7.2.4
Connection tube of the tank (at the top) (EcoTouch Ai1 Geo)
The upper tube connection can not be directed through the insulation with an in-
stalled bleeder. Therefore, the upper part of the bleeder has to be mounted finally.
Procedure:
Remove the yellow plug
Install the tube connection at the hot water tank.
Then fit the top of the bleeder (Z13683) on the tee of the connection tube (see
pointing arrow).
Use the supplied gasket (Z13679).
Figure 8: Connection tube (at the top) with bleeder
7.2.5
Connection tube of the tank (bottom) (EcoTouch Ai1 Geo)
The lower connection tube has no bleeder. Remove the yellow plug and mount
the tube connection at the hot water tank. Use the supplied gaskets (Z13679).