Warranty 

 

WHEREAS 

subject to the following general and specific terms and conditions, 

WATERAX Inc. (the “

Seller”) hereby warrants to the 

original purchaser of the products from 

WATERAX, (the “

Purchaser”) that its products, including any pump parts products manufactured 

by 

WATERAX (the “

Products”) sold under Seller’s brands will be free of defects in material and workmanship for the applicable Warranty 

Period (as set out in full at www.waterax.com/eng/warranty). 

 

Product 

Warranty Period 

Coverage 

4-Stroke Powered Pumps 

Two (2) Years 

Limited 

2-Stroke Powered Pumps 

Earlier of One (1) Year or 

One hundred (100) run hours 

Limited 

Backpack Pumps 

One (1) Year 

Limited 

Skid Units 

One (1) Year 

Limited 

Control Panels, Electronics Manifolds 

One (1) Year 

Limited 

Genuine Parts 

Ninety (90) Days 

Limited 

 

1.  Limitations, exclusions and other terms and conditions applicable for all Products: 

a.   The Warranty shall be voided upon the occurrence of any of the following events: (a) the Product is used for an application, with 

products or in a manner other than the application, products and manner for which such Product is designed and intended; (b) the 

Product is subjected to a use, service, condition or environment other than a use, service, condition or environment for whic h such 

Product is designed and intended; (c) the Product is not properly installed by the Purchaser or its agent or representative; (d) the 

Product is not properly tested and maintained in accordance with Seller’s product manuals and supplemental instructions and 

guidelines, applicable industry standards and guidelines, and applicable legal and regulatory requirements; (e) the Product is 

altered, modified, serviced (with the exception of routine maintenance performed in accordance with the Seller’s product manu

als 

and supplemental instructions as set out in full at www.waterax.com/eng/warranty, and industry accepted standards and 

guidelines), or repaired by a person other than the Seller or a person authorized by the Seller to make such alteration or 

modification or perform such service or repair; (f) the Seller is not paid the full amount of the purchase price for the Product when 

due; (g) any bad faith invocation of a warranty claim or breach of a purchase agreement by the Purchaser.  

 

b.   The following are excluded from Warranty coverage: (a) non-defective parts worn, exhausted or consumed through normal usage 

of the Product; (b) any consumable parts normally subject to routine replacement, including but not limited to pump packing, O-

rings, gaskets, intake screens, anodes or filters; (c) routine maintenance as specified and in accordance with the Seller’s p

roduct 

manuals and supplemental instructions and guidelines as set out in full at www.waterax.com/eng/warranty; (d) failure due to 

compliance with a specification or design provided or required by Purchaser; (e) failure due to improper operation, excess 

pressure, excess voltage, abuse, misuse, negligence or accidents or other similar causes; (f) failure due to operator error; (g) 

damage during or after shipment and failure attributable thereto or resulting there from; (h) failure attributable to or resulting from 

the failure or substandard, inadequate or improper performance of any part, component or equipment not supplied by the Seller; 

(i) failure attributable to or resulting from the failure or substandard, inadequate or improper performance of any third party part, 

component, product or equipment, whether or not combined, packaged, incorporated, installed or used with a Seller brand part, 

component, product or equipment.  

 

2.   Claim Procedure. 

The claim procedure applicable under this warranty, including any applicable notice and documentation 

requirements, are set out in full at www.waterax.com/eng/warranty and constitute an essential term of this Warranty.  

 

3.  Repaired and Replacement Product. 

If requested to do so by the Purchaser the Seller may, at its sole option and in its  sole 

discretion, supply a replacement Product or part to the Purchaser prior to making a final determination as to whether Warranty 

Coverage is available. 

 

If the Seller ultimately determines that no Warranty Coverage is available for a Product claimed to be defective, the Purchas er shall 

have the option of either (a) having the Product returned to it freight collect without repair or replacement; or (b) if Seller determines 

that the Product is repairable, have the Product repaired by Seller or another party designated by it on a time and materials basis at 

Seller’s then current standard charges for non

-warranty repairs and then returned to Purchaser freight collect. The Seller reserves the 

right to use reconditioned parts for Warranty repairs and to use reconditioned Products for Warranty replacements. Repaired Product 

and replacement Product shall be warranted only for the remainder of the original Warranty Period.  

 

 

4.  Limitation of Liability: SELLER’S WARRANTY AS SET FORTH HEREIN IS SELLER’S SOLE AND EXCLUSIVE WARRANTY AND 

IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ALL WARRANTIES OF 

MERCHANTABILITY, QUALITY, COURSE OF DEALING, USAGE OF TRADE, FITNESS FOR A PARTICULAR PURPOSE AND 

NON-INFRINGEMENT. THE RIGHTS AND REMEDIES SET FORTH HEREIN ARE THE SOLE AND EXCLUSIVE RIGHTS AND 

REMEDIES AGAINST SELLER, EXCEPT FOR THE SPECIFIC LIABILITIES AND OBLIGATIONS PROVIDED HEREIN, SELLER 

SHALL HAVE NO LIABILITY OR OBLIGATION WITH RESPECT TO ANY PRODUCT CLAIMED TO BE DEFECTIVE IN ANY 

MANNER.

 

Содержание STRIKER-II Series

Страница 1: ...STRIKER II AND STRIKER 3 Owner s Manual Publication Date 04 2015 Publication Number 701223 Rev 2...

Страница 2: ...WATERAX Inc assumes no responsibility for any omissions or errors that may appear in this document or for any damages that may result from the use of information contained herein The following are tr...

Страница 3: ...ctric Starters and Control Panels 7 Operating STRIKER 2 3 Series Pumps 8 Pre Operation Checklist 8 Flooded Suction 8 Drafting 9 Priming the Pump 10 Startup and Discharge 11 Shutdown 11 Cold Weather Op...

Страница 4: ...d follow all Personal Safety Advisories Warnings Always wear eye and ear protection when operating the pump unit Do not operate if mentally or physically fatigued Always inspect hoses and piping to av...

Страница 5: ...ual Always check for sufficient oil quantity in the engine crankcase before use see engine manual for details on checking the oil level as well as for the type of oil to use If applicable always check...

Страница 6: ...roduct guide technical notes links to the engine manufacturer s manuals news and other updates about WATERAX and its goods and services Abbreviations and Terms The following terms and abbreviations ar...

Страница 7: ...eries include Quick release clamp and swappable pump ends for minimal equipment downtime and inventory Sealed bearing to eliminate pump end greasing in the field Belt drive system for reliable low mai...

Страница 8: ...ERAX or from third party vendors for example control panels batteries and fuel lines You will also require hoses and nozzles as well as other fire apparatus plumbing which can be purchased through you...

Страница 9: ...ll as any other part of the pump or engine that is frequently accessed or inspected valves panels primers filters etc Make note of components that become hot when operating such as mufflers and engine...

Страница 10: ...that the equipment requires repair Remember that damaged equipment can expose you to safety hazards Flooded Suction Use this procedure if you are taking water from a hydrant another pump or a closed...

Страница 11: ...ump s ability to efficiently draft water The following limitations should be taken into account Water temperatures above 35 C 95 F can cause noticeable loss in pump performance Barometric pressures be...

Страница 12: ...Open the priming cap and fill pump with water manually 2 Firmly tighten priming cap 3 Pump can also be primed by jerking the suction hose until water flows from the pump s discharge port Guzzler Prim...

Страница 13: ...ge line left slightly open to allow fresh water to continue to enter the pump 3 Discharge water Once the pump is primed and with the engine running you can begin to discharge water a Slowly open the d...

Страница 14: ...ection WARNING Before doing any maintenance to the pump always ensure that the equipment cannot be accidentally started Follow any apparatus and or departmental procedures or guidelines in regards to...

Страница 15: ...e leakage is in the pump Air Trapped in Suction Pump Intake Line Check that no part of the suction hose or piping is higher than the pump intake Pump suction hose and piping must be laid out with a co...

Страница 16: ...ake hose was purchased check that they provide adequate supply to the pump to meet the performance desired If the pump was purchased used check that the actual configuration will achieve the desired p...

Страница 17: ...R 3 4 SHAFT 1 12 600151 PART 6 KEY 3 16 SQUARE S S 1 13 600124 B 7544 DRIVE CARRIER ASSEMBLY COMPLETE 1 14 800527 FAST 2 SCREW 3 8 16X1 HEX CAP ZINC DICHROMATE 4 15 600063 212 170P CLAMP ASSEMBLY ALU...

Страница 18: ...6 DRAIN HOLE TO BE FACING DOWN Figure 2 Exploded view of drive hub assembly item no 600124 Installing the Drive Assembly Before Installation Read and follow all instructions thoroughly and carefully E...

Страница 19: ...e and ensure proper alignment W DF 3 Align the non threaded holes of the bushing to the threaded holes of the driver pulley Insert the cap screws into the threaded holes of the pulley and turn them by...

Страница 20: ...nding hole on the front cover and partially insert the front cover onto the dowel pin 12 Using the top dowel pin as a pivot point swing the front cover and align the second dowel pin with the correspo...

Страница 21: ...tates the servicing of pump units and minimizes down time in the field by allowing the quick replacement of pump ends To remove pump from engine 1 Lift pump clamp lever 2 Release tension adjusting kno...

Страница 22: ...1 1 6 600380 12 12A SUCTION NOZZLE INCLUDES 12 40 1 1 7 800359 12 39 SCREW 1 4 28X9 16 SLOT FILLISTER SS 8 8 8 800360 12 38 LOCKWASHER 1 4 SPLIT SS 9 9 9 700022 A 5537 PROTECTIVE CAP FOR 2 SUCTION 1 1...

Страница 23: ...en properly installed slowly rotate shaft by hand rotary seal drive bushing should rotate with shaft 5 Attach retaining ring 16 to pump body with six screws 15 to a torque value of 22 25 in lbs 2 5 2...

Страница 24: ...e milled slot in the shaft 17 Place O ring 5 in groove of suction cover 6 Press cover into pump body until it rests on distributor 18 Install suction cover using screws 7 and lockwashers 8 Tighten scr...

Страница 25: ...d to remove the key switch from the engine and store it in a safe location if equipped with an XCP Original Engine Wiring Configuration To revert back to the Original Engine Controls refer to the inst...

Страница 26: ...Page 24 WATERAX STRIKER 2 3 Owner s Manual 24 04 2015 FastWire Wiring Diagrams WIRING FOR GASOLINE PUMPS Pins 7 8 connected on GX630 engine only...

Страница 27: ...74 38 91 mm Impeller height 12 11 1 334 1 343 in 33 88 34 11 mm Distributor vane diameter 3 740 3 770 in 95 00 95 76 mm Distributor bore 0 938 0 957 in 23 83 24 31 mm Distributor rear hub diameter 2...

Страница 28: ...Page 26 WATERAX STRIKER 2 3 Owner s Manual 26 04 2015 Notes...

Страница 29: ...Page 27 WATERAX STRIKER 2 3 Owner s Manual 04 2015 27...

Страница 30: ...Page 28 WATERAX STRIKER 2 3 Owner s Manual 28 04 2015...

Страница 31: ...ith the Seller s product manuals and supplemental instructions and guidelines as set out in full at www waterax com eng warranty d failure due to compliance with a specification or design provided or...

Страница 32: ...w changes placing 100 of our focus on manufacturing our core products portable fire pumps To do so we ve established a network of trusted supply and distribution partners that can help us provide WATE...

Отзывы: