infiniti
Operating, Installation, and Service Manual Page 15 - Revision: 9-15-2016
Waterlogic
infiniti
COUNTER TOP
DRAINING INSTRUCTIONS
Draining Notes
Drain the
Waterlogic infiniti
Water Treatment System
for transportation.
WARNING!
STORE UNIT EMPTY. ALWAYS SANITIZE BEFORE REUSE.
The unit must be completely drained and sealed before storing to avoid stagnation and reduce
microbial growth.
Prior to draining the hot tank, turn off the Red Heater and Compressor Power
Switch (
O=OFF)
.
Allow Hot Water to cool off prior to draining.
WARNING!
HOT WATER.
The
infiniti Water Treatment System produces Hot Water up to
188°F.
Water above 125° can cause severe burns or scalding. Hot water should be dispensed
carefully into insulated container to avoid injury.
Disable Cold and Hot Tanks
1.
Turn off the Red Heater and Compressor Power Switch (
O-OFF
) to disable the
heater and compressor.
Turn off Water Supply
2.
Isolate the
infiniti
Water Treatment System
from feed water by turning off the supply.
Drain the Cold Water Tank and Circuit
3.
Remove the Front Cover.
4.
Remove the Faucet, and move the Front Cover to the top of the
infiniti
Water
Treatment System
to gain access to the draining tubes
5.
Remove tubing from JG fittings, and
allow water to drain into drains,
catch basin, etc.
6.
Reinstall tubing into JG fittings,
Faucet, and Front Cover