background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 

 

 
 
 

 

WATERCO POOL HEAT PUMP

 

WATERCO THERMOPOMPE CHAUFFE-PISCINE

 

User and 
Care Guide Manual 
 
Guide d’utilisation 
et d’entretien 

 
 

 

 

 

 

 
 
  

AUSTRALIA 

NSW - Sydney (HEAD OFFICE) 
Tel: +61 2 9898 8686 

 
VIC/ TAS - Melbourne 
Tel: +61 3 9764 1211 

 
WA - Perth 
Tel: +61 8 9273 1900 

 
QLD 

– Brisbane 

Tel: +61 7 3299 9900 

 
SA/ NT - Adelaide 
Tel: +61 8 8244 6000 
 

CANADA / NORTH-EAST USA 

Waterco Canada Inc 
Quebec, Canada 
Tel: 1 888 796 6002 
 

USA 

Waterco USA Inc 
Augusta, USA 
Tel: +17067937291 
        +18002477291 

 

 
 
 
 

This  equipment  must  be  installed  and  serviced  by  a  qualified  technician.    Improper 
installation  can  create  electrical  hazards  which  could  result  in  property  damage, 
serious injury or death.  

Improper installation will void the warranty.

  

Cet  équipement  doit  être  installé  et  réparé  par  un  technicien  qualifié.    Une  mauvaise 
installation  peut  entraîner  des  risques  électriques  qui  pourraient  provoquer  des 
dommages, des blessures graves ou la mort.  

Une installation inadéquate annulera 

la garantie.  

 

Notice to Installer / 

Avis à l’installateur 

This  manual  contains  important  information  about  the  installation,  operation  and  safe 
use of this product.  Once the product has been installed, 

this manual must be given 

to the owner/operator of this equipment.

  

 
Ce  manuel  contient  des  informations  importantes  sur  l’installation,  l’exploitation  et 
l’utilisation sécuritaire de ce produit. Une fois que le produit a été installé, 

ce manuel 

doit être remis à l’acheteur et/ou utilisateur de cet équipement. 
 
 
 
 
 

www.waterco.com

 

 

 
NEW ZEALAND 

Waterco (NZ) Limited 
Auckland, New Zealand 
Tel: +64 9 525 7570 
 
 

EUROPE 

Waterco (Europe) Limited 
Sittingbourne, Kent. UK 
Tel: +44(0) 1795 521 733 

 

 
CHINA 

Waterco (C) Limited 
Guangzhou, China 
Tel: +8620 3222 2180 
 
 

MALAYSIA 

Waterco (Far East) Sdn. Bhd. 
Selangor, Malaysia 
Tel: +60 3 6145 6000 

 

Website / Internet : 

www.waterco.com

  

This web site address will enable you to select the appropriate country website. 
Ce site web vous permettra de choisir le pays avec lequel vous devrez communiquer. 
 
 
 
 

Waterco Limited ABN 62 002 070 733 
 
 

(ZZM1331) 04/2012 

Содержание Ultra

Страница 1: ...t Une installation inadéquate annulera la garantie Notice to Installer Avis à l installateur This manual contains important information about the installation operation and safe use of this product Once the product has been installed this manual must be given to the owner operator of this equipment Ce manuel contient des informations importantes sur l installation l exploitation et l utilisation s...

Страница 2: ...___ Compressor Starts and Stops ____________ There Is Water Around the Pool Heat Pump _ Pool Heat Pump Has Ice Formed On the Evaporator Coil _________________ Pool Heat Pump Is Not Heating ___________ Analysis Chart ________________________ Circuit Breaker Trips ___________________ Pool Heat Pump Is Noisy ________________ The Temperature Shown on Pool Heat Pump Is Not the Same than the Pool Thermo...

Страница 3: ...ded for proper operation and heating Please refer to the section Location on the following page IMPORTANT Usage of Chemical Products Never add liquid chlorine granular chlorine or slow dissolving tablets pucks into the skimmer basket This high concentration of chemicals should be avoided Water quality standards that must be strictly adhered to Warranty can be voided if not maintained within these ...

Страница 4: ...ir is pulled through the evaporator coil and discharged through the top or front grill Clearances should be allowed in front and around the unit for unrestricted air discharge and service access See Figure 1 and Figure 2 Re circulation of cold discharged air back into the evaporator coil will greatly reduce the unit s heating capacity and efficiency Pool Heat Pump Pg 06 No obstruction above Pool H...

