WS2H, WS2HF, and WS3 Manual
Page
63
Problem
Possible Cause
Solution
21.
# of units error:
Communications has
been broken with the
unit specifi ed in the error
message. These errors
are logged as 16K series
errors as follows:
16001: error with unit 2
16002: error with unit 3
16003: error with unit 4
16004: error with unit 5
16005: error with unit 6
16006: error with unit 7
16007: error with unit 8
16008: error with unit 9
16009: error with unit 10
160010: error with unit 11
160011: error with unit 12
160012: error with unit 13
160013: error with unit 14
160014: error with unit 15
160015: error with unit 16
a. System is programmed for the
wrong number of units or a
Slave unit is in “error # of units”
mode due to loss of power.
b. Poor connection on PC Boards
c. More than one u
nit has
determined that it is the master
control
1) Correct all errors on satellite units
before attempting to reset error on
master
a. Pressing any button while in the
# of units error will enter the user
into the setting screen. Adjust to
the correct units for the system
and press NEXT to exit the set up
screen. Press NEXT and REGEN
buttons for about 3 seconds to
resynchronize software with piston
position. Re-program valve to proper
setting.
b. Make sure wires in connector are
inserted securely and no wires are
broken. Clean pins on PC Board
by plugging and unplugging the
connector a few times to remove
excess protective coating. Press
NEXT and REGEN buttons for about
3 seconds to resynchronize software
with piston position.
c. Press NEXT
and REGEN buttons for
about 3 seconds to resynchronize
software with piston position. Then
re-program each valve to operate as
single individual unit. Re-program
the control that is to be the master
control and it will fi lter down the
programming to the slave controls
automatically.
22. Err – 18000 = Reset was
performed, this error
code will display in the
diagnostics under the
error log
a. Reset performed.
a. You can view dates and times resets
were performed
23. Err – 18001 = Power loss,
this error code will display
in the diagnostics under
error log
a. When power is lost a signal is
sent to log the power loss
a. You can view dates and times resets
were performed
24. Err – 18002 = Power
restored, this error
code will display in the
diagnostics under error
log
a. When power is restored a signal
is sent to log the power being
restored
a. You can view dates and times resets
were performed