background image

 

WL350

 Manual 

                                                                   Page 47 – Revision 11‐21‐2018 

UV System Functional Test 
 

WARNING!

  

ULTRAVIOLET RADIATION.

  Protect your skin and eyes against ultraviolet rays.  

Never look directly at an operating UV light.  Disconnect wiring before removing. 

 

14.

 

Remove UV Firewall Lamp from Firewall housing.  Remove Top Cover from Firewall housing.  
Carefully remove Quartz Sleeve Spiral from Firewall Housing and inspect for cracks or other 
damage.  Reinsert Quartz Sleeve Spiral, replace Top Cover of Housing.  Inspect UV lamp and 
reinsert into Housing. 
 

15.

 

Press dispensing button and check for blue glow from top of Firewall Housing and at Faucet 
dispensing area to ensure UV lamp is operational. 

 

Note

:  UV Lamp Sensor is temperature sensitive.  During extended periods of use, especially when 

filling or draining the unit, when water is not being dispensed UV lamp sensor can overheat 
initiating a UV fault.  If this occurs turn off unit for 5 minutes and allow sensor to cool before 
resuming operation 

 

16.

 

Disconnect UV lamp to test UV lamp sensor operation.  Unit should alarm and green indication 
LED on front of unit should flash. 

 

17.

 

Disconnect power to 

WL350 Water Treatment System.

 

 

18.

 

Reconnect UV lamp. 

 

19.

 

Connect power to 

WL350

 

Water Treatment System.

 

 

Compressor Test 
 

20.

 

Red Heater & Compressor to be in the on position 

I=ON

.  Always ensure tanks are 

full of water before turning on the heater or the overload (high limit) will open and 
require manual reset.  If the wire condenser at back of the unit is warm, the 
refrigeration system is working.   

I=ON

 

 

 

21.

 

Once the 

WL350 Water Treatment System

 reaches its target temperature, the compressor will 

shut off.  Draw a glass of cold water and verify it is has chilled to proper temperature. 

 

Heater Test 
 

22.

 

Always ensure tanks are full of water before turning on the Heater or the Overload (High Limit) 
will open and require manual reset.  It will take the heater approximately 10 minutes to heat the 
water from ambient 24°C (75°F) to the factory set point of 87°C (187°F).  Dispense a cup of hot 
water to ensure the temperature/odor/taste is acceptable.

 

 

WARNING!  

HOT WATER CAN BURN OR SCALD. 

The

 WL350 Water Treatment System 

produces Hot Water up to 87°C (187°F).

 Water above 52°C (125°F) can cause severe burns or 

scalding.  Hot water should be dispensed carefully into insulated container to avoid injury.

 

Содержание WL350

Страница 1: ...y from the drip tray to drain Users will clog the drain with paper clips erasers napkins tea bags gum and various other intended items Waterlogic recommends you establish a minimum of weekly visits to...

Страница 2: ...out the faucet NOTE Container and drain basin will be required to catch the water from the faucet WARNING Use Personal Protective Equipment Gloves and Eye Protection Required The first 7 5 or 11 5 Lit...

Страница 3: ...the Sanitizer from the Machine 10 Place a pitcher catch basin or other container under the faucet of the WL350 Water Treatment System 11 Flush the Cold Tank Run several liters gallons of water through...

Страница 4: ...een indication LED on front of unit should flash 17 Disconnect power to WL350 Water Treatment System 18 Reconnect UV lamp 19 Connect power to WL350 Water Treatment System Compressor Test 20 Red Heater...

Страница 5: ...lding hot water Disable Cold and Hot Tanks 1 Turn off the Red Heater and Compressor Power Switch O OFF to disable the Heater and Compressor 2 Dispense 2 liters gallon of water through the Hot Tank to...

Страница 6: ...r and Compressor Power Switch is turned off the heater will not energize and heat the incoming tap water Following this precaution prevents exposing personnel and equipment drains catch basin etc to s...

Страница 7: ...blue tubing into the Line Bulkhead fitting at back of the WL350 Water Treatment System to allow water to drain 13 Depress Cold Water Dispense Button until all Cold Water has drained from the WL350 Wa...

Страница 8: ...stall indoors and keep unit away from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration system condenser to dissipate h...

Страница 9: ...Hot tank is now full CAUTION NEVER TURN ON HEATER BEFORE FILLING HOT TANK Red Compressor Heater Switch must be in the O OFF position while the hot tank is empty Damage could occur within one minute a...

Отзывы: