background image

14 

 

 

 

ADDENDUM 2 

 

INSTALLATION INSTRUCTIONS FOR LEAK STOP FLOW INTERRUPTOR 

 

 

Waterite now includes a non-electric leak detection device, with all residential RO systems. This 

LEAK STOP

 is easy to install and will automatically shut off the incoming water being supplied to 

the RO unit if any water comes in contact with it. 

 

Simply mount on the floor of the cabinet directly under your RO unit is installed.  If a leak occurs on 

the RO system, the sensor is triggered and an internal valve closes, preventing water from running 

to the RO system and causing water damage. 

 

The 

LEAK STOP

 is supplied with a mounting bracket, two-sided tape to make installation easy. 

 

INSTALLATION INSTRUCTIONS 

(see Figure 1 below) 

For new system installations, installing the 

LEAK STOP

 should be your 

LAST

 step. 

 

1.  Turn inlet water valve off. 

2.  Using the 2-sided tape provided, place the 

LEAK STOP

 in a convenient location under the 

RO system, in a place most likely to get wet in the event of a system leak. Make sure the 

area is COMPLETELY free of moisture.  Remove the tape film and push down firmly so that 

tape adheres to surface. (Fig. 1 & 2) 

3.  Remove the red locking rings from the ports on the 

LEAK STOP

 device. (Fig. 3) 

4.  If desired you can also fasten the bracket directly to the base of the cabinet by using the 

screw holes provided on the base of the 

LEAK STOP

. (Fig. 1) 

5.  From the shut off valve on the main feed line, attach the ¼” (10mm) tube to the inlet side (IN) 

of the 

LEAK STOP

 device. (Fig 3) 

6.  From the outlet (OUT) side of the 

LEAK STOP

, connect a ¼” (10mm) tube to the cold-water 

inlet of the RO system.  (Fig. 4) 

7.  Make sure all connections are tight and that the tube has been inserted all the way into the 

LEAK STOP

 fittings. Secure the tubing with the locking rings supplied with the 

LEAK STOP

(Fig. 4) 

8. 

Turn inlet water valve on. Make sure there are no leaks around the fittings

.  

 

                    Figure 1         

          Figure 2   

              Figure 3 

                   Figure 4

 

 

 

 

 

 

 

 

 

 

                    Screw mount holes   

 

 

 

               locking clips          inlet   

                   outlet 

         

 

       

 

 

WARNING!

 

The LEAK STOP should be wrapped with a dry towel or cloth before changing cartridges. 

This will help avoid it coming into contact with water that may be accidentally spilled in the 

process.  

Should the 

LEAK STOP 

device come into contact with any water, the device will 

Содержание WR2

Страница 1: ...F THE EQUIPMENT FOR REFERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPA...

Страница 2: ...t is used to reduce chlorine many chemicals and remaining traces of taste and odour from the plumbing system Your system also includes a faucet and the hardware and tube needed to complete the install...

Страница 3: ...any installations will include an optional line to refrigerator icemakers or additional sink faucets See your dealer for advice and parts Q What is the standard warranty with the WR2 filter system Eve...

Страница 4: ...onsult your plumber or plumbing supply store to purchase an appropriate cold water connection 3 You will need the following tools An electric drill a carbide bit a carbide bit a 1 8 carbide bit a penc...

Страница 5: ...t a professional install the faucet to avoid chipping and damaging the sink finish 4 Place the Quick Faucet base in the desired location with the inside flat with the small notch facing the direction...

Страница 6: ...hat there is clearance for plumbing and mounting hardware directly below it under the sink or countertop If you have a stainless sink go to Step 4 5 8 If you have a concrete sink with a thickness of l...

Страница 7: ...ing the filter system 1 While holding the system in its mounting position mark the holes for the wall screws Using a 1 8 bit drill the pilot holes for the screws Screw in the mounting screws leaving p...

Страница 8: ...Turn on the feed water adapter valve and check all connections for leaks Do not proceed further until any leaks are fixed 2 Open the faucet at the sink and let the water run free for 10 minutes Turn...

Страница 9: ...r Rinse completely If the system has been installed with a water supply that does not contain chlorine put 2 fluid ounces 60 ml of common household chlorine bleach such as Javex in the clear housing R...

Страница 10: ...ng leaking Tighten with housing wrench Inspect o rings for cuts or crimps WR2 RESIDENTIAL FILTER SYSTEMS PARTS LIST 1 2 3 4 5 6 7 8 9 10 11 12 KEY DESCRIPTION PART NUMBER COMMENT 1 Cartridge 5 mic sed...

Страница 11: ...11 WR2 RESIDENTIAL FILTER SYSTEM FLOW LAYOUT...

Страница 12: ...e plumbing system pipes banging that could cause components or tube to break or rupture A well designed plumbing system usually incorporates shock arrestors see figure 1 to soften the effects of water...

Страница 13: ...e REGP1414E device Check the arrow on the device to make sure the flow direction is correct See figure 2 Make sure the tube is pushed all the way into the fitting and bottoms out Tug on the connection...

Страница 14: ...OMPLETELY free of moisture Remove the tape film and push down firmly so that tape adheres to surface Fig 1 2 3 Remove the red locking rings from the ports on the LEAK STOP device Fig 3 4 If desired yo...

Страница 15: ...15 be triggered and the tablet will need changing LEAK STOP refill tablet part number HDJMF0 REGISTER YOUR PRODUCT ONLINE AT WATERITE COM OR FILL OUT THE INCLUDED PRE PAID SELF ADDRESSED POSTCARD...

Страница 16: ...16 WATERITE INC Winnipeg Manitoba Canada www waterite com...

Отзывы: