ICE 900 Supplemental Service Manual
Page 46 Revision 3-19-2019
TROUBLESHOOTING TIPS
1.
The Ice 900 RO system and ice storage bin must both be hooked to a floor drain. You can use a
one-way check valve to prevent backflow and tee the lines together to reduce overall drain line
requirements.
2.
The Ice Motor Coupler is designed to be the “weak link” – when the ice tray goes to dump and
the ice is built up abnormally in the top tray or frozen solid, it won’t dump and the coupler is
designed to break. This is not a coupler issue, but rather a result of a bad ice cycle that jams the
ice tray and breaks the coupler.
a.
Change All Sensors
b.
Replace Coupler
c.
Check Ice Production – See sample pictures below:
3.
Auto Flush Valve (AFV) is used to clean the RO membrane at start up by allowing more water to
drain to flush contaminants from the surface of the membrane.
4.
You can use and additional sediment filter for added capacity in locations where sediment filter
requires more frequently changes than desired. The pre-sediment filter could be placed outside
of the unit. Inside would be ideal to provide leak protection.
5.
You can check all sensors by ohm meter and calibration chart to determine resistance at a range
of temperatures. See chart in technical manual. Change all sensors to be proactive and limit
costly down time.
ICE SAMPLE PICTURES
ICE CUBE SHOULD BE JUST LARGER
THAN A QUARTER AT THE BASE
ICE CUBE SHOULD NOT HAVE TAIL
OR BE MIS-SHAPED.
12 proper size and shape ice cubes should be produced every 11-12 minutes once ice making
starts. Time and inspect ice shape and size to ensure ice making process is within proper
tolerance or sensors could be out of calibration.