background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pool Heat Pump

 

| Pg 20

 

 

TROUBLESHOOTING 

Fan Blades Turn, but Compressor Is Not Functioning 

 
The  pool  heat  pump  has  a  built  in  delay  timer  which  prevents  the  compressor  from  starting 
immediately.    The  delay  can  be  3  to  5  minutes  in  duration  after  the  fan  blades  have  turned.  
Furthermore, if the unit is in defrost mode, the compressor will not start for 3 to 20 minutes. 
 
 
 
 
 
 
 
 
 
 
 
 

 

Compressor Starts and Stops 

 
1. 

Check  that  the  unit  has  been  installed  correctly.    Refer  to  section  “Installation 
Procedures”. 

2. 

Check that the water inlet and outlet of the unit have been connected correctly. 

 

 

There Is Water Around the Pool Heat Pump 

 
It is a normal occurrence for water condensation to be seen running from the unit base.  There 
will be on average 1 to 1.5 gallons (4 to 6 litres) of condensed water per hour being discharged 
from  the  unit  base.    In  order  to  avoid  water  accumulation,  you  may  use  decorative  rocks 
around  the  concrete slab  or  a  basin under  the  unit.   Be  sure that clearances  around  the  unit 
are respected. 
 
To test the unit and confirm you have no pool water leaking from the unit, perform the following 
test which is best performed early in the morning and continued for the whole day: 
 

1. 

Turn 

OFF

 the pool heat pump from the circuit breaker and the pool pump. 

2. 

Open the bypass valve. 

3. 

Close the 

IN

 and 

OUT

 water valves on the unit. 

4. 

Restart the pool pump. The pool heat pump 

MUST

 remain 

OFF

5. 

When  all  of the  water  around  the  base  of  the  pool  heat  pump  has dried,  open  the         

water 

IN

 and water 

OUT

 valves on the pool heat pump. 

6. 

Close the bypass valve to allow full water flow through the pool heat pump. 

 
If  water  is  now  seen  running  from  the  outside  of  the  pool  heat  pump  or  inside  the  pool  heat 
pump after a short period of time, you should call for service.  If no water is seen after a short 
period of time, it would be assumed the water was condensation which is normal. 
 
 

 

 

TROUBLESHOOTING 

Nothing  Is  Working  but  the  Electronic  Control  Displays 
Digits or a Code

 

1.  Identify  the  analyser  code  that  the  electronic  control  displays  and  refer  to  the  section 

“Service Analyser Codes”; 

 
2.  If  the  electronic  control  displays  digits,  make  sure  that  the  electronic  control  is 

programmed  correct

ly,  refer  to  the  section  “Operation  of  your  Pool  Heat  Pump”  and 

reprogram if necessary. 

 

**Note  that  this  situation  could  occur  when  the  electrical  voltage,  as  stated  on  the 
pool  heat  pump  name  plate,  is  not  respected.    This  situation  is  not  covered  by  the 
manufacturer warranty.

 

 

 

 

1.  Check that air being discharged from the fan blades is colder than the ambient air.  If the 

air  being  discharged  by  the  fan  blades  is  colder,  it  means  that  the  compressor  is 
functioning correctly. 

 
2.  Turn 

OFF

 the pool heat pump, then immediately turn it back 

ON

 
3.  As soon as the fan blades start turning, wait a minimum of 3-5 minutes. The compressor 

should start up after this time and you will be able to identify a different sound made by 
the compressor when it starts; 

 
4.  If  the  compressor  is  functioning,  but  shuts  off  immediately,  consult  the  section 

“Compressor Starts and Stops”. 

 

 

 

If you made the purchase of an automation system (or another equipment not included with 
the Waterco  pool  heat  pump),  make sure  that  the  equipment was  properly  installed.   If  the 
problem is the installation of the other equipment, Waterco warranty will not apply and you 
will pay the service call fees. 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 

 

 

 

 

 

Fan Doesn’t Work (the Fan Blades Are Not Moving) 

 

1. 

IMPORTANT: For safety

, switch 

OFF

 the circuit-breaker; 

2.  Try to rotate the fan blades of the fan with a rod to see if the motor is jammed or seized; 

3.  If the fan blades do not turn freely, leave the unit switched 

OFF

 and call for service; 

4.  If the fan blades turn freely, switch 

ON

 the circuit breaker and the pool heat pump again. 

 
** Note that your fan motor may have an electrical fault if the blades turn freely when the unit is 
switched 

OFF

 and does not start when the unit is switched 

ON

 

Содержание Ultra

Страница 1: ...t Une installation inadéquate annulera la garantie Notice to Installer Avis à l installateur This manual contains important information about the installation operation and safe use of this product Once the product has been installed this manual must be given to the owner operator of this equipment Ce manuel contient des informations importantes sur l installation l exploitation et l utilisation s...

Страница 2: ...___ Compressor Starts and Stops ____________ There Is Water Around the Pool Heat Pump _ Pool Heat Pump Has Ice Formed On the Evaporator Coil _________________ Pool Heat Pump Is Not Heating ___________ Analysis Chart ________________________ Circuit Breaker Trips ___________________ Pool Heat Pump Is Noisy ________________ The Temperature Shown on Pool Heat Pump Is Not the Same than the Pool Thermo...

Страница 3: ...ded for proper operation and heating Please refer to the section Location on the following page IMPORTANT Usage of Chemical Products Never add liquid chlorine granular chlorine or slow dissolving tablets pucks into the skimmer basket This high concentration of chemicals should be avoided Water quality standards that must be strictly adhered to Warranty can be voided if not maintained within these ...

Страница 4: ...ir is pulled through the evaporator coil and discharged through the top or front grill Clearances should be allowed in front and around the unit for unrestricted air discharge and service access See Figure 1 and Figure 2 Re circulation of cold discharged air back into the evaporator coil will greatly reduce the unit s heating capacity and efficiency Pool Heat Pump Pg 06 No obstruction above Pool H...

Страница 5: ... MUST be installed between the pool heat pump and any automatic chlorinator to prevent highly chlorine concentrated water from flowing back to the pool heat pump when the pool pump is not running 2 Units that are located below the water level of the swimming pool may require the pressure switch to be adjusted This can be checked by the following method Switch ON the water pump and the pool heat pu...

Страница 6: ... these systems may leak stray voltage and currents into the water causing severe electrolysis This dramatically shortens the life of the pool heat pump and will void the warranty NOTE Bonding to pool pump is not required for above ground pool pumps but all other equipment must be bonded Pool water temperature must be above Atmospheric conditions must be above Model Ultra Reversible XLR All others ...

Страница 7: ...g back to the pool water temperature when all keys remain untouched for 5 seconds To change the temperature display from Fahrenheit F to Celsius C press the button C F The led below the F or C will be lit to indicate the current selection Note The pool heat pump will stop working when the programmed temperature is reached OPERATION OF YOUR POOL HEAT PUMP Pool Solar Blanket A pool solar blanket sho...

Страница 8: ...e XLR Electronic Control with Diagnostics Functioning of your Electronic Control with Diagnostics and Reversible XLR Electronic Control with Diagnostics OPERATION OF YOUR POOL HEAT PUMP Temperature Calibration It is possible to have a temperature variation between the water in the swimming pool and the reading of the pool heat pump temperature probe sensor Example the water in the pool is 26 ºC 80...

Страница 9: ... 70 F 21 C please adjust the bypass valve as shown Approx 60 of the water is circulating in the unit When the pool water temperature is between 70 F 21 C and 78 F 26 C please adjust the bypass valve as shown Approx 80 of the water is circulating in the unit When the pool water temperature is above 79 F 26 C please close the bypass valve as shown 100 of the water is circulating in the unit IMPORTAN...

Страница 10: ...the pool heat pump s heat exchanger in preparation for winter 4 Once the piping is disconnected the pool heat pump s heat exchanger MUST be emptied the use of a water vacuum cleaner is strongly recommended or if you do not have this tool you can tilt the unit 75 until all the water is out 5 It is recommended that the pool heat pump s heat exchanger is rinsed out with a gentle water spray at the in...

Страница 11: ...was condensation which is normal TROUBLESHOOTING Nothing Is Working but the Electronic Control Displays Digits or a Code 1 Identify the analyser code that the electronic control displays and refer to the section Service Analyser Codes 2 If the electronic control displays digits make sure that the electronic control is programmed correctly refer to the section Operation of your Pool Heat Pump and r...

Страница 12: ...s free of debris and leaves 3 If the evaporator is dusty or dirty clean it with a light spray of water and allow it to dry do not use high pressure it may damage the evaporator fins 4 When the unit is dry you may switch it back ON from the circuit breaker 5 Ensure that the clearances around the unit are respected 6 When the unit has been switched ON ensure the fan motor is working fan blades will ...

Страница 13: ...s coming from the pool heat pump and not from other equipment which will not be covered by the warranty e g noise coming from the bypass valve pool pump etc 3 An improper installation may cause this situation it will need to be corrected by the owner This situation is not covered by the warranty The Temperature Shown on the Pool Heat Pump Is Not the Same than the Pool Thermometer It is possible to...

Страница 14: ...ure the pool pump is switched ON Press ON OFF to restart the pool heat pump On new installations ensure the installation instructions were respected Check that the pool water level is correct that the pool pump is filled with water to the rim and that water is flowing correctly through the pool pump to the pool heat pump Check swimming pool and pool pump skimmer baskets and the drain at the bottom...

Страница 15: ...ics and reversible XLR electronic control with diagnostics Problem Action Remedy Problem Low refrigerant level in the pool heat pump or the low pressure safety control is defective Atmospheric conditions as well as the pool water temperature should not be below the minimum operating temperatures as stated below in order to obtain efficiency and avoid codes from appearing on the electronic control ...

Страница 16: ...tion stated in this section Warranty will only cover manufacturing defects All service call requests which are not of this nature must be paid by the purchaser to the service company authorized by Waterco Warranty service is to be completed by an authorized Service Center authorized by Waterco Where applicable in home service will be made available only in areas where a contracted service provider...