DRAINING
TOWER INSTRUCTIONS
Draining Notes
Drain the Waterlogic
infiniti Water Treatment System,
for transportation.
WARNING! STORE UNIT EMPTY. ALWAYS SANITIZE BEFORE REUSE.
The unit must be completely drained and sealed before storing to avoid stagnation and reduce
microbial growth).
Prior to draining the hot tank, turn off the Red Heater and Compressor Power
Switch (
O=OFF)
, and dispense 2 liters of hot water from the machine. As hot
water is dispensed from the faucet of the
infiniti Water Treatment System
,
colder water will be introduced into the hot tank. Since the Red Heater and
Compressor Power Switch is turned off, the heater will not energize and heat the
incoming tap water. Following this precaution prevents exposing personnel and equipment
(drains, catch basin, etc.) to scalding hot water.
Disable Cold and Hot Tanks
1.
Turn off the Red Heater and Compressor Power Switch (O-OFF) to disable the
heater and compressor.
2.
Dispense 2 liters of water through the hot tank to cool the water temperature
in the hot tank and avoid burns.
WARNING! HOT WATER.
The
infiniti Water Treatment System
produces Hot Water up to 188°F.
Water above 125° can cause severe burns or scalding. Hot water should be dispensed carefully
into insulated container to avoid injury.
Turn off Water Supply and Bleed Water Pressure
1.
Isolate the
infiniti Water Treatment System
from feed water by turning off the supply.
2.
Dispense cold still water to relieve any pressure built up in the system.