User Display Settings
When the system is operating, several displays may be shown.
Pressing NEXT will alternate between the displays. One of the
displays is the current time of day. CAPACITY REMAINING
is the cubic meters that will be treated before the system goes
through a regeneration cycle. Pressing
▼
while in the Capacity
Remaining display will decrease the capacity remaining in .01 m
3
increments and will also increase the volume used impacting the
recorded values in Diagnostics Steps 3D, 4D and Valve History,
Step 5VH. DAYS TO A REGEN is the number of days left before
the system goes through a regeneration cycle. Pressing
▼
while
in this screen will temporarily or decrease the displayed value
by 1 day. Another display shows the current treated water flow
rate through the system. Contact information will be displayed
if it was edited. For concerns with phone number or banner text
displays, contact OEM for instructions. The fifth display will
show either DP or HOLD if the dP switch is closed. If the system
has called for a regeneration that will occur at the pre-set time
of regeneration, the words REGEN TODAY will alternate with
the header on the display. If a water meter is installed, the flow
indicator appears on the display when water is being treated (i.e.
water is flowing through the system).
Flow Indicator
DELAYED RINSE+FILL PENDING will be displayed whenever a zero-capacity tank has
transferred to an off-line state and is currently waiting to initiate the second portion of a
regeneration cycle. Viewed only when Delayed Rinse and Fill is set to ON.
REGEN PENDING will be displayed in Alternator Systems whenever a unit is waiting to
initiate the first cycle step of regeneration.
STAND BY will be displayed in Alternator Systems when a valve is in Standby state.