background image

 

WL350

 Manual 

                                                                   Page 45 – Revision 11‐21‐2018 

 

       WARNING!  

USE PROPER PERSONAL PROTECTIVE EQUIPMENT

 

Always ensure proper ventilation and use proper personal protective equipment such as gloves 
and eye protection when using chemicals.  Refer to Material Safety Data Sheet for specific 
requirements of each chemical product. Take all necessary precautions to prevent sanitizer 
from contacting eyes, clothing, and any other surfaces in could damage (carpets).  

 

 

2.

 

Put 1 teaspoon of sanitizer per directions or use Bleach Solution (1 teaspoon = 1/6 oz. = 5 ml = ½ 
cap full) of household bleach (Sodium Hypochlorite 5 ‐ 10% Concentration) in the Sanitizing 
Cartridge.  Always ensure sanitizer is compatible with stainless steel and acetyl plastic. 

 

3.

 

Connect sanitizing cartridge to inlet water supply and connect to inlet bulkhead fitting on back of 
unit.  Turn on water supply. 

 

4.

 

Connect power to 

WL350 Water Treatment System

.  DO NOT TURN ON RED 

COMPRESSOR & HEATER SWITCH AT THIS TIME. 

O=OFF

 

 
 
 

Fill the Cold Circuit with Sanitizer 

 

5.

 

Depress the Main Dispensing Button on the Front Control Panel until cold water/sanitizing 
solution comes out the faucet.  

NOTE:

  Container and drain basin will be required to catch the 

water from the faucet.   
 

WARNING!

  

Use Personal Protective Equipment.  Gloves and Eye Protection Required.  The first 

7.5 or 11.5 Liters (2 or 3 Gallons) of water will contain concentrated sanitizer. Use extreme 
care!  

 
6.

 

Turn off water supply and remove Sanitizing Cartridge from inlet water supply.  Reconnect water 
supply to Inlet Bulkhead Fitting. 
 

Flush Filters 
 

      

CAUTION!

  

FILTER FLUSH REQUIRED. 

 
WL350 Water Treatment Systems

 are not supplied with filters.  Filters should be configured to 

optimize your system.  Filters need to be configured and specified to do the job given the local 
water conditions, usage, maintenance schedule, and placement restrictions. 
  
In order for our filters to perform as represented and to provide the best quality water possible, it 
is essential that filters be replaced periodically. The frequency of filter changes depends upon your 
water quality and your water usage. For example, if there is a lot of sediment and/or particles in 
your water, then you will have to change your filters more frequently than a location with little to 
no sediment. Be sure to replace your filters whenever you notice a decline in the performance, 
whether it is a drop in flow rate and/or pressure or an unusual taste in the water. 

 

Содержание WL350

Страница 1: ...y from the drip tray to drain Users will clog the drain with paper clips erasers napkins tea bags gum and various other intended items Waterlogic recommends you establish a minimum of weekly visits to...

Страница 2: ...out the faucet NOTE Container and drain basin will be required to catch the water from the faucet WARNING Use Personal Protective Equipment Gloves and Eye Protection Required The first 7 5 or 11 5 Lit...

Страница 3: ...the Sanitizer from the Machine 10 Place a pitcher catch basin or other container under the faucet of the WL350 Water Treatment System 11 Flush the Cold Tank Run several liters gallons of water through...

Страница 4: ...een indication LED on front of unit should flash 17 Disconnect power to WL350 Water Treatment System 18 Reconnect UV lamp 19 Connect power to WL350 Water Treatment System Compressor Test 20 Red Heater...

Страница 5: ...lding hot water Disable Cold and Hot Tanks 1 Turn off the Red Heater and Compressor Power Switch O OFF to disable the Heater and Compressor 2 Dispense 2 liters gallon of water through the Hot Tank to...

Страница 6: ...r and Compressor Power Switch is turned off the heater will not energize and heat the incoming tap water Following this precaution prevents exposing personnel and equipment drains catch basin etc to s...

Страница 7: ...blue tubing into the Line Bulkhead fitting at back of the WL350 Water Treatment System to allow water to drain 13 Depress Cold Water Dispense Button until all Cold Water has drained from the WL350 Wa...

Страница 8: ...stall indoors and keep unit away from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration system condenser to dissipate h...

Страница 9: ...Hot tank is now full CAUTION NEVER TURN ON HEATER BEFORE FILLING HOT TANK Red Compressor Heater Switch must be in the O OFF position while the hot tank is empty Damage could occur within one minute a...

Отзывы: