24
25
Waterlogic 1000 GF Technical Manual - Issue A, July 2011
6.
To sanitise the cold tank introduce sanitisation fluid or a Chlorine tablet through
the UV port directly into the cold tank before putting the quartz sleeve back in
place.
7.
Refit the quartz sleeve and replace the UV lamp and reconnect the UV loom.
Do not touch the UV lamp with your bare hands as this will shorten the lamp life.
8.
Refit the header tank and inspect all water connections and turn on the power
and water.
9.
Back flush the Reverse Osmosis Membrane.
10.
Check that the Reverse Osmosis rejected water drain flows freely; any blockage
will cause damage to the membrane. The machine will start to re-fill when the
back flush valve is closed
11.
Carry out a visual inspection of the WL 1000 GF water and electrical connections
and components and take any remedial action required to prevent a fault. Clean
the refrigeration condenser grill if required.
12.
Make sure there is a 5cm air gap around the machine and is free from any
obstructions.
13.
Turn on only the Green switch at the rear of the WL 1000 GF.
14.
Flush only the cold and ambient water for 5 litres to generate the filters and all
traces of Sanitizer has been removed. This can be checked by using Chlorine test
strips. Then flush the hot tank to ensure it is full of water and then turn on the red
switch at the rear of the WL 1000 GF. The unit will now heat and cool.
15.
Replace the top cover and lower front panel and wipe the outside surfaces
(nonabrasive cleaner), and clean the drip tray.
16.
Taste the water, and test that the WL 1000 GF functions to the customer’s
satisfaction. Should there be any taste issues with the water then flush the WL
1000 GF again.
SPECIFICATIONS:
• Leak protection
• Pre-Sediment Filter
• Pre-Carbon Filter
• Low Pressure Switch
• Water Pump
• Reject Water Flow Controller
• Manual Back Flush By-Pass Valve
• RO Membrane 50GPD
• Post Carbon Filter