ENVISION AIR COILS INSTALLATION MANUAL

WARNING: Before performing service or 
maintenance operations on a system, turn off main 
power switches to the equipment. If applicable, 
turn off the accessory heater power switch. 
Electrical shock could cause personal injury. 

Installation and servicing heating and air conditioning 
equipment can be hazardous due to system pressure and 
electrical components. Only trained and qualified service 
personnel should install, repair or service heating and air 
conditioning equipment. Untrained personnel can perform 
the basic maintenance functions of cleaning coils and 
cleaning and replacing filters. All other operations should 
be performed by trained service personnel. When working 
on heating and air conditioning equipment, observe 
precautions in the literature, tags and labels attached to the 
unit and other safety precautions that apply.

Follow all safety codes. Wear safety glasses and work 
gloves.  Use a quenching cloth for brazing operations and 
have a fire extinguisher available.

NOTE:

  Local codes and regulations take precedent over 

any recommendations by the manufacturer. In addition to 
conforming to manufacture’s and local municipal building 
codes, the equipment should be installed in accordance 
with the National Electric Code and National Fire Protection 
Agency recommendations.

 

Model Nomenclature

Initial Inspection

When the equipment is received, all items should be 
carefully checked against the bill of lading to be sure all 
crates and cartons have been received. Examine units 
for shipping damage, removing the units from packaging 

if necessary. Units in question should also be internally 
inspected. If any damage is noted, the carrier should make 
the proper notation on the delivery receipt, acknowledging 
the damage.

Safety Considerations

NR

A

C

026

C

Model Type

Cabinet

   NR = Envision Series Refrigerant Coils

  NH = Envision Series Hydronic Coils

   C = Encased

  U = Uncased

Configuration

  A = “A” Coil

Capacity

Refrigerant Models

  026 MBTUH

  036 MBTUH

  048 MBTUH

  060 MBTUH

Hydronic Models

  060 MBTUH

Coil

NOTE: 

All Refrigerant Coils include TXV.

1-2

3

4

5-7

8

Содержание Envision NHAC026

Страница 1: ...IM1618 09 09 Envision Air Coils Installation Manual Dimensional Data Installation Information Maintenance Geothermal Water Source Heat Pumps R 410A Refrigerant 2 5 Ton ENCASED UNCASED AIR COILS...

Страница 2: ......

Страница 3: ...AIR COILS INSTALLATION MANUAL Table of Contents Model Nomenclature 3 Initial Inspection 3 Safety Considerations 3 Dimensional Data 4 5 General Installation Information 6 9 Hydronic Models 10 11 Maint...

Страница 4: ...nching cloth for brazing operations and have a fire extinguisher available NOTE Local codes and regulations take precedent over any recommendations by the manufacturer In addition to conforming to man...

Страница 5: ...4 1 23 4 16 8 2 1 2 0 cm 52 8 66 0 73 9 2 2 2 2 1 9 48 3 61 2 59 4 42 7 5 3 5 1 Encased Models Refrigerant Water Connections Condensate Connections Miscellaneous J K L M N O P Q R S T U V W X Y Z AA A...

Страница 6: ...ls A B C Suction Liquid Condensate D E F G H I J K L Width Depth Height Sweat Sweat FPT NRAC026 036U in 20 0 24 9 20 7 5 8 3 8 3 4 15 0 17 5 0 7 1 3 10 0 3 0 1 7 7 0 13 3 cm 50 8 63 3 52 6 1 6 1 0 1 9...

Страница 7: ...ace air circulators may have to be replaced with multispeed blowers to upgrade the air delivery CFM when an add on coil is installed Refer to the Encased and Uncased Coil Specification table for recom...

Страница 8: ...lications follow the steps shown below Remove all access panels Remove the A coil assembly 1 and the horizontal drain pan From the vertical upflow position rotate the top of the 2 cabinet 90 to the ri...

Страница 9: ...NRAC036 5 8 OD 3 8 OD 3 4 OD 3 8 OD 3 4 OD 1 2 OD NRAC048 3 4 OD 3 8 OD 7 8 OD 3 8 OD 7 8 OD 1 2 OD NRAC060 7 8 OD 1 2 OD 7 8 OD 1 2 OD 1 1 8 OD 1 2 OD Encased and Uncased Refrigerant Line Sizing NOT...

Страница 10: ...to a drain line pitched away from the unit a minimum of 1 8 per foot to allow the condensate to flow away from the coil A trap must be installed in the drain below the bottom of the pan to ensure fre...

Страница 11: ...must be equipped with an expansion tank to allow room for the heated liquid to expand A system is considered closed when a check valve or backflow prevention valve is installed in the cold water pipe...

Страница 12: ...on the coil Filter Maintenance The air filter installed with the system must be cleaned or replaced to obtain maximum performance They should be inspected monthly under normal operating conditions an...

Страница 13: ...12 ENVISION AIR COILS INSTALLATION MANUAL Notes...

Страница 14: ...13 ENVISION AIR COILS INSTALLATION MANUAL Notes...

Страница 15: ......

Страница 16: ...9 Manufactured by WaterFurnace International Inc 9000 Conservation Way Fort Wayne IN 46809 www waterfurnace com 2009 WaterFurnace International Inc 9000 Conservation Way Fort Wayne IN 46809 9794 Water...

Отзывы: