Machine Overview
WATERLOGIC 1000 GF
COLD TANK CAPACITY (4 Litres)
The cold tank is manufactured from 304 Stainless Steel which is noncorrosive and
inert. The temperature of the Cold Tank is controlled by a mechanical thermostat
located on the rear panel of the machine and can be set between 3°C and 12°C. We
recommend the cold water is set at 5°C, which is the factory setting and is the ideal
temperature for a cold drink. The set point for the thermostat is marked with a
black dot.
HEADER STORAGE TANK (11.5 Litres)
The plastic header tank has a capacity of 11.5 litres of purified water. This tank can
be drained and removed from the machine for cleaning. It is made with Biocote
additive to inhibit any bacteria growth.
The level of the header tank is controlled by an electrical float switch which controls
the inlet solenoid valve and Reverse Osmosis System. There is a mechanical float
valve to control any tank overfill and gives an overfill failsafe feature.
HOT TANK (1.5 Litres)
The hot tank has a capacity of 1.5 litres and is made of stainless steel. The water
temperature is controlled by a Mechanical Thermostat and is factory set at 85°C. A
thermal high temperature cut out is fitted to the Hot Tank and the tank has a 500
Watt immersed heating element. The high temperature cut out has a manual reset
button, please isolate the power before resetting. The hot water tank is a sealed unit.