Page 26
WS2H and WS3 Drawings and Service Manual
V3764 WS3 DLFC NPT ASY or V3764BSPT WS3 DLFC BSPT ASY
Drawing
No.
Order No.
Description
Quantity
1
V3190-090
WS1 DLFC 9.0 gpm for 1
Install One or More DLFC washers.
DLFC washers must be purchased separately.
When using one retainer and one o-ring up to
5 DLFC washers can be used for
fl
ow rates from
9 gpm up to 125 gpm.
When using two retainers and two o-rings, 5 DLFC
washers are used in one of the retainers and up to 4 more
DLFC washers can be used in the other retainer for
fl
ow
rates from 9 gpm up to 225 gpm.
V3190-100
WS1 DLFC 10.0 gpm for 1
V3190-110
WS1 DLFC 11.0 gpm for 1
V3190-130
WS1 DLFC 13.0 gpm for 1
V3190-150
WS1 DLFC 15.0 gpm for 1
V3190-170
WS1 DLFC 17.0 gpm for 1
V3190-200
WS1 DLFC 20.0 gpm for 1
V3190-250
WS1 DLFC 25.0 gpm for 1
2
V3765-01
WS3 DLFC HOUSING NPT
1
V3765BSPT-01
WS3 DLFC HOUSING BSPT
3
V3766
WS3 DLFC RETAINER
1 or 2
4
V3767
WS3 DLFC RETAINER COVER
1
5
V3768
WS3 DLFC RETAINER RING
1
6
V3769
O-RING 336
1 or 2
V3768 retainer ring position
if one V3766 is used.
V3768 retainer ring position
if two V3766 are used.
Positioning of V3767
into V3766
Interlock between two V3766’s
Larger hole for DLFC installation
B indicates BSPT
N indicates NPT
2
4
1
3
1
6
6
5
Assemblies are shipped without drain line
fl
ow control (DLFC) washers.
Assembly instructions:
1. Determine the desired
fl
ow rate. Select a combination of V3190-XXX’s to arrive at the desired
fl
ow rate.
2. Using a drill or punch remove the desired knockout(s) in V3766. Each V3766 retainer contains two types of knock
outs. The larger knockouts are removed to install a DLFC. If two V3766 retainers are needed remove the smaller
diameter knockout that lines up with the DLFC installed in the other retainer. One or two V3766 retainers may be
used. When using one V3766 retainer V3190-XXX must be installed in the center hole. When using two V3766
retainers a V3190-XXX must be installed in the center hole of one of the retainers and the center hole on the other
retainer must remain open.
3. Smooth hole(s).
4. Install appropriate size(s) of drain line
fl
ow control washers. Pay close attention to proper DLFC orientation.
5. Assemble. Each V3766 retainer must have a V3769 o-ring installed. One each of the V3767 retainer cover and V3768
retainer ring must be used whether one or two V3766 retainers are used. The positioning of the V3768 retainer ring
varies depending on the number of V3766 retainer(s) used. Properly orientate the V3766(s) in the direction of
fl
ow.
6. Properly orientate the complete assembly in the direction of
fl