TYPICAL SYSTEM EXAMPLES (CONTINUED)
Multi-tank System, 3 Unit shown
System consists of 3 power heads, 2 communication cables and 3 No Hard Water Bypass (Isolation) valves
Electrical Connections:
• Each unit’s isolation valve motor wire is connected to the 2-pin connector labeled BYPASS on each unit’s PC board.
• Using two standard straight through RJ45 cables (T-568B wiring), connect the “COMM OUT” of the LEAD control
to the “COMM IN” of LAG 1 and the “COMM OUT” of LAG 1 to the “COMM IN” of LAG 2 (See Page 6 for connector
locations)
Plumbing Connections:
• To regenerate with raw/treated water, the isolation valve is piped into the outlet of each unit.
• To regenerate with soft/treated water, the isolation valve is piped into the inlet of each unit.
Visibility of the piston rod indicates
the online status of the unit.
The piston rod drive “In” or not
visible indicates the unit is offl ine,
in Standby or Regen.
LEAD
LAG 1
LAG 2