OPERATION OF YOUR POOL HEAT PUMP 

 
Initial Heating

 

 

Atmospheric  conditions  as  well  as  the  pool  water  temperature  should  not  be  below  the 
minimum  operating  temperatures,  as  stated  below,  in  order  to  obtain  efficiency  and  avoid 
codes  from  appearing  on  the  electronic  control  temperature  display.    These  codes  are  not 
generally a problem with the pool heat pump at these conditions and are not covered by the 
warranty. 
 
If temperatures are below the minimum temperatures listed, the pool heat pump should not 
be operated and must be switched off. 
 
For  Ultra  and  Reversible  (XLR)  units,  they  will  automatically  stop  without  human 
intervention. 
 

 

INSTALLATION INSTRUCTIONS 

Bonding 

 

 
Because  all  metals  have  different  electrical  potentials,  ALL  metal  and  electrical 
components  of  the  pool  system  MUST  be  bonded  together.

    This  includes  the  metal 

framework  of  the  pool,  the  light,  the  pump,  the  filter  (if  metal),  the  pool  heat  pump,  any 
automatic  chlorine  generator  and  any  other  metal  or  electrical  equipment  bonded  to  your 
pool. 

 
On some older pools, this substructure bond wire may not exist.  In these cases, a 3 - 4 foot 
solid  copper  rod  must  be  driven  into  the  ground  near  equipment;  all  electric  and  metal 
components must be bonded to each other and to the copper rod.  Warranty will be voided if 
system is not properly bonded. 
 

CAUTION: It is recommended when using automatic chlorinators, to ensure that they 
are properly installed and bonded.  Some of these systems may leak stray voltage and 
currents  into  the  water  causing  severe  electrolysis.    This  dramatically  shortens  the 
life of the pool heat pump and will void the warranty. 
 

NOTE:  Bonding  to  pool  pump  is  not  required  for  above  ground  pool  pumps  but  all 
other equipment must be bonded.

 

 

Pool water temperature

 

must be above

 

Atmospheric conditions

 

must be above

 

Model

 

Ultra 

Reversible (XLR) 

All others 

 

Bonding Diagram 
 

 

Pool House 
Breaker Box 

 
 

 

32 °F (0 °C) 
43 °F (6 °C) 

52 °F (11 °C) 

 

50 °F (10 °C) 
65 °F (18 °C) 
65 °F (18 °C)

 

The speed of heating is dependent of five basic factors: 

1.  Size of the pool. 

2.  How many degrees the water is to be heated. 

3.  Ambient air temperature - the warmer the air, the less time required to heat. 

4.  Use of a solar blanket. 

5.  The size of the pool heat pump. 

 

To achieve initial heating, your pool heat pump and the pool pump may work up to 24 hours 

per day until desired temperature is achieved.  The initial heating time may vary depending 

of the above five factors.   After initial heating, operating time may be reduced to match daily 

heat loss. 

 

Pool Heat Pump Running Time 

 

Most units should be sized to operate during the pool filtering cycle time of 8-12 hours daily, 

providing an even, steady flow of warm water.  On warmer days, the pool heat pump will run 

less because the heat loss will be less.  Pool heat pumps are able to operate 24 hours per 

day when necessary. 

 

 

 

If  Pool  Bonding  Wire  does  not 
exist, 

then a 3’ to 4’ Copper Rod 

must  be  driven  into  the  ground 

and equipment bonded to it. 

Bonding Wires 

Chlorine 
Generator 

Power Supply 
and Grounding 
Wires Conduits

 

Pool Heat Pump 

Pool Pump 

Light 

Need bounding if 
it is a metal filter 

Pool Bonding Wire 

Содержание Ultra

Страница 1: ...t Une installation inadéquate annulera la garantie Notice to Installer Avis à l installateur This manual contains important information about the installation operation and safe use of this product Once the product has been installed this manual must be given to the owner operator of this equipment Ce manuel contient des informations importantes sur l installation l exploitation et l utilisation s...

Страница 2: ...___ Compressor Starts and Stops ____________ There Is Water Around the Pool Heat Pump _ Pool Heat Pump Has Ice Formed On the Evaporator Coil _________________ Pool Heat Pump Is Not Heating ___________ Analysis Chart ________________________ Circuit Breaker Trips ___________________ Pool Heat Pump Is Noisy ________________ The Temperature Shown on Pool Heat Pump Is Not the Same than the Pool Thermo...

Страница 3: ...ded for proper operation and heating Please refer to the section Location on the following page IMPORTANT Usage of Chemical Products Never add liquid chlorine granular chlorine or slow dissolving tablets pucks into the skimmer basket This high concentration of chemicals should be avoided Water quality standards that must be strictly adhered to Warranty can be voided if not maintained within these ...

Страница 4: ...ir is pulled through the evaporator coil and discharged through the top or front grill Clearances should be allowed in front and around the unit for unrestricted air discharge and service access See Figure 1 and Figure 2 Re circulation of cold discharged air back into the evaporator coil will greatly reduce the unit s heating capacity and efficiency Pool Heat Pump Pg 06 No obstruction above Pool H...

Страница 5: ... MUST be installed between the pool heat pump and any automatic chlorinator to prevent highly chlorine concentrated water from flowing back to the pool heat pump when the pool pump is not running 2 Units that are located below the water level of the swimming pool may require the pressure switch to be adjusted This can be checked by the following method Switch ON the water pump and the pool heat pu...

Страница 6: ... these systems may leak stray voltage and currents into the water causing severe electrolysis This dramatically shortens the life of the pool heat pump and will void the warranty NOTE Bonding to pool pump is not required for above ground pool pumps but all other equipment must be bonded Pool water temperature must be above Atmospheric conditions must be above Model Ultra Reversible XLR All others ...

Страница 7: ...g back to the pool water temperature when all keys remain untouched for 5 seconds To change the temperature display from Fahrenheit F to Celsius C press the button C F The led below the F or C will be lit to indicate the current selection Note The pool heat pump will stop working when the programmed temperature is reached OPERATION OF YOUR POOL HEAT PUMP Pool Solar Blanket A pool solar blanket sho...

Страница 8: ...e XLR Electronic Control with Diagnostics Functioning of your Electronic Control with Diagnostics and Reversible XLR Electronic Control with Diagnostics OPERATION OF YOUR POOL HEAT PUMP Temperature Calibration It is possible to have a temperature variation between the water in the swimming pool and the reading of the pool heat pump temperature probe sensor Example the water in the pool is 26 ºC 80...

Страница 9: ... 70 F 21 C please adjust the bypass valve as shown Approx 60 of the water is circulating in the unit When the pool water temperature is between 70 F 21 C and 78 F 26 C please adjust the bypass valve as shown Approx 80 of the water is circulating in the unit When the pool water temperature is above 79 F 26 C please close the bypass valve as shown 100 of the water is circulating in the unit IMPORTAN...

Страница 10: ...the pool heat pump s heat exchanger in preparation for winter 4 Once the piping is disconnected the pool heat pump s heat exchanger MUST be emptied the use of a water vacuum cleaner is strongly recommended or if you do not have this tool you can tilt the unit 75 until all the water is out 5 It is recommended that the pool heat pump s heat exchanger is rinsed out with a gentle water spray at the in...

Страница 11: ...was condensation which is normal TROUBLESHOOTING Nothing Is Working but the Electronic Control Displays Digits or a Code 1 Identify the analyser code that the electronic control displays and refer to the section Service Analyser Codes 2 If the electronic control displays digits make sure that the electronic control is programmed correctly refer to the section Operation of your Pool Heat Pump and r...

Страница 12: ...s free of debris and leaves 3 If the evaporator is dusty or dirty clean it with a light spray of water and allow it to dry do not use high pressure it may damage the evaporator fins 4 When the unit is dry you may switch it back ON from the circuit breaker 5 Ensure that the clearances around the unit are respected 6 When the unit has been switched ON ensure the fan motor is working fan blades will ...

Страница 13: ...s coming from the pool heat pump and not from other equipment which will not be covered by the warranty e g noise coming from the bypass valve pool pump etc 3 An improper installation may cause this situation it will need to be corrected by the owner This situation is not covered by the warranty The Temperature Shown on the Pool Heat Pump Is Not the Same than the Pool Thermometer It is possible to...

Страница 14: ...ure the pool pump is switched ON Press ON OFF to restart the pool heat pump On new installations ensure the installation instructions were respected Check that the pool water level is correct that the pool pump is filled with water to the rim and that water is flowing correctly through the pool pump to the pool heat pump Check swimming pool and pool pump skimmer baskets and the drain at the bottom...

Страница 15: ...ics and reversible XLR electronic control with diagnostics Problem Action Remedy Problem Low refrigerant level in the pool heat pump or the low pressure safety control is defective Atmospheric conditions as well as the pool water temperature should not be below the minimum operating temperatures as stated below in order to obtain efficiency and avoid codes from appearing on the electronic control ...

Страница 16: ...tion stated in this section Warranty will only cover manufacturing defects All service call requests which are not of this nature must be paid by the purchaser to the service company authorized by Waterco Warranty service is to be completed by an authorized Service Center authorized by Waterco Where applicable in home service will be made available only in areas where a contracted service provider...

Отзывы: