background image

 

WL350

 Manual 

                                                                   Page 51 – Revision 11‐21‐2018 

INSTALLATION PROCEDURES 

 

Safety and Installation Guidelines 

Ensure all Local, State, and Federal Laws and Codes including health and safety guidelines are met 
when installing 

Waterlogic

 Equipment.   Only qualified service technicians should attempt 

installation and service of 

Waterlogic

 Equipment.     

 

WARNING!

  

ELECTRICAL SHOCK HAZARD.  

Always unplug (isolate from power supply) to prevent 

electrical shock except where electrical tests are specified.   

 

       WARNING!

  

IMPROPER SUPPLY OR CONNECTION CAN RESULT IS RISK OF SHOCK. 

Connect to a 15 amp 120V 60Hz properly grounded outlet (GFI is recommended).  Ensure polarity 
is correct and always use a 3‐prong outlet.  Consult a qualified electrician if you have any 
questions.     

 

WARNING!

  

USE ONLY Waterlogic SUPPLIED POWER CORD.

  Locate system within 5 feet of 

power supply.  Never use an extension cord or adapter.  Do not use a damaged power cord or 
plug.  Keep power cord out of heavy traffic areas and away from heat sources.  Do not, under any 
circumstances, remove ground prong or alter the power cord.  Never pull the power plug from the 
outlet with a wet hand or allow the plug to get wet.  Failure to use the supplied power cord will 
void UL Certification and Warranty.   

 

CAUTION!

  

INDOOR USE ONLY.   Nev

er expose to direct sunlight, heat sources, or ambient air 

temperature above 37°C (100°F) or below 2°C (35°F).  Install indoors and keep unit away from 
excessive humidity.  Never expose to freezing temperatures.  Ensure there is adequate clearance 
around the unit to allow refrigeration system condenser to dissipate heat.  Warmer environments 
require more clearance around the unit.  Minimum clearance around all surfaces of the machine is 
2‐inches.  Installs where the ambient temperature exceeds 27°C (80°F), require a minimum of 4‐
inches clearance for proper heat dissipation and efficient operation.    

 

CAUTION!

  

USE A WATER PRESSURE REGULATOR. Waterlogic

 will not be responsible for injury or 

damage caused by excessive water pressure.  Operating pressure must be 40 psi to 60 psi.  Be 
aware any of potential pressure surges caused by building/municipal pumping stations.   

 

CAUTION!

  

USE UV STABILIZED SUPPLY LINES.  

Feed the unit with a potable ambient or cold 

water supply only.

  

Feed water over 37°C (100°F) can damage the treatment components.  Water 

block devices and external leak detectors are strongly recommended. Locate the unit as close to 
the water supply and the electrical connections as possible.   

 

WARNING!

  

STORE AND TRANSPORT UNIT EMPTY. 

  

ALWAYS SANITIZE BEFORE USE, OR AFTER 

SYSTEM FAILURE  

The unit must be completely drained and sealed before storing to avoid stagnation and reduce 

microbiological contamination (potential bacterial growth).  Sanitize before use, or after system 
failure to eliminate any potential microbiological contaminates

 

 

Pre‐installation and sanitization procedures as prescribed in this manual must be performed before 
installing the 

WL350 Water Treatment Systems

 

Содержание WL350

Страница 1: ...y from the drip tray to drain Users will clog the drain with paper clips erasers napkins tea bags gum and various other intended items Waterlogic recommends you establish a minimum of weekly visits to...

Страница 2: ...out the faucet NOTE Container and drain basin will be required to catch the water from the faucet WARNING Use Personal Protective Equipment Gloves and Eye Protection Required The first 7 5 or 11 5 Lit...

Страница 3: ...the Sanitizer from the Machine 10 Place a pitcher catch basin or other container under the faucet of the WL350 Water Treatment System 11 Flush the Cold Tank Run several liters gallons of water through...

Страница 4: ...een indication LED on front of unit should flash 17 Disconnect power to WL350 Water Treatment System 18 Reconnect UV lamp 19 Connect power to WL350 Water Treatment System Compressor Test 20 Red Heater...

Страница 5: ...lding hot water Disable Cold and Hot Tanks 1 Turn off the Red Heater and Compressor Power Switch O OFF to disable the Heater and Compressor 2 Dispense 2 liters gallon of water through the Hot Tank to...

Страница 6: ...r and Compressor Power Switch is turned off the heater will not energize and heat the incoming tap water Following this precaution prevents exposing personnel and equipment drains catch basin etc to s...

Страница 7: ...blue tubing into the Line Bulkhead fitting at back of the WL350 Water Treatment System to allow water to drain 13 Depress Cold Water Dispense Button until all Cold Water has drained from the WL350 Wa...

Страница 8: ...stall indoors and keep unit away from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration system condenser to dissipate h...

Страница 9: ...Hot tank is now full CAUTION NEVER TURN ON HEATER BEFORE FILLING HOT TANK Red Compressor Heater Switch must be in the O OFF position while the hot tank is empty Damage could occur within one minute a...

Отзывы: