ICE 900 Supplemental Service Manual
Page 35 Revision 3-19-2019
CAUTION!
O-RING TO REMAIN IN PLACE AT TOP OF FILTER. Failure
to keep the O-ring in place will result in the filter leaking.
CAUTION!
DO NOT DISCARD THE O-RING AT TOP OF FILTER. Filters
are not supplied with the O-Ring.
FLUSH PRE-CARBON FILTER
3.
Plug power cord in.
4.
Turn off Incoming Water Supply.
5.
Remove white tube above Sediment Filter on the Filter Block.
6.
Install a tube that will reach the drain or bucket that will be used to collect
water used in filter flushing process.
7.
Remove Sediment Filter and set aside by unscrewing filter from filter block
by hand or using a strap wrench if needed.
Flushing of the filters will take place in the Sediment Filter Location
8.
Install Pre-Carbon Filter into the now empty Sediment Filter Location.
9.
Turn on Incoming Water Supply