Страница 5: ... MUST be installed between the pool heat pump and any automatic chlorinator to prevent highly chlorine concentrated water from flowing back to the pool heat pump when the pool pump is not running 2 Units that are located below the water level of the swimming pool may require the pressure switch to be adjusted This can be checked by the following method Switch ON the water pump and the pool heat pu...

Страница 6: ... these systems may leak stray voltage and currents into the water causing severe electrolysis This dramatically shortens the life of the pool heat pump and will void the warranty NOTE Bonding to pool pump is not required for above ground pool pumps but all other equipment must be bonded Pool water temperature must be above Atmospheric conditions must be above Model Ultra Reversible XLR All others ...

Страница 7: ...g back to the pool water temperature when all keys remain untouched for 5 seconds To change the temperature display from Fahrenheit F to Celsius C press the button C F The led below the F or C will be lit to indicate the current selection Note The pool heat pump will stop working when the programmed temperature is reached OPERATION OF YOUR POOL HEAT PUMP Pool Solar Blanket A pool solar blanket sho...

Страница 8: ...e XLR Electronic Control with Diagnostics Functioning of your Electronic Control with Diagnostics and Reversible XLR Electronic Control with Diagnostics OPERATION OF YOUR POOL HEAT PUMP Temperature Calibration It is possible to have a temperature variation between the water in the swimming pool and the reading of the pool heat pump temperature probe sensor Example the water in the pool is 26 ºC 80...

Страница 9: ... 70 F 21 C please adjust the bypass valve as shown Approx 60 of the water is circulating in the unit When the pool water temperature is between 70 F 21 C and 78 F 26 C please adjust the bypass valve as shown Approx 80 of the water is circulating in the unit When the pool water temperature is above 79 F 26 C please close the bypass valve as shown 100 of the water is circulating in the unit IMPORTAN...

Страница 10: ...the pool heat pump s heat exchanger in preparation for winter 4 Once the piping is disconnected the pool heat pump s heat exchanger MUST be emptied the use of a water vacuum cleaner is strongly recommended or if you do not have this tool you can tilt the unit 75 until all the water is out 5 It is recommended that the pool heat pump s heat exchanger is rinsed out with a gentle water spray at the in...

Страница 11: ...was condensation which is normal TROUBLESHOOTING Nothing Is Working but the Electronic Control Displays Digits or a Code 1 Identify the analyser code that the electronic control displays and refer to the section Service Analyser Codes 2 If the electronic control displays digits make sure that the electronic control is programmed correctly refer to the section Operation of your Pool Heat Pump and r...

Страница 12: ...s free of debris and leaves 3 If the evaporator is dusty or dirty clean it with a light spray of water and allow it to dry do not use high pressure it may damage the evaporator fins 4 When the unit is dry you may switch it back ON from the circuit breaker 5 Ensure that the clearances around the unit are respected 6 When the unit has been switched ON ensure the fan motor is working fan blades will ...

Страница 13: ...s coming from the pool heat pump and not from other equipment which will not be covered by the warranty e g noise coming from the bypass valve pool pump etc 3 An improper installation may cause this situation it will need to be corrected by the owner This situation is not covered by the warranty The Temperature Shown on the Pool Heat Pump Is Not the Same than the Pool Thermometer It is possible to...

Страница 14: ...ure the pool pump is switched ON Press ON OFF to restart the pool heat pump On new installations ensure the installation instructions were respected Check that the pool water level is correct that the pool pump is filled with water to the rim and that water is flowing correctly through the pool pump to the pool heat pump Check swimming pool and pool pump skimmer baskets and the drain at the bottom...

Страница 15: ...ics and reversible XLR electronic control with diagnostics Problem Action Remedy Problem Low refrigerant level in the pool heat pump or the low pressure safety control is defective Atmospheric conditions as well as the pool water temperature should not be below the minimum operating temperatures as stated below in order to obtain efficiency and avoid codes from appearing on the electronic control ...

Страница 16: ...tion stated in this section Warranty will only cover manufacturing defects All service call requests which are not of this nature must be paid by the purchaser to the service company authorized by Waterco Warranty service is to be completed by an authorized Service Center authorized by Waterco Where applicable in home service will be made available only in areas where a contracted service provider...

Отзывы: