background image

Page 2

WATERAX 

STRIKER-2/3 Owner's Manual 

 

 

04/2015   

Important Safety Instructions 

It is recommended that all information provided in this manual be carefully read and 

understood before performing any operation of or maintenance to the pump. 
The procedures listed in this manual are general operating and maintenance procedures. 

They should be taken in addition to any procedures, policies and guidelines established 

by the authority having jurisdiction or the apparatus manufacturer. Where conflicts arise, 

all parties (authority having jurisdiction, the apparatus manufacturer, and 

WATERAX

 Inc.) 

will need to be contacted to determine the best resolution.  The solution will need to 

address the safety of the operator along with the proper performance and life expectancy 

of the unit. 

Personal Safety Advisory  

READ YOUR ENGINE MANUAL FIRST! 

Before proceeding further, locate and read the engine manufacturer’s manual. It contains 

very important safety information that MUST be read, understood and followed to 

safeguard you and your equipment from harm, as well as specific information on the 

proper use and care of your engine. 
READ THIS MANUAL BEFORE OPERATING YOUR PUMP! 
The improper use of the 

WATERAX

 pump could result in serious injuries as well as 

damage to the pump. Any operator should familiarize himself with the apparatus and its 

capabilities before trying to operate the equipment in an emergency situation. Please read 

this entire manual before using your 

WATERAX

 pump and follow all Personal Safety 

Advisories.  

Warnings   

  Always wear eye and ear protection when operating the pump unit. 

  Do not operate if mentally or physically fatigued. 

  Always inspect hoses and piping to avoid burst injuries. 

  Use only pipe, hose, and fittings that are rated at or above the maximum pressure 

rating of the pump shown below, or according to what maximum pressure the system 

was designed for, whichever is lower.  

  Maximum Allowable Pressure STRIKER-2/3: 600 PSI (41 bar) 

  Maximum Allowable Pump Intake Pressure STRIKER-2/3: 150 PSI (10 bar) 

  No modifications and/or alterations may be made to the pump. Any such modifications 

not only void the pump warranty but can make the unit dangerous to anyone operating 

the pump. 

  Do not operate the pump higher than the maximum rated pressure. Always run the unit 

at the lowest pressure required for the application to enhance operator and equipment 

safety.  

  Slowly close valves and use slow close valves wherever possible to prevent danger to 

other line operators and to prevent water hammer which could damage the pump and 

its piping components. 

  Relieve all system pressure before doing any service work on the pump. 

  Never run the pump in a closed or confined area. Exhaust gas contains carbon 

monoxide which is poisonous to humans. Avoid inhalation of exhaust gas.  

  Refuel engine with care. Gasoline and diesel are flammable, and gasoline vapor can 

explode. Refuel in a well-ventilated area, with the engine stopped.  

  Be alert and never touch any part of the engine exhaust system (muffler, shield, 

header pipes, etc.) while the engine is running. Always allow enough time, after 

stopping the unit, for proper cooling of the muffler and surrounding parts.  

Содержание STRIKER-II Series

Страница 1: ...STRIKER II AND STRIKER 3 Owner s Manual Publication Date 04 2015 Publication Number 701223 Rev 2...

Страница 2: ...WATERAX Inc assumes no responsibility for any omissions or errors that may appear in this document or for any damages that may result from the use of information contained herein The following are tr...

Страница 3: ...ctric Starters and Control Panels 7 Operating STRIKER 2 3 Series Pumps 8 Pre Operation Checklist 8 Flooded Suction 8 Drafting 9 Priming the Pump 10 Startup and Discharge 11 Shutdown 11 Cold Weather Op...

Страница 4: ...d follow all Personal Safety Advisories Warnings Always wear eye and ear protection when operating the pump unit Do not operate if mentally or physically fatigued Always inspect hoses and piping to av...

Страница 5: ...ual Always check for sufficient oil quantity in the engine crankcase before use see engine manual for details on checking the oil level as well as for the type of oil to use If applicable always check...

Страница 6: ...roduct guide technical notes links to the engine manufacturer s manuals news and other updates about WATERAX and its goods and services Abbreviations and Terms The following terms and abbreviations ar...

Страница 7: ...eries include Quick release clamp and swappable pump ends for minimal equipment downtime and inventory Sealed bearing to eliminate pump end greasing in the field Belt drive system for reliable low mai...

Страница 8: ...ERAX or from third party vendors for example control panels batteries and fuel lines You will also require hoses and nozzles as well as other fire apparatus plumbing which can be purchased through you...

Страница 9: ...ll as any other part of the pump or engine that is frequently accessed or inspected valves panels primers filters etc Make note of components that become hot when operating such as mufflers and engine...

Страница 10: ...that the equipment requires repair Remember that damaged equipment can expose you to safety hazards Flooded Suction Use this procedure if you are taking water from a hydrant another pump or a closed...

Страница 11: ...ump s ability to efficiently draft water The following limitations should be taken into account Water temperatures above 35 C 95 F can cause noticeable loss in pump performance Barometric pressures be...

Страница 12: ...Open the priming cap and fill pump with water manually 2 Firmly tighten priming cap 3 Pump can also be primed by jerking the suction hose until water flows from the pump s discharge port Guzzler Prim...

Страница 13: ...ge line left slightly open to allow fresh water to continue to enter the pump 3 Discharge water Once the pump is primed and with the engine running you can begin to discharge water a Slowly open the d...

Страница 14: ...ection WARNING Before doing any maintenance to the pump always ensure that the equipment cannot be accidentally started Follow any apparatus and or departmental procedures or guidelines in regards to...

Страница 15: ...e leakage is in the pump Air Trapped in Suction Pump Intake Line Check that no part of the suction hose or piping is higher than the pump intake Pump suction hose and piping must be laid out with a co...

Страница 16: ...ake hose was purchased check that they provide adequate supply to the pump to meet the performance desired If the pump was purchased used check that the actual configuration will achieve the desired p...

Страница 17: ...R 3 4 SHAFT 1 12 600151 PART 6 KEY 3 16 SQUARE S S 1 13 600124 B 7544 DRIVE CARRIER ASSEMBLY COMPLETE 1 14 800527 FAST 2 SCREW 3 8 16X1 HEX CAP ZINC DICHROMATE 4 15 600063 212 170P CLAMP ASSEMBLY ALU...

Страница 18: ...6 DRAIN HOLE TO BE FACING DOWN Figure 2 Exploded view of drive hub assembly item no 600124 Installing the Drive Assembly Before Installation Read and follow all instructions thoroughly and carefully E...

Страница 19: ...e and ensure proper alignment W DF 3 Align the non threaded holes of the bushing to the threaded holes of the driver pulley Insert the cap screws into the threaded holes of the pulley and turn them by...

Страница 20: ...nding hole on the front cover and partially insert the front cover onto the dowel pin 12 Using the top dowel pin as a pivot point swing the front cover and align the second dowel pin with the correspo...

Страница 21: ...tates the servicing of pump units and minimizes down time in the field by allowing the quick replacement of pump ends To remove pump from engine 1 Lift pump clamp lever 2 Release tension adjusting kno...

Страница 22: ...1 1 6 600380 12 12A SUCTION NOZZLE INCLUDES 12 40 1 1 7 800359 12 39 SCREW 1 4 28X9 16 SLOT FILLISTER SS 8 8 8 800360 12 38 LOCKWASHER 1 4 SPLIT SS 9 9 9 700022 A 5537 PROTECTIVE CAP FOR 2 SUCTION 1 1...

Страница 23: ...en properly installed slowly rotate shaft by hand rotary seal drive bushing should rotate with shaft 5 Attach retaining ring 16 to pump body with six screws 15 to a torque value of 22 25 in lbs 2 5 2...

Страница 24: ...e milled slot in the shaft 17 Place O ring 5 in groove of suction cover 6 Press cover into pump body until it rests on distributor 18 Install suction cover using screws 7 and lockwashers 8 Tighten scr...

Страница 25: ...d to remove the key switch from the engine and store it in a safe location if equipped with an XCP Original Engine Wiring Configuration To revert back to the Original Engine Controls refer to the inst...

Страница 26: ...Page 24 WATERAX STRIKER 2 3 Owner s Manual 24 04 2015 FastWire Wiring Diagrams WIRING FOR GASOLINE PUMPS Pins 7 8 connected on GX630 engine only...

Страница 27: ...74 38 91 mm Impeller height 12 11 1 334 1 343 in 33 88 34 11 mm Distributor vane diameter 3 740 3 770 in 95 00 95 76 mm Distributor bore 0 938 0 957 in 23 83 24 31 mm Distributor rear hub diameter 2...

Страница 28: ...Page 26 WATERAX STRIKER 2 3 Owner s Manual 26 04 2015 Notes...

Страница 29: ...Page 27 WATERAX STRIKER 2 3 Owner s Manual 04 2015 27...

Страница 30: ...Page 28 WATERAX STRIKER 2 3 Owner s Manual 28 04 2015...

Страница 31: ...ith the Seller s product manuals and supplemental instructions and guidelines as set out in full at www waterax com eng warranty d failure due to compliance with a specification or design provided or...

Страница 32: ...w changes placing 100 of our focus on manufacturing our core products portable fire pumps To do so we ve established a network of trusted supply and distribution partners that can help us provide WATE...

Отзывы: