10
Section 4: Troubleshooting Guide
Trouble Shooting Guide
Possible Cause
Solution
Low Water or No Water
Water supply valve closed
or tank valve closed.
Open valves
Crimped poly tube
Repair or replace
tube
Filters or membranes plugged
Replace filters
Combo filter(s) upside down
Install with
rubber gasket up
Tubes installed to wrong fitting
Install tubes per
S.8 (1), (2)
Leaking Joints
Fittings not seated
Disconnect fitting
and reseat tube
Filter housing leaking
Tighten with
housing wrench
Inspect o-rings
for cuts or crimps