button 3), followed by the main dispensing button to fill the Hot Tank.  Water 
will dispense from the faucet once the Hot Tank is full.  Flush until water is clear.

 

 

      

WARNING!  

HOT CIRCUIT IS NOT SANITIZED.  WATER MUST EXCEED 171

o

 F  

Water in the hot circuit is not sanitary until the temperature over 171

o

F for 5 minutes. 

Do Not Ingest and avoid contact until heater is turned on for at least 5 minutes. 

 
UV System Functional Test 
 

WARNING!

  

ULTRAVIOLET RADIATION.

  Protect your skin and eyes against ultraviolet rays.  

Never look directly at an operating UV light.  Disconnect before removing. 

 

24.

 

Dim or shield the overhead lights and peer into the machine, on top of the Cold Tank, at the UV 
connector and Retaining Cap.  The blue glow indicates that the lamp is lit. 

 

25.

 

Find the white wires delivering power to the top of the lamp assembly.  Follow the wires back until 
the electrical connector is found.  Disconnect the electrical connector and verify that the UV Lamp 
alarm annunciates.   

 

26.

 

Reconnect the UV Lamp wire connector, and cycle the Red Power Switch to clear the alarm. 

 

Compressor Test 
 

27.

 

Switch on the GREEN Compressor / Heater Switch (

I=ON)

.  Always ensure 

tanks are full of water before turning on the heater or the overload (high 
limit) will open and require manual reset.  Once the Compressor starts, the 
fan condenser also will start.  Verify the fan has started by feeling for the 
discharge of air at the rear grill of the machine.  Heat exchange is a signal 
that the refrigeration system is working. 

 

28.

 

Monitor the Cold Tank temperature on the front display of the unit by changing the Temp Display to 
RANGING.  It will take about 45 minutes for the unit to chill down to the default set point 
temperature of 41

F assuming ambient inlet water of 75

o

F. 

   GREEN                      RED 

Содержание WL500 - Sparkling

Страница 1: ...ne Optional 1 8 NPT Female Thread to Compression Fitting Used to connect hose to drain fittings 1 Unpack the Waterlogic WL500 Water Treatment System and check exterior for damage WARNING WL500 WATER T...

Страница 2: ...ROPER PERSONAL PROTECTIVE EQUIPMENT Always ensure proper ventilation and use proper personal protective equipment such as gloves and eye protection when using chemicals Refer to Material Safety Data S...

Страница 3: ...cur within one minute and the overload high limit will require manual reset if heater is turned on with an empty Hot Tank Fill the Cold Circuit with Sanitizer 17 Wait 10 seconds for the unit to perfor...

Страница 4: ...least 5 minutes UV System Functional Test WARNING ULTRAVIOLET RADIATION Protect your skin and eyes against ultraviolet rays Never look directly at an operating UV light Disconnect before removing 24 D...

Страница 5: ...9 F You can monitor the Hot Tank temperature by selecting the hot button when the Temp Display is RANGING Dispense a cup of hot water to ensure the temperature odor taste is acceptable WARNING VERY HO...

Страница 6: ...or Citric Acid Based Cleaner Plastic Tubing at least 4 feet in length and assorted quick connect fittings TDS Meter and Test Strips for measuring chlorine Optional 1 8 NPT Female Thread to Compressio...

Страница 7: ...emove Fitting from CO2 Line 7 Attach Water Inlet Valve 8 Add 1 2 drops of Bleach into the Sparkling Tank through the Sparkling Water Level Sensor line 9 Connect Drain Water line and fitting to the Spa...

Страница 8: ...ank has a drain port and is the only tank that is open to atmosphere through the vent and faucet Prior to draining the Hot Tank turn the GREEN Compressor Heater Switch off O OFF and dispense 2 liters...

Страница 9: ...kling water out of the Sparkling Chamber through the faucet of the WL500 Water Treatment System into the drip tray holds 1 5 liters or other container until only CO2 gas is dispensed The Sparkling Cha...

Страница 10: ...areful not to touch UV Lamp surface as oils from your hands can cause dark spots and impact the performance of the system Always wipe off lamp with alcohol wipe or equivalent if needed Ensure lamp wir...

Страница 11: ...he knock out in base cabinet up to the CO2 IN bulkhead fitting on the back of the WL500 Always secure the CO2 bottle with a chain or strap to prevent tipping 6 Establish 40 60 psi 0 5 gal min potable...

Страница 12: ...Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration system condenser to dissipate heat Warmer environments require more clearance around th...

Страница 13: ...inuous flow of water is obtained Once a continuous flow is obtained release the dispensing button Cold Tanks are now full 5 Prime the Hot Tank Holding a container under the dispensing faucet press the...

Страница 14: ...generate the sparkling water by dispensing until a continuous flow of gas is obtained and release to let the pump inject cold water below 7 7 C 46 F into the chamber This provides Premium Sparkling Wa...

Отзывы: