WaterLogic WL 1000 GF Скачать руководство пользователя страница 7

12

13

Waterlogic 1000 GF Technical Manual - Issue A, July 2011

Main Parts Layout  

Hot, Cold and Ambient

1

2
3
4
5

7

8

9

11

12

31

32

34

42 383736

39

48

44

45

46

50

51

52

53

49

49

57

58

59

60

69

70 66 65

68

67 64

63

62

78

77

76

75

73

72

71

74

79

80

81

61

56

54

55

47

41 40

43

35

33

29
30

13

14

15

25

26

27

2823 24

16

17

18

19/20

/21/22

6

10

Item Part 

Number 

Description 

1

Pl-1254

Top Cover

2 Pl-1290

Carbon Air Filter Cap

3 Pu-4108

Carbon Air Filter

4 Pl-1259

Reservoir Cover

5 Pu-4099

Reservoir Seal-Silicon

6 Pu-4100

Water Level Control

7 Pu-4097

Mechanical inlet valve

8 Pl-1258

Reservoir

9 St-8212

Side Panel-Right

10 Ct-2031

Drain

11 Pl-1123

Plastic Handle Silver

12 St-8229

Lower Panel Fixing BKT

13 St-8016

Foot

14 Lp-7180

LED Label

15 Pl-1257

Front Hatch

16 En-6112

Main PCB

17 En-6114A

Sub PCB

18  

Sub PCB Cover

19 Pl-1264

Ambient Push Button

20 Pl-1263

Cold Water Push Button

21 Pl-1262

Hot Water Push Button

22 Pl-1265

Hot Safety Button

23 Pl-1266

Hot Safety Push Pin

24 Pl-1268

Faucet Pin

25 Cst-8326

Spring - for push Button

26 Pl-1269

Push Button BKT

27 Cst-8327

Spring for Hot water lock

28 Pl-1267

Hot Water Safety Lock

29 Pl-1270

Drip Tray Grill

30 Pl-1211-A

Drip Tray Body

31 Pl-1255

Front Upper Panel

32 Pl-1260A

Hot water Faucet 

33 Pl-1260C

Cold & Ambient faucet 

34 Pl-1256

Front Down Panel

35 Pl-1149A

Front Down Panel Insert

36 Ro-005A

Post-Carbon Micro filter

37 Ro-002A

Pre-Carbon Micro filter

38 Ro-001A

Sediment  Micro filter

39 Ro-008

Elbow Fitting 1/4' to1/4'

40 Pu-4024

Clip 3'

41 Ro-011B

Flow Restrictor Micro

42 ST-8206A RO BKT
43 RO-0023

Inline RO 50GPD Micro filter

44 RO-012

Adapter

Item Part 

Number   Description 

 

45 RO-017

Adapter BKT

46 CT-2035D RO Water Pump
47 ST-8254

Low Pressure Valve BKT

48 RO-013A

Low Pressure Valve Micro

49 CO-9001B Compressor 230V
50 PU-4100B GF Level Sensor

51 ST-8232

GF Level Sensor BKT 

for Leak

52 PL-1292

GF Leak Tray

53 ST-8035

Down Base

54 ST-8233

Cover of Inlet SV

55 PU-4104

JG Adaptor 1/4" for inlet 

solenoid valve

56 ST-8212

Side Panel-Left

57

/

/

58 PU-4095

Inlet Solenoid Valve 230V

59 ST-8214

Inlet Solenoid Valve Bracket

60 PL-1123

Plastic Handle Silver

61

/

Bulkhead Fitting 1/4' to 1/4'

62 ST-8210

Back Panel

63 EL-5044CN Chinese Ballast with 

metal cover 

64 CT-2070

Thermostat for GF Cold Tank 

65 ST-8230A Access panel for electronics 
66 ST-8052

Power Socket BKT

67 EL-5004

Red Switch

68 EL-5005

Green Switch

69 EL-5053

Fuse Holder & Fuse 

70 EL-5029

Power Socket

71 CT-2001-B UV Lamp Fixing Rubber 

(Silicon)

72 PL-1128

UV Lamp Retaining  

Threaded Nut

73 CT-2001

UV Lamp

74 ST-8211

Upper Base

75 CT-2006

O - Ring

76 CT-2002

Quartz Sleeve

77 CT-2069

Cold Tank

78 HT-3029

Hot Tank

79 ST-8120

Hot Tank BKT

80 PL-1261

Water Inlet Port to tank

81 PU-4109

Silicon Seal of Water 

Inlet Port

Содержание WL 1000 GF

Страница 1: ...Waterlogic 1000 GF Technical Manual Issue A July 2011 WL 1000 GF Technical Manual ...

Страница 2: ...n Parts Layout 10 Pre Delivery Inspection PDI 16 Installation 18 Operating Instructions 21 Maintenance and Service 23 Reverse Osmosis Specification 25 Sanitization 26 Fault Finding 26 Technical Specifications and Warranties 28 Electrical Schematic Diagram PCB 29 Wetted Parts 30 End of Life 32 Biocote frequently asked questions 33 ...

Страница 3: ... It is made with Biocote additive to inhibit any bacteria growth The level of the header tank is controlled by an electrical float switch which controls the inlet solenoid valve and Reverse Osmosis System There is a mechanical float valve to control any tank overfill and gives an overfill failsafe feature HOT TANK 1 5 litres The hot tank has a capacity of 1 5 litres and is made of stainless steel ...

Страница 4: ...ine COMPRESSOR The compressor operates at 220 240V at 50Hz It uses 75 grams of R134a non Ozone depleting refrigerant gas Do not place the machine too near a heat source as it will affect the compressor efficiency WATER PIPE AND FITTINGS The inlet water pipe adaptor and the internal water circuit pipe sizes are 1 4 5 16 and 3 8 The entire internal water circuit and all the components which come in ...

Страница 5: ... Filter Parts Layout Hot Cold and Ambient HOT TANK IN Water HOT WATER OUT COMPRESSOR SEDIMENT PRE CARBON MEMBRANE POST CARBON COLD WATER OUT AMBIENT WATER OUT LOW PRESSURE VALVE COLD TANK INLET SOLENOID VALVE WASTE WATER CONTROLLER FILTER DRYER PUMP RESERVOIR ...

Страница 6: ... 8 Front Hatch panel 9 Ambient push button 10 Cold water push button 11 Hot water push button 12 Hot safety push button 13 Drip tray insert panel 14 Drip tray grill 15 Drip tray body Item Description 16 Front down insert panel 17 Front down panel 18 Back panel 19 Thermostat 20 Power Switch 21 Socket 22 Fuse holder 23 Solenoid valve 24 JG fitting adaptor 25 GF insert solenoid valve cover BKT 26 GF ...

Страница 7: ... faucet 34 Pl 1256 Front Down Panel 35 Pl 1149A Front Down Panel Insert 36 Ro 005A Post Carbon Micro filter 37 Ro 002A Pre Carbon Micro filter 38 Ro 001A Sediment Micro filter 39 Ro 008 Elbow Fitting 1 4 to1 4 40 Pu 4024 Clip 3 41 Ro 011B Flow Restrictor Micro 42 ST 8206A RO BKT 43 RO 0023 Inline RO 50GPD Micro filter 44 RO 012 Adapter Item Part Number Description 45 RO 017 Adapter BKT 46 CT 2035D...

Страница 8: ...evel sensor BKT for Leak 19 Compressor 20 Cover of Inlet SV 21 Inlet Solenoid Valve washing Machine Inlet GF 22 Culligan Filter BKT 23 Hot Tank 24 Cold tank 25 Upper Base 26 Water Inlet port to tank 27 Silicon Seal of Water inlet Port 28 Sub PCB 29 Sub PCB Cover 30 Reservoir 31 Reservoir Seal Silicon 32 Electrical water Level Control 33 Carbon Air Filter Cap 34 Reservoir Cover 35 Mechanical Water ...

Страница 9: ...ect electrical connections water con nections and that the filters and RO membrane are located correctly 7 Connect to a potable drinking water supply limited to 3 bar via a 1 4 John Guest tube and adapter 8 Connect the reject water drain tube to a suitable waste away or re use system 9 Ensure the red switch at the rear of the machine is off now connect to an ap propriate power supply 10 Turn on wa...

Страница 10: ...WL 1000 GF The minimum pressure for the WL 1000 GF to function correctly is 22 5 PSI 1 5 bar The ideal pressure is 45 PSI The maximum pressure is 60 PSI 8 Check the electrical wall socket polarity and then make the electrical connec tion to the WL 1000 GF by plugging the power lead in to the socket on the rear of the WL 1000 GF Then connect to the electrical feed wall power outlet and turn on the ...

Страница 11: ...nd carbon filters on the WL 1000 GF must be changed every 6 months The UV lamp on the WL 1000 GF must be changed every 6 months The cold tank and header tank should also be flushed and sanitised every 6 months Waterlogic International strongly recommends the use of an anti flood device Figure 1 is the recommended installation kit Fig 1 Waterlogic Installation Kit Dispensing your choice of water is...

Страница 12: ...ent filters and UV lamp must be changed The Reverse Osmosis Membrane must be changed every 24 months The quartz sleeve must be removed checked and cleaned every six months If you remove the quartz sleeve from the cold tank you will need to drain the header tank first as the tank will still be pressurised from the head of water stored in the tank The 1000GF header tank should be inspected and remov...

Страница 13: ...quired to prevent a fault Clean the refrigeration condenser grill if required 12 Make sure there is a 5cm air gap around the machine and is free from any obstructions 13 Turn on only the Green switch at the rear of the WL 1000 GF 14 Flush only the cold and ambient water for 5 litres to generate the filters and all traces of Sanitizer has been removed This can be checked by using Chlorine test stri...

Страница 14: ... water is not hot and cold water is not cold Make sure the green and red heater and compressor switches are turned on Check that the machine power indicator light is on 4 There is hot water flow but cold water is not flowing This may be due to the cold water tank being frozen If so disconnect power supply for one hour to allow the tank to defrost and then flush the cold water system Check the cold...

Страница 15: ...any warranties accompanying the sale of our products will be invalidated by any of the following Incorrect installation Incorrect use of the WL 1000 GF Unsuitable electrical and water supply Major short coming of maintenance Technical interventions or alterations of an unauthorised nature Adoption and use of unapproved spare parts Engagement of untrained personnel Waterlogic has a policy of consta...

Страница 16: ...t to Tank 21 PU 4126KR DeaMyung PE 1 2 Pipe 22 HT 3030 GF Hot Tank Ass y 1 5 Liter220V 500w 23 PU 4112 Gravity Silicon Pipe 48 5 155 Elbow WITH BIOCOTE 24 PU 4101 PP Straight Connector for Silicon Pipe 25 PU 4126KR DeaMyung PE 1 2 Pipe Item Part Number Description 26 PU 4112 Gravity Silicon Pipe 48 5 155 Elbow WITH BIOCOTE 27 PL 1260A Gravity Faucet Assy Left Inlet Hot POM Silicon Assy WITH BIOCOT...

Страница 17: ...l protection BioCote s silver technology has been tested by an independent laboratory to show its ability to inhibit the growth of bacteria mould and fungi by up to 99 9 over a 24 hour period and for the duration of the machine life FREQUENTLY ASKED QUESTIONS ABOUT BioCote Why use BioCote BioCote will help reduce the risk of cross contamination You may not want to think about it but every surface ...

Страница 18: ... Beacon Court Sandyford Dublin 18 Ireland www waterlogic com Waterlogic USA 4141 N 156th Street Omaha NE 68116 Speak to a Water Expert Rest of the world exportsales waterlogic com 353 1 293 1960 USA Canada and Mexico info waterlogicusa com 1 402 884 7212 ...

Отзывы: