background image

 

 

 

 

 

 

 

 

 

 

 

 

INSTALLATION INSTRUCTIONS 

Water Piping 

 

The  following  piping  sequence  must  be  followed  without  exception:  1-pool  pump  2-filter  3-
pool heat pump 4-chlorinator (when installed).  Rigid PVC piping is recommended, all joints 
should  be  glued  with  PVC  glue.    If  rigid  PVC  is  not  available,  you  can  use  soft  or  flexible 
piping with stainless steel clamps.  When the piping installation is complete, operate the pool 
pump  and  check  the  system  for  leaks.    Then  check  the  filter  pressure  gauge  to  see  that 
excessive pump head pressure is not indicated.  NOTE: Units are designed to operate with a 
minimum water circulation of 132 LPM/35 GPM. 
 

NOTE: A bypass kit is strongly recommended and should be installed for adjustment 
of water flow and ease of service. 

Hook up 

Pool Heat Pump

 

| Pg 08

 

 

 

INSTALLATION INSTRUCTIONS 

 

 

    

  

IMPORTANT 

Electrical 

 

To  ensure  your  safety  and  ensure  the  adequate  functioning  of  your  pool  heat  pump, 

all 

electrical  work  should  be  performed  by  a  fully  qualified  and  licensed  electrician  in 

accordance with local electrical codes.

 

 

An adequate circuit breaker and copper wiring must be used.  This information is available on 

the  name  plate  of  the  pool  heat  pump.    It  may  be  necessary  to  install  a  ground  circuit 

breaker. 

 

 

 

 

          IMPORTANT 

Plumbing  connections 
to  the  pool  heat  pump 
must  be  made  by  hand 
only,  as  it  may  break 
the water Inlet or Outlet 
connections. 
 

1.  Either a 1/3 pound check valve or a loop 

MUST

 be installed between the pool heat pump 

and any automatic chlorinator to prevent highly chlorine concentrated water from flowing 
back to the pool heat pump when the pool pump is not running. 
 

2.  Units  that  are  located  below  the  water  level  of  the  swimming  pool  may  require  the 

pressure switch to be adjusted. 
This can be checked by the following method: 

-

 

Switch 

ON

 the water pump and the pool heat pump 

-

 

While the pool heat pump is running, switch 

OFF

 the water pump.  

 
If the pool heat pump shuts down automatically no further action is required.   

 
If the pool heat pump continues to run, you will need to have a qualified technician adjust the 
water pressure switch (not under warranty).  For further information, please contact Waterco. 

 

 
 

 

: 208/240 v - 60Hz-1 phase 

: 208/240 v - 50Hz-1 phase 

: 200/230 v - 50/60 Hz - 3 phase 

: 380/420 v - 50/60 Hz - 3 phase 

 

 

WARNING

 

 

Plumbing Diagram 

 
 

3 Way Valve 

From Spa  From Pool 

Electrical Connection 

 

Standard 60 Hz power supply 

Standard 50 Hz power supply  

3 phase power supply  

           

   

 

 

 

Breaker Size

 

 

Please consult the name plate on the base or the side of your pool heat pump for running 

amperage and required breaker size. 

 

 

Electrical Wire Size

 

 
Please consult a qualified and licensed electrician. 

 
  
 

 

 

 
The power cable ground must be connected to the electrical panel and to the ground 
lug of the pool heat pump.  An improper installation may be a potential cause of fire, 
electrical shock or injury.

 

 

Water In 

Water By-pass 

To Spa 

Water in   Drain  Water Out 

PUMP 

POOL HEAT PUMP 

Water Out 

 

 

Filter 

Chlorinator 
or Chlorine 
Generator 

Check Valve 

Vertical Trap 

SPA      POOL 

MultiCyclone 

To Pool 

SPA       POOL 

Содержание Ultra

Страница 1: ...t Une installation inadéquate annulera la garantie Notice to Installer Avis à l installateur This manual contains important information about the installation operation and safe use of this product Once the product has been installed this manual must be given to the owner operator of this equipment Ce manuel contient des informations importantes sur l installation l exploitation et l utilisation s...

Страница 2: ...___ Compressor Starts and Stops ____________ There Is Water Around the Pool Heat Pump _ Pool Heat Pump Has Ice Formed On the Evaporator Coil _________________ Pool Heat Pump Is Not Heating ___________ Analysis Chart ________________________ Circuit Breaker Trips ___________________ Pool Heat Pump Is Noisy ________________ The Temperature Shown on Pool Heat Pump Is Not the Same than the Pool Thermo...

Страница 3: ...ded for proper operation and heating Please refer to the section Location on the following page IMPORTANT Usage of Chemical Products Never add liquid chlorine granular chlorine or slow dissolving tablets pucks into the skimmer basket This high concentration of chemicals should be avoided Water quality standards that must be strictly adhered to Warranty can be voided if not maintained within these ...

Страница 4: ...ir is pulled through the evaporator coil and discharged through the top or front grill Clearances should be allowed in front and around the unit for unrestricted air discharge and service access See Figure 1 and Figure 2 Re circulation of cold discharged air back into the evaporator coil will greatly reduce the unit s heating capacity and efficiency Pool Heat Pump Pg 06 No obstruction above Pool H...

Страница 5: ... MUST be installed between the pool heat pump and any automatic chlorinator to prevent highly chlorine concentrated water from flowing back to the pool heat pump when the pool pump is not running 2 Units that are located below the water level of the swimming pool may require the pressure switch to be adjusted This can be checked by the following method Switch ON the water pump and the pool heat pu...

Страница 6: ... these systems may leak stray voltage and currents into the water causing severe electrolysis This dramatically shortens the life of the pool heat pump and will void the warranty NOTE Bonding to pool pump is not required for above ground pool pumps but all other equipment must be bonded Pool water temperature must be above Atmospheric conditions must be above Model Ultra Reversible XLR All others ...

Страница 7: ...g back to the pool water temperature when all keys remain untouched for 5 seconds To change the temperature display from Fahrenheit F to Celsius C press the button C F The led below the F or C will be lit to indicate the current selection Note The pool heat pump will stop working when the programmed temperature is reached OPERATION OF YOUR POOL HEAT PUMP Pool Solar Blanket A pool solar blanket sho...

Страница 8: ...e XLR Electronic Control with Diagnostics Functioning of your Electronic Control with Diagnostics and Reversible XLR Electronic Control with Diagnostics OPERATION OF YOUR POOL HEAT PUMP Temperature Calibration It is possible to have a temperature variation between the water in the swimming pool and the reading of the pool heat pump temperature probe sensor Example the water in the pool is 26 ºC 80...

Страница 9: ... 70 F 21 C please adjust the bypass valve as shown Approx 60 of the water is circulating in the unit When the pool water temperature is between 70 F 21 C and 78 F 26 C please adjust the bypass valve as shown Approx 80 of the water is circulating in the unit When the pool water temperature is above 79 F 26 C please close the bypass valve as shown 100 of the water is circulating in the unit IMPORTAN...

Страница 10: ...the pool heat pump s heat exchanger in preparation for winter 4 Once the piping is disconnected the pool heat pump s heat exchanger MUST be emptied the use of a water vacuum cleaner is strongly recommended or if you do not have this tool you can tilt the unit 75 until all the water is out 5 It is recommended that the pool heat pump s heat exchanger is rinsed out with a gentle water spray at the in...

Страница 11: ...was condensation which is normal TROUBLESHOOTING Nothing Is Working but the Electronic Control Displays Digits or a Code 1 Identify the analyser code that the electronic control displays and refer to the section Service Analyser Codes 2 If the electronic control displays digits make sure that the electronic control is programmed correctly refer to the section Operation of your Pool Heat Pump and r...

Страница 12: ...s free of debris and leaves 3 If the evaporator is dusty or dirty clean it with a light spray of water and allow it to dry do not use high pressure it may damage the evaporator fins 4 When the unit is dry you may switch it back ON from the circuit breaker 5 Ensure that the clearances around the unit are respected 6 When the unit has been switched ON ensure the fan motor is working fan blades will ...

Страница 13: ...s coming from the pool heat pump and not from other equipment which will not be covered by the warranty e g noise coming from the bypass valve pool pump etc 3 An improper installation may cause this situation it will need to be corrected by the owner This situation is not covered by the warranty The Temperature Shown on the Pool Heat Pump Is Not the Same than the Pool Thermometer It is possible to...

Страница 14: ...ure the pool pump is switched ON Press ON OFF to restart the pool heat pump On new installations ensure the installation instructions were respected Check that the pool water level is correct that the pool pump is filled with water to the rim and that water is flowing correctly through the pool pump to the pool heat pump Check swimming pool and pool pump skimmer baskets and the drain at the bottom...

Страница 15: ...ics and reversible XLR electronic control with diagnostics Problem Action Remedy Problem Low refrigerant level in the pool heat pump or the low pressure safety control is defective Atmospheric conditions as well as the pool water temperature should not be below the minimum operating temperatures as stated below in order to obtain efficiency and avoid codes from appearing on the electronic control ...

Страница 16: ...tion stated in this section Warranty will only cover manufacturing defects All service call requests which are not of this nature must be paid by the purchaser to the service company authorized by Waterco Warranty service is to be completed by an authorized Service Center authorized by Waterco Where applicable in home service will be made available only in areas where a contracted service provider...

Отзывы: