WL500
Manual
Page 56 Revision 4‐10‐2019
12.
Inspect and clean Quartz Sleeve and O‐ring. Reinstall the Quartz Sleeve and Quartz Sleeve retaining
nut. Tighten firmly to ensure proper seal. Over‐tightening can cause damage.
13.
Reinstall the UV Lamp and UV Sensor. Take care not to touch with fingers.
14.
Connect 40‐60 psi regulated, potable water supply to the water inlet bulkhead fitting located on the
back of the unit. Turn on water supply and check for leaks.
15.
Connect CO
2
gas line to
WL500
Water Treatment System
Bulkhead Inlet Fitting. Regulate to 35‐45
psi. Turn on CO
2
.
WARNING!
HIGH PRESSURE CO
2
GAS.
Use/Handle in accordance with all safety standards.
DANGER!
ELECTRICAL SHOCK HAZARD.
Do not plug in unit unless qualified. Only qualified personnel who have read and understand this
entire manual should attempt to install or service this unit.
16.
Connect
WL500
Water Treatment
System
to power, and turn on the RED
Power Switch
I=ON.
CAUTION!
NEVER TURN ON HEATER BEFORE FILLING HOT TANK.
GREEN Compressor/Heater Switch must be in the O=OFF position while
the Hot Tank is empty. Damage could occur within one minute and the overload (high limit) will
require manual reset if heater is turned on with an empty Hot Tank.
Fill the Cold Circuit with Sanitizer
17.
Wait 10 seconds for the unit to perform its diagnostics checks, depress the main dispensing button
on the front control Panel until cold water/sanitizing solution comes out the faucet.
NOTE:
Container and drain basin will be required to catch the water from the faucet.
WARNING!
Use Personal Protective Equipment. Gloves and Eye Protection Required. The first 2
or 3 gallons of water will contain concentrated sanitizer. Use extreme care!
Fill the Sparkling Chamber with Sanitizer
18.
The sanitizer solution will be injected into the Sparkling Tank by the booster pump once unit is
turned on and the Cold Tank is full. Dispense 1 liter of sparkling water into container and let
Sparkling Chamber regenerate to ensure the Sparkling Tank is full of sanitizer.
CAUTION!
USE SANITIZER COMPATIBLE WITH STAINLESS STEEL AND ACETAL PLASTIC.
Do not allow the sanitizer solution to remain in the system for more then 10‐15 minutes unless
otherwise directed by the sanitizer manufacturer.
Flushing the Sanitizer from the Machine
19.
Place a pitcher, catch basin, or other container under the faucet of the
WL500 Water Treatment
System
.
GREEN RED