ICE 900 Supplemental Service Manual
Page 5 Revision 3-19-2019
WARNING!
SUPERVISE CHILDREN.
Keep appliance and cord out of reach of children under the age of
8 years. Children under the age of 8 years must not use or play with the appliance.
WARNING!
DO NOT OPERATE IF DAMAGED OR MALFUNCTIONING. Unplug if abnormal case
occurs. Contact Waterlogic or authorized dealer for repair, service, and installation to avoid hazards.
WARNING!
UNIT PRODUCES HOT WATER. Water above 52
o
C (125
o
F) can cause severe burns or
scalding. Keep unauthorized people and children away from the unit to avoid accidental dispensing
of hot water. Always use an appropriate heat-resistant container for hot water dispense.
WARNING!
CONNECT TO POTABLE WATER SUPPLY. This system is to be used for water only and is
not intended for use where water is microbiologically unsafe or with water of unknown quality
without adequate disinfection. System is not intended for treatment of contaminated water.
WARNING!
TIP HAZARD. Dispenser could tip or fall causing serious injury. Do not attempt to install
the
ICE 900 on a surface on a sloped or unstable position. Never place heavy items on top of unit and
never climb, stand, or hang on unit or storage cabinet to prevent injury and damage. Do not tilt the
ICE 900 over 45° during transportation or installation as this may damage the compressor.
WARNING!
UNIT IS HEAVY. TWO PERSON LIFT REQUIRED. Transport unit empty and always use
material handling equipment or two people with proper lifting technique to reduce injury risk.
WARNING!
STORE AND TRANSPORT UNIT EMPTY.
ALWAYS SANITIZE BEFORE USE.
The unit must be completely drained and sealed before storing to avoid stagnation and reduce
microbiological contamination (potential bacterial growth). Sanitize before use to eliminate any
potential microbiological contaminates
CAUTION!
INDOOR USE ONLY. Never expose to direct sunlight, heat sources, or ambient air
temperature above 37°C (100°F) or below 2°C (35°F). Install indoors and keep unit away from
excessive humidity. Never expose to freezing temperatures.
Ensure there is 4-inches
of clearance
around the unit to allow refrigeration system condenser to dissipate heat. Warmer environments
require more clearance around the unit. Minimum clearance around all surfaces of the machine is 2-
inches.
Installs where the ambient temperature exceeds 27°C (80°F), require a minimum of 4-inches
clearance for proper heat dissipation and efficient
operation. Do not cover or block ventilation holes.
CAUTION!
USE A WATER PRESSURE REGULATOR. Waterlogic will not be responsible for injury or
damage caused by excessive water pressure. Input or feed pressure must be
40 psi to 60 psi. Be
aware of any potential pressure surges caused by building/municipal pumping stations. Water block
devices and external leak detectors are strongly recommended. Locate the unit as close to the water
supply and the electrical connections as possible to minimize risk.
CAUTION!
USE PROPER SUPPLY LINES AND FEED WITH POTABLE AMBIENT WATER ONLY.
Feed water over 37°C (100°F) may damage the treatment components. Always use supply lines with
adequate pressure rating and UV resistance. Close water supply valve and contact service
representative if a leak is noticed.
Contact Waterlogic for assistance or help finding an Authorized
Service Representative.