OPERATION OF YOUR POOL HEAT PUMP 

To Start the Pool Heat Pump 

 

Press  the  button 

ON/OFF

  on  the  electronic  control  to  start  the  pool  heat  pump.    The 

temperature display shows the pool water temperature flowing in your pool heat pump and 
the fan motor starts (fan blades turn) but the compressor does not start. 
 
The  temperature  display  flashes  until  the  compressor  starts  and  when  the  timer  will 
complete its cycle of 5 minutes.  After 5 minutes, the compressor starts and the temperature 
on the display stops flashing. 
 
You can now program the desired temperature for the pool water. 

 

 

To Stop the Pool Heat Pump 

 

The pool heat pump can be stopped by pressing the 

ON/OFF

 button once. 

 

To Check and Adjust Temperature Settings 

 

 

To program the desired water temperature, press 

BOTH

 the 

UP

 and 

DOWN

 arrow keys at 

the same time until the temperature displayed changes degree, then release them. 

 

Press the 

UP

 or 

DOWN

 arrow to program the desired temperature.  The temperature setting 

will automatically flash and will be saved.  The display temperature will be reverting back to 

the pool water temperature when all keys remain untouched for 5 seconds. 

 

To  change  the  temperature  display  from  Fahrenheit  (˚F)  to  Celsius  (˚C),  press  the  button 

˚C/˚F

.  The led below the 

˚F

 or 

˚C

 will be lit to indicate the current selection. 

 

Note: The pool heat pump will stop working when the programmed temperature is reached.

 

 

 

OPERATION OF YOUR POOL HEAT PUMP 

 

Pool Solar Blanket 

 

A  pool  solar  blanket  should be  used  whenever  possible.    Blankets  minimize  heat  loss  and 
conserve heat in your pool.  Un-blanketed pool loses 2-3 times more heat than a blanketed 
pool.   

STRONGLY RECOMMANDED AT THE BEGINNING AND END OF SEASON

 

 

Defrost Cycle 

 

When any of the following conditions occur, the electronic control of your unit will activate a 

defrost mode  until  all frost  from the  evaporator  has  melted.    Condensation  of  water  on  the 

evaporator coil tends to frost up quicker when the following occur. 

 

1.  When atmospheric conditions are as stated on previous page; 

2.  When the evaporator is dirty; 

3.  When installation clearances are not respected. 

 
Defrost is activated for a laps of time between 3 to 20 minutes. 

 

Electronic Control with Diagnostics and Reversible

 

(XLR) 

Electronic Control with Diagnostics

 

 

 

Reversible (XLR) Electronic 

Control with Diagnostics 

 

 

 

 

 

Electronic Control 

with Diagnostics 

 

 

 

 

 

Содержание Ultra

Страница 1: ...t Une installation inadéquate annulera la garantie Notice to Installer Avis à l installateur This manual contains important information about the installation operation and safe use of this product Once the product has been installed this manual must be given to the owner operator of this equipment Ce manuel contient des informations importantes sur l installation l exploitation et l utilisation s...

Страница 2: ...___ Compressor Starts and Stops ____________ There Is Water Around the Pool Heat Pump _ Pool Heat Pump Has Ice Formed On the Evaporator Coil _________________ Pool Heat Pump Is Not Heating ___________ Analysis Chart ________________________ Circuit Breaker Trips ___________________ Pool Heat Pump Is Noisy ________________ The Temperature Shown on Pool Heat Pump Is Not the Same than the Pool Thermo...

Страница 3: ...ded for proper operation and heating Please refer to the section Location on the following page IMPORTANT Usage of Chemical Products Never add liquid chlorine granular chlorine or slow dissolving tablets pucks into the skimmer basket This high concentration of chemicals should be avoided Water quality standards that must be strictly adhered to Warranty can be voided if not maintained within these ...

Страница 4: ...ir is pulled through the evaporator coil and discharged through the top or front grill Clearances should be allowed in front and around the unit for unrestricted air discharge and service access See Figure 1 and Figure 2 Re circulation of cold discharged air back into the evaporator coil will greatly reduce the unit s heating capacity and efficiency Pool Heat Pump Pg 06 No obstruction above Pool H...

Страница 5: ... MUST be installed between the pool heat pump and any automatic chlorinator to prevent highly chlorine concentrated water from flowing back to the pool heat pump when the pool pump is not running 2 Units that are located below the water level of the swimming pool may require the pressure switch to be adjusted This can be checked by the following method Switch ON the water pump and the pool heat pu...

Страница 6: ... these systems may leak stray voltage and currents into the water causing severe electrolysis This dramatically shortens the life of the pool heat pump and will void the warranty NOTE Bonding to pool pump is not required for above ground pool pumps but all other equipment must be bonded Pool water temperature must be above Atmospheric conditions must be above Model Ultra Reversible XLR All others ...

Страница 7: ...g back to the pool water temperature when all keys remain untouched for 5 seconds To change the temperature display from Fahrenheit F to Celsius C press the button C F The led below the F or C will be lit to indicate the current selection Note The pool heat pump will stop working when the programmed temperature is reached OPERATION OF YOUR POOL HEAT PUMP Pool Solar Blanket A pool solar blanket sho...

Страница 8: ...e XLR Electronic Control with Diagnostics Functioning of your Electronic Control with Diagnostics and Reversible XLR Electronic Control with Diagnostics OPERATION OF YOUR POOL HEAT PUMP Temperature Calibration It is possible to have a temperature variation between the water in the swimming pool and the reading of the pool heat pump temperature probe sensor Example the water in the pool is 26 ºC 80...

Страница 9: ... 70 F 21 C please adjust the bypass valve as shown Approx 60 of the water is circulating in the unit When the pool water temperature is between 70 F 21 C and 78 F 26 C please adjust the bypass valve as shown Approx 80 of the water is circulating in the unit When the pool water temperature is above 79 F 26 C please close the bypass valve as shown 100 of the water is circulating in the unit IMPORTAN...

Страница 10: ...the pool heat pump s heat exchanger in preparation for winter 4 Once the piping is disconnected the pool heat pump s heat exchanger MUST be emptied the use of a water vacuum cleaner is strongly recommended or if you do not have this tool you can tilt the unit 75 until all the water is out 5 It is recommended that the pool heat pump s heat exchanger is rinsed out with a gentle water spray at the in...

Страница 11: ...was condensation which is normal TROUBLESHOOTING Nothing Is Working but the Electronic Control Displays Digits or a Code 1 Identify the analyser code that the electronic control displays and refer to the section Service Analyser Codes 2 If the electronic control displays digits make sure that the electronic control is programmed correctly refer to the section Operation of your Pool Heat Pump and r...

Страница 12: ...s free of debris and leaves 3 If the evaporator is dusty or dirty clean it with a light spray of water and allow it to dry do not use high pressure it may damage the evaporator fins 4 When the unit is dry you may switch it back ON from the circuit breaker 5 Ensure that the clearances around the unit are respected 6 When the unit has been switched ON ensure the fan motor is working fan blades will ...

Страница 13: ...s coming from the pool heat pump and not from other equipment which will not be covered by the warranty e g noise coming from the bypass valve pool pump etc 3 An improper installation may cause this situation it will need to be corrected by the owner This situation is not covered by the warranty The Temperature Shown on the Pool Heat Pump Is Not the Same than the Pool Thermometer It is possible to...

Страница 14: ...ure the pool pump is switched ON Press ON OFF to restart the pool heat pump On new installations ensure the installation instructions were respected Check that the pool water level is correct that the pool pump is filled with water to the rim and that water is flowing correctly through the pool pump to the pool heat pump Check swimming pool and pool pump skimmer baskets and the drain at the bottom...

Страница 15: ...ics and reversible XLR electronic control with diagnostics Problem Action Remedy Problem Low refrigerant level in the pool heat pump or the low pressure safety control is defective Atmospheric conditions as well as the pool water temperature should not be below the minimum operating temperatures as stated below in order to obtain efficiency and avoid codes from appearing on the electronic control ...

Страница 16: ...tion stated in this section Warranty will only cover manufacturing defects All service call requests which are not of this nature must be paid by the purchaser to the service company authorized by Waterco Warranty service is to be completed by an authorized Service Center authorized by Waterco Where applicable in home service will be made available only in areas where a contracted service provider...